Summary of Contents for Lancaster GOLD LINE LER X FACTOR Series
Page 1
7-LERDAN-1.5BNM 7-LERDAN-2BNM Congratulations on purchasing your new Lancaster Water Softener. This unit is designed to give you many years of trouble free service. When installed in accordance with the following instructions and if given reasonable care, clear-soft water will be the result. For servicing and future inspection purposes, please file this booklet with your important documents.
TABLE OF CONTENTS Job Specifications ................................ 2 Components ................................2 Pre-Installation Review ..............................3 General Installation and Service Warnings ......................... 3 Bypass Valve Operation .............................. 4 General Installation Instructions ..........................5 Installation ................................... 6,7 Start-Up Instructions ..............................7 Set Time of Day ................................8 Adjust Days Between Backwash or Time of Backwash ....................
GENERAL INSTALLATION PRE-INSTALLATION AND SERVICE WARNINGS REVIEW WATER PRESSURE: A minimum of 20 psi water pressure The control valve, fitting assemblies and bypass valve are is required for backwash. Maximum 100 psi. CAUTION: the designed to accommodate minor plumbing misalignments filter cannot be subject to a vacuum due to loss of pressure but are not designed to support the weight of a system or (such as a water main break or submersible well pump check...
BYPASS VALVE The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance. The X-Factor bypass valve is particularly unique in the water treatment industry due to its versatility and state of the art design features.
GENERAL INSTALLATION INSTRUCTIONS (All electrical & plumbing should be done in accordance to all local codes) 1. Place filter in desired location close to water supply inlet, after pressure tank, and near a source for waste water, (utility sink, floor drain or sewer line).
INSTALLATION MINIMUM 10 FEET OF PIPE OUTSIDE BETWEEN WATER FILTER OUTLET WATER HEATER INLET LOCATE WATER FILTER CLOSE TO A DRAIN. AVOID OVERHEAD DRAIN LINES IF POSSIBLE TO COLD BYPASS PLUMBING PREVENT BACK PRESSURE ON THE SYSTEM. RECOMMENDED IF OVERHEAD DRAIN LINE IS USED AND EXCEEDS THERMAL EXPANSION BP2000 5 FEET ABOVE CONNECTION ON CONTROL VALVE...
START-UP INSTRUCTIONS As noted on page 3 General Installation Instructions, allow lighter weight mineral such as Carbon and Filter Ag to soak in water prior to start-up; recommend minimum 12 hours up to 24 hours for best results. Do not plug the transformer into the receptacle yet.
SET TIME OF DAY Current time of day needs to be entered during initial installation, and adjusted when daylight saving time begins or ends. If an extended power outage occurs and depletes the on-board non-rechargeable coin cell battery, when power resumes the time of day should be reset and battery replaced.
Battery Fully Seated Output Voltage 12 V AC Output Current 500 mA When replacing the battery, align Correct WS1TC & WS1.25 TC Manual Page 13 FRONT COVER AND DRIVE ASSEMBLY positives and push down to fully seat. Battery Battery replacement is Orientation 3 volt lithium coin cell type 2032.
Page 10
WS1 & WS1.25 Drawings & Service Manual WATER METER AND METER PLUG Drain Line – 3/4” Drawing No. Order No. Description Quantity H4615 Elbow Locking Clip Item No. Quantity Part No. Description PKP10TS8-BULK Polytube insert 5/8 Option V3192 WS1 Nut ¾ Drain Elbow Option V3158-01 WS1 Drain Elbow ¾...
Page 11
PARTS V3007 1” PVC Male NPT V3191-01 Vertical Elbow Assembly Adapter Assembly Standard Optional Item No. Part No. Description Item No. Part No. Description V3151 Nut 1” Quick Connect V3151 Nut 1” Quick Connect V3150 Split Ring V3150...
Page 12
OPTIONAL INSTALLATION FITTING ASSEMBLIES Order No: V3007-03 Order No: V3007-01 Order No: V3007-02 Description: Fitting ¾” Brass Sweat Assembly Description: Fitting ¾” & 1” PVC Solvent 90° Description: Fitting 1” Brass Sweat Assembly Assembly Drawing Drawing Order Order No. Description Quantity Description Quantity...
ACID NEUTRALIZERS (7-LXDAN-) REPLACEMENT MINERAL INSTRUCTIONS SERVICE INSTRUCTIONS REPLACEMENT MINERAL INSTRUCTIONS: Mineral used: Calcite. Acid Neutralizers raise the pH of acidic water. Calcite is a sacrificial mineral, dissolving in proportion to the acidity of the raw water. Calcite is self-limiting, i.e. it corrects Q7005 Dome Plug w/ o-ring pH only enough to reach a non-corrosive equilibrium.
SPECIFICATIONS ACID NEUTRALIZERS: Mineral used: Calcite. Acid Neutralizers raise the pH of acidic water. Calcite is a sacrificial mineral, dissolving in proportion to the acidity of the raw water. Calcite is self-limiting, i.e. it corrects pH only enough to reach a non-corrosive equilibrium. It does not overcorrect under normal conditions. Calcite will add hardness to the original hardness of the raw water.
TROUBLESHOOTING PROCEDURES PROBLEM POSSIBLE CAUSE SOLUTION a. Transformer unplugged a. Connect power 1. Timer does not display time of b. No electric power at outlet b. Repair outlet or use working outlet day. c. Defective transformer c. Replace transformer d. Defective PC board d.
Page 16
A DIVISION OF C-B TOOL CO. 1340 MANHEIM PIKE ● LANCASTER PA 17601-3196 ● TEL:717-397-3521 ● FAX: 717-392-0266 www.lancasterwatergroup.com ● E-mail: info@lancasterwatergroup.com 2/24 PAGE 16...
Need help?
Do you have a question about the GOLD LINE LER X FACTOR Series and is the answer not in the manual?
Questions and answers