Leica Microsystems PROVEO 8x User Manual

Heads-up digital visualization system

Advertisement

Quick Links

From Eye to Insight
PROVEO 8x
Heads-up Digital Visualization System
User Manual
10 735 165 version 00
Date of issue: 2024-10-10
0123

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROVEO 8x and is the answer not in the manual?

Questions and answers

Summary of Contents for Leica Microsystems PROVEO 8x

  • Page 1 From Eye to Insight PROVEO 8x Heads-up Digital Visualization System User Manual 10 735 165 version 00 Date of issue: 2024-10-10 0123...
  • Page 2 PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 3: Table Of Contents

    Position the heads-up monitor What to do if..? Maintenance instructions Disposal Technical data Ambient conditions Electrical data Electromagnetic compatibility (EMC) Standards fulfilled Annex 10.1 Checklist before the operation PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 4 PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 5: Introduction

    • It is available on the floor stand. • The floor stand is for the positioning of the PROVEO 8x in the Nomenclature room. • The PROVEO 8x surgical microscope is subject to special In the following, the term "heads-up monitor"...
  • Page 6: Limitations Of Use

    3D, switch back to binocular tubes. Use only compatible 3D glasses provided by Leica Microsystems. Do not use 3D glasses on the 2D monitor.. PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 7: Mri Safety Information

    Follow the instructions in the user manual for those accessories. • Modifications, installations to or service on the PROVEO 8x surgical microscope may be carried out only by technicians who PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 8 Retina Protection 16.5 Function Activated Coaxial Red Reflex illumination Light setting Maximum exposure time according to 1) [min.] 50 % 100 % Retina Protection Function Activated PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 9: Proveo 8X Heads-Up Digital Visualization System

    PROVEO 8x Heads-up Digital Visualization System PROVEO 8x Heads-up Digital Visualization System The option for performing heads-up ophthalmology is based on the system combination of compatible monitors with PROVEO 8x provided by Leica Microsystems. The PROVEO 8x Heads-up Digital Visualization System provides ergonomic advantages as the user can maintain an upright posture while observing the surgical field.
  • Page 10: Heads-Up Monitor

    • Do not use the 3D glasses as sunglasses. • Do not touch or scratch the lens surface of the 3D glasses. • Do not leave the 3D glasses near heating equipment. PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 11 Secure the power cable with plate (1) and plastic spacers (2) as illustrated. Connect an SDI cable of the heads-up monitor to port "SDI 3D" of PROVEO 8x (3). PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 12: Preparation Before Surgery

    The heads-up monitor shall be positioned in a way that the surgeon has an unobstructed view and that the surface of the heads-up monitor is perpendicular to the line of sight of the surgeon. PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 13 Superior and temporal working position with a 32" monitor and cart 1. Microscope 2. Phaco-vitrectomy system 3. Heads-up monitor and cart 4. Main surgeon 5. Sterile nurse 6. Assistant surgeon PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 14 55" monitor) or 32° (B, for 32" monitor) from the minimum viewing distance (A). Note Image quality and depth perception may be affected when viewing the monitor outside of the viewing distance and angle. PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 15: What To Do If

    Rotate and tilt the monitor so that the surgeon’s to the monitor. line of sight is perpendicular to the monitor surface (see chapter 5.2, page 10). PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 16: Maintenance Instructions

    • Halogen-splitting compounds • Strong organic acids • Oxygen-splitting compounds. Follow the disinfectant manufacturer's instructions. • We recommend concluding a service contract with Leica Service. PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 17: Technical Data

    • The Medical Division, within Leica Microsystems (Schweiz) AG, holds the management system certificate for the international standard ISO 13485 relating to quality management and quality assurance. PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...
  • Page 18: 10 Annex

    Connect an SDI cable of the heads-up monitor to port "SDI to PROVEO 8x 3D" of PROVEO 8x. Check the system performance. Position the heads-up monitor. PROVEO 8x Heads-up Digital Visualization System / Ref. 10 735 165 / Version 00...