Summary of Contents for Jinko Solar PV-JK03M Series
Page 1
Installation Manual for PV-JK03M Series Cable Connector...
Page 2
Abbreviations A: Amper. Unit of current. AC: Alternating Current. AWG: American Wire Gauge. DC: Direct Current. e.g.: exempli gratia (for example). IEC: International Electrotechnical Commission. IP: Ingress Protection. mm: Millimeter. Unit of length. mΩ: Mili ohms. Unit of resistance. m-PPE: Modified Polyphenylene Ether. N: Newtons.
3. Technical Data PV-JK03M / xy (Plug+Socket) (IEC) Type Name or Model Number PV-JK03M Series (PV-JK03M-F/xyab and PV- JK03M-M/xyab) (UL) 1000V DC / 1500V DC (IEC) Rated Voltage 1000V DC / 1500V DC (UL) 6000 V (1000 V DC) Rated Insulation Test Voltage 8000 V (1500 V DC) 30 A (2.5 mm²...
4. Tools Instruction Stripping Tool JKT-01 The Stripping Tool-JKT-01 (Figure 2) is applicable to 2.5 mm² (14 AWG), 4.0 mm² (12 AWG) and 6.0 mm² (10 AWG) cables. There is one stripping tool JKT-01 per tool set. Function: Cutting the wire insulation (exposing the copper wire). Figure 2.
Assembly Tool JKT-03 and Universal Tool JKT-04 There are two Assembly Tool -JKT-03 per tool set, and one Universal Tool JKT-04 per tool set (Figure 4). Function: Assembling and disassembling connectors. Figure 4. Assembly Tool JKT-03 and Universal Tool JKT-04.
5. Installation Instruction Cable Preparation a) According to different specifications of cables, please select the appropriate configuration from Table 4: Conductor cross section Connector configuration For TÜV For UL PV-JK03M / xA PV-JK03M / xAab PV-JK03M / xB PV-JK03M / xBab PV-JK03M / xC PV-JK03M / xCab PV-JK03M / xD...
Figure 7. Figure 6. Crimping 5.2.1 Crimping Tools a) When crimping with specified crimping tools (e.g. JKT-02), insert striped cable into contact barrel and ensure all conductor strands are captured in the contact barrel. Crimp contact barrel by using the corresponding crimping die (see below pictures from Figure 8 to Figure 12). Check whether the crimping is firm after the crimping was completed (Figure 13).
Page 11
Figure 8. Figure 9. Figure 10. d) Insert the stripped wire into the male/female terminal until the cable insulation touches the opening of the male/female terminal. Press the crimping tool completely (see Figure 11 and Figure 12). e) Be sure the crimping is complete and fixed (Figure 13). Figure 11.
Page 12
Technical requirement Cross section specification 12AWG / 4mm² 10AWG / 6mm² Crimp Height 2.30±0.20 mm 2.60±0.20 mm Crimp Width 4.00±0.10 mm 4.25±0.10 mm Measurable Crimp Width 1.0*CB≤CBm≤1.1*CB 1.0*CB≤CBm≤1.1*CB Crimp face Ends D ≤ 0.35 mm D ≤ 0.35 mm Burr Height GH ≤...
e) Crimping Tool drawing only for 10 AWG/6 mm cable, for reference (Figure 17 and Figure 18). Figure 17. Figure 18. Male/Female Terminals Installation a) Insert the crimped male or female terminal into corresponding male or female cable connector until they engage (Figure 19). Gently pull the wire to check that the metal part has engaged (Figure 20).
Page 14
Figure 21. Figure 22. Conductor cross section Tightening torque 2.0-2.5 2.0-2.5 2.0-2.5 3.5-4.0 Table 7. Tightening torque. d) After tightening the gland nut, insert the female connector of the cable into the male connector of the cable until they engage (Figure 23). Check whether the connectors have locked correctly (Figure 24) or not (Figure 24) by pulling them slightly.
Disconnecting Cable Connector a) Insert the forks of a universal tool, such as the JKT-04, into the cable connector buckle (Figure 26). b) Pull the connector with both hands (Figure 26) and separate the female connector from the male connector (Figure 26). Figure 26.
Installation Warning a) If non-specified tools or procedures are used, or connections are not prepared and assembled during installation as Jinko described, the safety and technical data on products are not guaranteed. b) During the transportation and storage, there should be no excessive pressure, impact and other acts of damaging the product.
Need help?
Do you have a question about the PV-JK03M Series and is the answer not in the manual?