Direct vent zero clearance gas fireplace heater (16 pages)
Summary of Contents for Empire Comfort Systems DVCD36FP30KP-4
Page 1
This Owner's Manual is provided and hosted by Appliance Factory Parts. EMPIRE DVCD36FP30KP-4 Owner's Manual Shop genuine replacement parts for EMPIRE DVCD36FP30KP-4 Find Your EMPIRE Fireplace Parts - Select From 656 Models -------- Manual continues below part list --------...
Page 2
Available Replacement Parts for EMPIRE DVCD36FP30KP-4 R7578 LP Valve Fits ADVD 42, 48, BVD 34, 36 R7577 Nat Valve Fits DVD 32, 36, 42, 48 R7611 Pilot LP Fits DVP, DVD R7612 Pilot Nat Fits DVP, DVD R3436 Remote Off, On Switch...
INSTALLATION INSTRUCTIONS DIRECT - VENT ZERO INSTALLER: CLEARANCE GAS FIREPLACE Leave this manual with the appliance. CONSUMER: HEATER MODEL SERIES: Retain this manual for future reference. MILLIVOLT (MV) DVCD(36,42)FP3(0,1)K(N,P)-4 WARNING INTERMITTENT PILOT (IP) FIRE OR EXPLOSION HAZARD DVCD(36,42)FP7(0,1)K(N,P)-4 Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
Installation and/or use of any component part not • The four corners of the fireplace onto non-combustible manufactured or approved by Empire Comfort Systems. material so that contact is made on all four corners of the bottom of the fireplace – such as on cinder blocks All correspondence should refer to complete Model Number, (where allowed by local codes).
CARTON CONTENTS & HARDWARE PACK Decorative Rock Rockwool Rockwool Quantity Supplied Index Number Description Location Fireplace Between carton caps Canopy Above window door Log Set Inside firebox Barrier Screen Mounted on fireplace Flex Line w/Shut-off Valve In envelope Decorative Rock Under log set Rockwool In envelope...
HOMEOWNER REFERENCE INFORMATION We recommend that you record the following information about your fireplace. Model Number: _____________________________ Date purchased: ________________________ Serial Number: _____________________________ Location of fireplace: _____________________ Dealer Name: ______________________________ Dealer Phone: _________________________ Notes: ______________________________________________________________________________ INTRODUCTION Fireplace Certification The information in this manual pertains to all models and gas control systems unless otherwise noted.
DVVK4RP GF24 thickness Stainless Steel DVVK4VP Vertical Vent Kit NOTICE: Empire Comfort Systems does not offer a mantel for DVVK4F Horizontal Flex Vent Kit (4-foot flex) this series of fireplaces. Horizontal round termination (wall thickness up DVVK4RE to 13-3/4 inches)
45° ELBOW THREE 90° ELBOWS) ROOF FLASHING 90° ELBOW Special venting components See Empire Comfort Systems Retail Price List for Duravent part numbers and pricing. CEILING FIRE STOP Special DV Vent Kits Available from Empire Comfort Systems Dealers WALL STRAP...
FIREPLACE DIMENSIONS REAR VENTING TOP VENTING LEFT VIEW RIGHT VIEW FRONT VIEW CORNER INSTALL Figure 3 Page 8 41394-0-0120...
Page 11
FIREPLACE DIMENSIONS DVCD36 DVCD42 INDEX DIMENSION DESCRIPTION LETTER Dimensions in Inches The maximum height of firebox face (excluding standoffs) 35-5/8 37-5/8 The maximum width of the firebox face (excluding nailing flanges) 37-9/16 43-9/16 The maximum depth of the firebox 17-3/4 17-3/4 The height of the firebox opening 27-1/2...
CLEARANCES Mantel Chart CLEARANCE TO COMBUSTIBLES DIM. IN INCHES CEILING Back Side Floor COMBUSTIBLES ALLOWED Top Stand-off WALL Top Framing Edge STUD 10” 41” MIN. 20 1/4” MIN. WALL 2" x 4" BOTTOM PLATE 10 1/4” FACING MIN. TOP OF CANOPY CANOPY 84”...
LOCATING FIREPLACE NOTICE: Island and room divider installation are possible as long as the horizontal portion of the vent system does not exceed 20 feet with a minimum vertical run of 8 feet. Refer to Venting Section (pages 16 - 27). Maintain a minimum 6-inch clearance to the perpendicular wall from the front edge of the fireplace.
GAS SUPPLY The gas pipeline can be brought in through left or right side of The use of the following gas connectors is recommended: the fireplace. Consult the current National Fuel Gas Code, ANSI — ANSI Z21.24 Appliance Connectors of Corrugated Metal Z223.1 CAN/CGA-B149 (.1 or .2) installation code.
Page 15
GAS SUPPLY (CONT’D) Installing a New Main Gas Supply Shut-off Valve (Check OUTLET PRESSURE INLET Local Code) PRESSURE Each appliance must have its own manual gas shut-off valve HI/LO REGULATOR located in the vicinity of the fireplace. Where none exists, or where its size or location is not adequate, contact your local authorized installer for replacement or relocation.
JUNCTION BOX WIRING (FOR OPTIONAL BLOWER) STANDARD MILLIVOLT VALVE MODELS CAUTION All wiring should be done by a qualified electrician and shall be in compliance with all local, city and state building codes. Before making the electrical connection, make sure that the main power supply is disconnected.
Page 17
INSTALLATION (CONT’D) Frame the Fireplace Opening Attach fireplace to frame using adjustable nailing flanges. Choose fireplace location. Set the nailing flange depth to suit the wall material Frame in fireplace opening with a plate across the top. It is (adjustable to 1/2 or 5/8 inch). important to allow for the finished fireplace face when setting the depth of the frame.
INSTALLATION (CONT’D) Install the Canopy Finishing Retrieve canopy from the opening above the glass door. Figure 7 on page 10 shows the minimum vertical and Place the canopy above the firebox as shown in Figure 21. corresponding maximum horizontal dimensions of mantels or NOTICE: Fireplace heat shield will rest on top of the combustion other combustible projections above the top front edge of the chamber inside of the open area between the top flue and...
Page 19
VENT PIPE CLEARANCE Vertical, 90° Elbow with Horizontal Termination OUTSIDE THIMBLE ASSEMBLY 3” (76mm) MINIMUM CLEARANCE TO COMBUSTIBLES 11” (297 mm) MIN. VENT CAP/ THIMBLE DVCD(32,36) 47 ½” (121 cm) WALL FIRESTOP TO BOTTOM OF UNIT DVCD42 9 1/8” 49 ½” EXTERIOR (232 mm) (126 cm)
Page 20
VENT PIPE CLEARANCE Vertical, 90° Elbow to Horizontal Out the Wall Corner Installation Horizontal, 45° Elbow to Horizontal Out the Wall “A” 90° ELBOW PIPE WALL FIRESTOP/ LENGTH THIMBLE “A” PIPE LENGTH VENT CAP VENT CAP “B” WALL FIRESTOP/ THIMBLE “C”...
VENTING FIREPLACE - TOP To Use the Vent Graph Venting Graph (Dimensions in Feet) Determine the height of the center of the horizontal vent pipe. TOP EXIT - VERTICAL AND HORIZONTAL TERMINATION Using this dimension on the Sidewall Vent Graph, locate the (DIMENSIONS IN FEET) point it intersects with the slanted graph line.
Page 22
Vinyl Soffit, Vinyl Ceiling, Vinyl Overhang Disclaimer Clearances are to heat resistant material (i.e. wood, metal). This does not include vinyl. Empire Comfort Systems will not be held responsible for heat damage caused from terminating under vinyl overhangs, vinyl ceilings or vinyl ventilated/unventilated soffits.
Page 23
VENTING FIREPLACE - TOP (CONT’D) Example of possible venting systems using two 90° elbows. V is listed as minimum vertical dimensions and H1 + H2 is listed as total of maximum horizontal dimensions. The maximum vertical and horizontal distances for two 90° elbows as shown in Figure 33 is 20 feet (6.1 m).
Page 24
VENTING FIREPLACE - TOP (CONT’D) Position the Fireplace 3’ If possible, position the fireplace so the direct vent termination will (914mm) be centered between two studs. This will avoid any extra framing. MAXIMUM HORIZONTAL All vent kit pipes should be assembled on the fireplace after the RUN WITH 90°...
Page 25
VENTING FIREPLACE - TOP (EXAMPLES) 24” MINIMUM CLEARANCE TO COMBUSTIBLES EXAMPLE H2 = 3ft, H3 = 1ft, 90° Elbow= 3 ft H2 + H3 = 4ft (90° + 90° + 90°) = 6ft* H2 + H3 + Elbows = 10ft V1 = 21ft H = 10ft V = 21ft *The first elbow does not count towards the total.
VENTING FIREPLACE - REAR To Use the Vent Graph Venting Graph (Dimensions in Feet) Determine the height of the center of the horizontal vent TOP EXIT- VERTICAL AND HORIZONTAL TERMINATION pipe. Using this dimension on the Sidewall Vent Graph, (DIMENSIONS IN FEET) locate the point it intersects with the slanted graph line.
Page 27
VENTING FIREPLACE - REAR (EXAMPLES) Maximum Length H1 Model (Dim. in inches) DVCD36 DVCD42 Figure 43 Figure 41 Example H2 = 4ft 2-(90° + 90°) = 6ft V1 = 12ft H = 10ft V = 12ft Figure 44 Maximum Length H1 Model (Dim.
REAR VENT CONVERSION Convert flue take-off to rear venting Install the flue collar assembly to the rear flue with four When switching out the flue and inlet vent collars to run #10 hex head screws removed in Step 1. horizontally off the rear vent, the following steps must be taken. Install the inlet vent collar to the rear of the fireplace with the Remove the inlet vent collar (eight #10 hex head screws) eight #10 hex head screws removed in Step 1.
Clearances are to heat resistant material (i.e. wood, metal). This supplier. does not include vinyl. Empire Comfort Systems will not be held responsible for heat damage caused from terminating under vinyl overhangs, vinyl ceilings or vinyl ventilated/unventilated soffits.
FRAMING AND FINISHING Install Support Brackets Install Firestops A horizontal pipe support MUST BE used for each 3 feet of Firestops are required for safety whenever the vent system passes horizontal run. Place the pipe supports around the pipe and nail through an interior wall, an exterior wall, or a ceiling.
Page 31
FRAMING AND FINISHING (CONT’D) Vertical Firestops Vertical runs require the use of one ceiling firestop at each ceiling hole through which the venting passes. Position a plumb bob directly over the center of the vertical vent component and mark the ceiling to establish the center point of the vent.
TERMINATION CLEARANCES Termination clearance for buildings with combustible and noncombustible exteriors. Figure 51 Vertical Sidewall Installations Important! Minimum clearance between vent pipes and combustible materials is 3 inches on top, and 1 inch on bottom and sides. Important! When vent termination exits through foundation less than 20 inches below siding outcrop, the vent pipe must extend outward so that the horizontal vent terminal is located flush to, or beyond the outcrop siding.
VINYL SOFFIT, VINYL CEILING, VINYL OVERHANG DISCLAIMER Clearances are to heat resistant material (i.e. wood, metal). This does not include vinyl. Empire Comfort Systems will not be held responsible for heat damage caused from terminating under vinyl overhangs, vinyl ceilings or vinyl ventilated/ unventilated soffits.
VERTICAL TERMINATION General Maintenance Determine Minimum Vent Height Above the Roof. Conduct an inspection of the venting system semi-annually. Locate and mark the center point of the vent pipe using a nail on Check any areas of the venting system exposed to the the underside of the roof.
Page 35
VERTICAL TERMINATION (CONT’D) Install the vertical inlet baffle 24” MINIMUM Place the vertical inlet baffle over the exterior of the air inlet CLEARANCE TO openings on the direct vent high wind vertical cap. COMBUSTIBLES; There are three sections of air openings on the exterior of NATURAL OR the air inlet pipe.
DVVK-4F FLEX VENT INSTRUCTIONS CAUTION SPACER Sharp edges. To avoid injuries, wear safety gloves when SPRINGS handling the flex vent components. The DVVK-4F FLEX VENT KIT includes the following components: • (1) Horizontal Termination Cap • (1) 4-foot section of Flex vent with spacers (4” flue/7” outer pipe) •...
Page 37
DVVK-4F FLEX VENT INSTRUCTIONS (CONT’D) Attach the Termination Cap to the outside of the house. Prior to making the vent connections, apply high temperature sealant (600 degree F min.) to the vent connections before securing with the band clamps provided. NOTE: the flue pipe end without the adapter is to be installed to the Termination Cap.
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS CAUTION Sharp edges. To avoid injuries, wear safety gloves when handling the vent components. Tools Needed for Installation: • Sheet metal snips • 5/16” nut driver • Phillips head screwdriver - #2 • High temperature sealant or furnace cement rated for continuous use at 600ºF minimum •...
Page 39
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (CONT’D) Remove outside mounting plate with tube attached from wall. Mark and cut the extra length of the 6-5/8 inch diameter tube from the opposite end. Do not crimp or enlarge tube. Attach the 4-inch diameter flue outlet tube onto the rigid venting system or directly to fireplace.
Page 40
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (CONT’D) Sealing 4-inch Diameter Flue Outlet Tube Follow correct option according to venting method. Connecting Directly to Fireplace If the air inlet and flue outlet tubes are to be connected directly to the unit (no rigid venting system is being used), then the gasket provided must be used to seal the 4-inch flue outlet tube.
LOG IDENTIFICATION FOR DVCD36 FIREPLACES Part Number Front View Top View Description Log A 28378 Log B 28379 Log C 28375 Log D 28374 Log E 28376 Log F 28377 41394-0-0120 Page 39...
LOG PLACEMENT FOR DVCD36 FIREPLACES This fireplace is supplied with a set of six ceramic fiber logs. Do Decorative Material Placement not handle these logs with your bare hands! Always wear gloves Position all of the logs before placing the decorative to prevent skin irritation from ceramic fibers.
Page 43
LOG PLACEMENT FOR DVCD36 FIREPLACES Align slot on back of Log A with burner bracket on left front of burner and push Log A toward the front. BURNER BRACKET 41394-0-0120 Page 41...
Page 44
LOG PLACEMENT FOR DVCD36 FIREPLACES Align slot on Log B with the burner bracket on the front right side of the burner. Push Log B towards the front. BURNER BRACKET Page 42 41394-0-0120...
Page 45
LOG PLACEMENT FOR DVCD36 FIREPLACES Align Log C slots with burner bracket on the lower left side of burner and slide log to the left until it stops BURNER BRACKET 41394-0-0120 Page 43...
Page 46
LOG PLACEMENT FOR DVCD36 FIREPLACES Align Log D with the left rear burner bracket, resting on the rear log support. Pull forward slightly to lock the log in place over the top rear burner bracket. BURNER BRACKET Page 44 41394-0-0120...
Page 47
LOG PLACEMENT FOR DVCD36 FIREPLACES Place Log E pin into Log C. Align the top pin of Log D with the hole in Log E. Ensure the lower divet of Log E is placed against the front of the grate. 41394-0-0120 Page 45...
Page 48
LOG PLACEMENT FOR DVCD36 FIREPLACES Place the pin on Log F into the front slot of Log C. The longest arm of the “Y” shape should angle down and rest where it will conseal the separation between Logs A and B. Page 46 41394-0-0120...
Page 49
LOG PLACEMENT FOR DVCD36 FIREPLACES Log placement is complete. 41394-0-0120 Page 47...
LOG IDENTIFICATION FOR DVCD42 FIREPLACES Part Front View Top View Description Number Log A 28386 Log B 28387 Log C 28382 Log D 28381 Log E 28383 Log F 28384 Log H 28385 Page 48 41394-0-0120...
LOG PLACEMENT FOR DVCD42 FIREPLACES This fireplace is supplied with a set of seven ceramic fiber logs. Do not handle these logs with your bare hands! Always wear gloves to prevent skin irritation from ceramic fibers. After handling the logs, wash your hands gently with soap and water to remove any trace of fibers.
Page 52
LOG PLACEMENT FOR DVCD42 FIREPLACES Align slot on back of Log A with burner bracket on left front of burner and push Log A toward the front. BURNER BRACKET Page 50 41394-0-0120...
Page 53
LOG PLACEMENT FOR DVCD42 FIREPLACES Align slot on Log B with the burner bracket on the front right side of the burner. Push Log B towards the front. BURNER BRACKET 41394-0-0120 Page 51...
Page 54
LOG PLACEMENT FOR DVCD42 FIREPLACES Align Log C slots with burner bracket on the lower left side of burner and slide log to the left until it stops BURNER BRACKET Page 52 41394-0-0120...
Page 55
LOG PLACEMENT FOR DVCD42 FIREPLACES Align the slot on Log D with the burner bracket on the left side of the burner and pull Log D forward. BURNER BRACKET 41394-0-0120 Page 53...
Page 56
LOG PLACEMENT FOR DVCD42 FIREPLACES Place Log E onto the pin on the far right of Log D. It should rest on the flat edge of Log C and the flat section of Log B. Page 54 41394-0-0120...
Page 57
LOG PLACEMENT FOR DVCD42 FIREPLACES Place Log F onto the center pin of Log C. The “Y” shape should appear to be upside down with the two arms placed against the grate tangs to help hold Log C upright. 41394-0-0120 Page 55...
Page 58
LOG PLACEMENT FOR DVCD42 FIREPLACES Place Log G onto the upper left pin of Log D. The longest arm should lock into the small notch at the top back of Log A so that Log G holds the back Log (D) upright. Page 56 41394-0-0120...
Page 59
LOG PLACEMENT FOR DVCD42 FIREPLACES Log placement is complete. 41394-0-0120 Page 57...
MILLIVOLT OPERATING INSTRUCTIONS MILLIVOLT SYSTEM - “PILOT ON DEMAND” INITIAL LIGHTING • In the “Pilot On Demand” mode, the pilot remains ON Upon completing the gas line or turning the gas valve on after continuously even when the burner is turned OFF. The pilot it has been in the “OFF”...
Page 61
MILLIVOLT OPERATING INSTRUCTIONS CHECK SYSTEM OPERATION The millivolt system and all individual components may be checked with a millivolt meter, 0-1000 MV range. It is important to use wire of a gauge proper for the length of the wire: Recommended Wire Gauges Maximum Length Wire (dimensions in feet)
MILLIVOLT STANDING PILOT WIRING DIAGRAM Figure 75 If any of the original wire supplied with this fireplace must CAUTION be replaced, it must be replaced with equivalent gauge and Label all wires prior to disconnection when servicing controls. temperature rated wire. Wiring errors can cause improper and dangerous operation.
MILLIVOLT STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This fireplace has a pilot which must be lighted by hand. C.
MILLIVOLT STANDING PILOT TROUBLESHOOTING With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken.
IPI ELECTRONIC SYSTEM OPERATING INSTRUCTIONS 5.25 VDC ELECTRONIC CONTROL VALVE NOTICE: The gas control has a manual HI/LO flame adjustment knob (regulator) that allows you to increase or decrease the The electronic control valve system includes the ability to switch height of the burner flame.
IPI ELECTRONIC SYSTEM WIRING DIAGRAM CPI/IPI SWITCH ON/OFF REMOTE RECEIVER PILOT SWITCH (OPTIONAL) + ON REMOTE - OFF GAS CONTROL VALVE (GND) AC/DC POWER ADAPTOR BATTERY ELECTRONIC CONTROL MODULE BACK-UP BATTERY HOLDER Figure 77 If any of the original wire supplied with this fireplace must be replaced, it must be replaced with equivalent gauge and temperature rated wire.
INTERMITTENT PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This fireplace has a pilot which can be lighted with the C.
INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING Brief Description of the Components The gas valve is fitted with a manual HI/LO knob to allow for manual modulation of the gas outlet pressure to the fireplace burner. The controls are designed to be used with either Propane or Natural Gas and can be converted by use of an OEM supplied conversion kit.
Page 69
INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING PROBLEM OBSERVED POSSIBLE CAUSE CORRECTIVE MEASURE WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Gas odor during setup Gas Leak Do not touch any electrical switch; do not use any phone in your building. Leave the building immediately.
Page 70
INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING Flame sensor dirty Clean pilot sensor Low gas pressure Check gas supply pressure Not enough fresh air for pilot Open door or window - ventilate Clogged or dirty burner ports Clean burner ports Move (optional) remote away from fire- (For fireplace equipped with optional ther- Burner &...
MAINTENANCE & SERVICE - QUALIFIED SERVICE PERSON PLEASE NOTE Install the Logs It is normal for fireplaces fabricated of steel to give off some The position of the logs is critical to the safe and clean operation expansion and/or contraction noise during the start up or cool of this fireplace.
Page 72
MAINTENANCE & SERVICE - QUALIFIED SERVICE PERSON Barrier Screen and Glass Door Removal Grasp the bottom edge of the glass frame and carefully pull Grasp the sides of the screen at the bottom and carefully lift the bottom of the glass away from the fireplace. it up and out.
Page 73
MAINTENANCE & SERVICE - QUALIFIED SERVICE PERSON NOTICE: If improperly placed, the gasket will prevent the bottom FOR THE INSTALLER of the glass frame from contacting the fireplace. Maintenance Precautions Find the two glass frame clamps on the bottom of the Installation and repair should be done by a qualified service fireplace.
DVCD36FP(3,7) PARTS LIST PART NUMBER PART NUMBER INDEX INDEX DESCRIPTION DESCRIPTION MV (FP3) IP (FP7) MV (FP3) IP (FP7) R7654 R7654 Flue Insulation R2522 ON/OFF Switch 17425 17425 Flue Insulation Retainer R11127 Control Module R7566 R7566 Inlet Vent Adaptor 36177 34109 Valve Heat Shield 17162...
DVCD36FP(3,7) PARTS VIEW INTERMITTENT PILOT BURNER ASSEMBLY MILLIVOLT BURNER ASSEMBLY WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in property damage or personal injury. 41394-0-0120 Page 73...
DVCD42FP(3,7) PARTS LIST PART NUMBER PART NUMBER INDEX INDEX DESCRIPTION DESCRIPTION MV (FP3) IP (FP7) MV (FP3) IP (FP7) R7654 R7654 Flue Insulation R10947 Wire Assembly 17425 17425 Flue Insulation Retainer R11122 Battery Holder R7566 R7566 Inlet Vent Adaptor R2522 ON/OFF Switch R11127 Control Module...
DVCD42FP(3,7) PARTS VIEW INTERMITTENT PILOT BURNER ASSEMBLY MILLIVOLT BURNER ASSEMBLY WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in property damage or personal injury. 41394-0-0120 Page 75...
IMPORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED WARNING 1. “Due to high temperatures, the appliance should be 6. “Clothing or other flammable material should not be located out of traffic and away from furniture and placed on or near the appliance.”...
SAFETY INFORMATION FOR USERS OF PROPANE GAS Propane is a flammable gas which can cause fires and SOME POINTS TO REMEMBER explosions. In its natural state, propane is odorless and • Learn to recognize the odor of Propane Gas. Your local colorless.
REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment 3. SIGNAGE. A metal or plastic identification plate installed in every dwelling, building or structure used in shall be permanently mounted to the exterior of the whole or in part for residential purposes, including those building at a minimum height of eight feet above grade owned or operated by the Commonwealth and where the directly in line with the exhaust vent terminal for the...
This list changes from time to time. For the current list, please click on the Master Parts button at www.empirecomfort.com. Please NOTICE: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equipment repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems. Dey Distributing F.
WARRANTY Empire Comfort Systems Inc. warranties this hearth product to be free from defects at the time of purchase and for the periods specified below. This warranty applies to the original purchaser only and is not transferable. All warranty repairs must be accomplished by a qualified gas appliance technician.
APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes 41394-0-0120 Page 81...
Page 84
APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes Page 82 41394-0-0120...
Page 85
APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes 41394-0-0120 Page 83...
Page 86
Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 84 41394-0-0120...
This manual is also suitable for:
Dvcd fp7 k-4 seriesDvcd36Dvcd42Dvcd fp3 k-4 series
Need help?
Do you have a question about the DVCD36FP30KP-4 and is the answer not in the manual?
Questions and answers