  • Page 1 CS-302M Wired professional Conference Discussion System...
  • Page 2: Table Of Contents

    Introduction 04 Conference Unit Performance Feature 05 Packing List Thank you for choosing a RELACART wired professional conference discussion system. You 06 Host Function Introduction have joined thousands of other satisfied customers. Our years of professional experience 07 Microphone Unit Function Introduction P 10 of design and manufacturing to ensure our products’...
  • Page 3: Safety Operation And Notice

    ” indicates that dangerous voltage constituting a risk of electric shock is present within this unit. 21 All Relacart products will be afforded one year free maintenance except for man-made damage, such as: — the device is damaged by man-made factors.
  • Page 4: System Performance Feature

    System Performance Feature Conference Unit Performance Feature number of speaker, etc. cameras, compatible with VISCA, PELCO-D, PELCO-P 3 kinds of camera control code protocol. microphone pickup operation can be controlled, and the microphone LED can display the working status. SDI supports HDcctv1.0, HD-SDI (ST292), 3G-SDI (ST424) and SD-SDI (259). minimizes the effects of overly long connecting cables.
  • Page 5: Packing List

    Packing List Host Function Introduction Wireless conference system main controller * 1 1 meter audio cable * 1 Power cable * 1 Quick connector(female) * 2 9P aviation socket extension line or 10m network cable * 1 Rack mount kit (including screws) * 1set 9P aviation socket terminals or three-way matching Simple operation manual * 1 terminal * 1...
  • Page 6: Microphone Unit Function Introduction P

    Microphone Unit Function Introduction Female Ethernet port connection port: It can be connected to the CS-501CD or RS-361CD conference unit 9-pin aviation connection microphone through a network cable. It can be used with the auxiliary power supply EXP-124W. A total of 110 conference units can be connected.
  • Page 7 Network cable to connect the microphone sensitivity, and good long-distance pickup effect. (CS-501C Chairman unit) (CS-501D Delegate Unit) Working status indicator: The light is off when muted, the light is on when speaking, the light flashes when waiting for the application. Monitor Speaker: The voice signal input from the chairman or delegate unit and the central unit is output from this speaker.
  • Page 8: Conference System Repeater Function Introduction

    Conference System Repeater function introduction EXP-124 Repeater (Rear view) EXP-124W Repeater (Rear view) (RS-361C Chairman unit) (RS-361D Delegate Unit) Top view Top view EXP-124 Repeater (Front) EXP-124W Repeater (Front) Conjoined capsule: High-quality condenser microphone provides clear and full sound quality, high sensitivity, and good long-distance pickup effect.
  • Page 9: Setup And Operation

    (The chairman unit is not limited) to keep the total number of open speaking units. A. Startup main interface After turn on the power switch, the CS-302M main controller starts searching for online microphone VIDEO FIFO...
  • Page 10 Limit Times: Allow maximum 5 speaking units, and can set the microphone to open 1min to 100 min, when the limited VIDEO REQUEST 0 0 8 CONFERENCE SYSTEM time is reach, subsequent microphone speaks. (The chairman unit is not limited) When the number of microphone Appli...
  • Page 11 C o n f . M o d e Set Camera Pos scroll through the menu to select the device coordinate setting, and then press “ENTER” to enter the next level. VideoTrack System Conection Track Device Main Menu You can select “000” and other machine to start. Complete the automatic video tracking settings of all System Setup Camera Protocol conference units;...
  • Page 12 Touch the MENU button on the host panel to enter the video tracking setting selection menu, press ” to scroll through the menu to select the camera protocol, and then press ENTER to enter the next level “ ” -10dB Volume Main volume to select 1-4 cameras to work.
  • Page 13 System Conection Language Address System Setup System Setup Main Menu Setup Default Save Success √ Reset System information Key Lock scroll through the menu to select the language setting, and then press “ENTER” to enter the next level of language selection. Setup Save Success √...
  • Page 14: Camera Tracking Operation P

    Camera tracking operation 1. Connect the camera and projector equipment to the CS-302 system. The CS-302 host will enter the main menu, System information and select Video Track Set Set Camera Pos Track Device Camera Protocol Cameras Number Select Information, the system software version information is displayed. Compatible camera protocols and the number of cameras used.
  • Page 15 Function menu architecture diagram 002 003 Conf. Setup FIFO Camera Camera Pos Conf.Mode selection Speaker Number Limit Times Request Voice Activation P: 0° T : 0° Camera Pos Z: 1 onnection Set Camera Pos Track Device Visca 3 Address 000 is the default preset position. After confirming that each conference unit completes the video “...
  • Page 16: 1 System Application Connection Diagram P

    System application connection diagram 9P Aviation Socket Terminals CS-302M Network cable White three-way matching terminal White three-way Network matching terminal cable Recorder Projector Central control system 9P Aviation Socket Terminals Mixer Control line CAMERA NET Speaker Amplifier Speaker Camera...
  • Page 17: Technical Specifications

    Technical Specifications CS-302 System Technical Specifications CS 302M Technical Specifications Frequency response: 50Hz- Chassis specifications: EIA Standard 1U Supply voltage: 110-240V AC, 50/60Hz Total Harmonic Distortion: <0.1% (f=1KHz) Static power consumption: 9.25W Dynamic range: >100dB Rated power: 75W/24V Connecting cable: Anti-detached 9 core shielded cable Cat5 ype B network cable Maximum power: 100W/24V Connection Mode: Hand in hand XLR balances maximum output level: -10.2dBu...
  • Page 18 CS 302C D Technical Specifications CS-501C D Technical Specifications RS-361C/D Technical Specifications EXP-124 Technical Specifications Polar pattern: Cardioid Condenser Polar pattern: Cardioid Conderser Polar pattern: Cardioid Conderser Model: EXP-124 Frequency response: 50Hz-2 KHz Frequency response: 50Hz-2 KHz Power supply(AC): 110-240V, 50/60Hz Sensitivity: -25dB +/-3dB (0dB=1V/Pa, f=1Kz) Sensitivity: Sensitivity:-28dB +/-3dB(0dB=1V/Pa, f=1Kz)