<Disassembly and Reassembly Notes>
1.
Bracket Holder Plate removal
① Disconnect the lead wires from the Cover Lock Plate. (Soldered at one location)
② Push on the back side of the Cover Lock Plate. (Fig. 017)
③ Remove the Bracket Holder Plate.
NOTE

:Attaching the Bracket Holder Plate
・ Pull the Cover Lock Plate until you hear a "click" to fix the Bracket Holder Plate in
place.
2.
PCB Ass'y (A) removal
① Remove the PC Terminal Cap and the Bracket Holder Cap.
② Detach the PCB Ass'y (A). (Screws x 5)
NOTE

:Reassembling the PCB Ass'y (A)
・ Install the PCB Ass'y (A) by inserting the top side of it into the Rear Cover Ass'y.
(Fig. 018)
Fig. 017 Cover Lock Plate
Fig. 018 PCB Ass'y (A)