TechnipFMC Proline 300 Modbus RS485 Brief Operating Instructions

Transmitter with coriolis sensor

Advertisement

Quick Links

KA01311D/06/EN/01.17
71376076
Products
Brief Operating Instructions
Proline 300
Modbus RS485
Transmitter with Coriolis sensor
These instructions are Brief Operating Instructions; they are
not a substitute for the Operating Instructions pertaining to
the device.
Transmitter Brief Operating Instructions
Contain information about the transmitter.
Sensor Brief Operating Instructions →  3
Solutions
Services

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline 300 Modbus RS485 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TechnipFMC Proline 300 Modbus RS485

  • Page 1 Products Solutions Services KA01311D/06/EN/01.17 71376076 Brief Operating Instructions Proline 300 Modbus RS485 Transmitter with Coriolis sensor These instructions are Brief Operating Instructions; they are not a substitute for the Operating Instructions pertaining to the device. Transmitter Brief Operating Instructions Contain information about the transmitter. Sensor Brief Operating Instructions →...
  • Page 2 Proline 300 Modbus RS485 Order code: XXXXX-XXXXXX Ser. no.: XXXXXXXXXXXX Ext. ord. cd.: XXX.XXXX.XX Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555 Endress+Hauser...
  • Page 3 Proline 300 Modbus RS485 Brief Operating Instructions for the device Brief Operating Instructions for the device The device consists of a transmitter and a sensor. The process of commissioning these two components is described in two separate manuals: • Sensor Brief Operating Instructions •...
  • Page 4: Table Of Contents

    Table of contents Proline 300 Modbus RS485 Table of contents Document information ............5 Symbols used .
  • Page 5: Document Information

    Proline 300 Modbus RS485 Document information Document information Symbols used 1.1.1 Safety symbols Symbol Meaning DANGER! DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in WARNING serious or fatal injury.
  • Page 6 Document information Proline 300 Modbus RS485 Symbol Meaning Protective Earth (PE) A terminal which must be connected to ground prior to establishing any other connections. The ground terminals are situated inside and outside the device: • Inner ground terminal: Connects the protectiv earth to the mains supply.
  • Page 7: Basic Safety Instructions

    Proline 300 Modbus RS485 Basic safety instructions Basic safety instructions Requirements for the personnel The personnel must fulfill the following requirements for its tasks: ‣ Trained, qualified specialists must have a relevant qualification for this specific function and task. ‣...
  • Page 8: Workplace Safety

    Basic safety instructions Proline 300 Modbus RS485 NOTICE Verification for borderline cases: ‣ For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability as minute changes in the temperature, concentration or level of contamination in the process can alter the corrosion resistance properties.
  • Page 9: Security

    Proline 300 Modbus RS485 Basic safety instructions IT security We only provide a warranty if the device is installed and used as described in the Operating Instructions. The device is equipped with security mechanisms to protect it against any inadvertent changes to the device settings.
  • Page 10: Product Description

    Product description Proline 300 Modbus RS485 Product description The device consists of a Proline 300 transmitter and a Proline Promass or Cubemass Coriolis sensor. The device is available as a compact version: The transmitter and sensor form a mechanical unit.
  • Page 11: Installation

    Proline 300 Modbus RS485 Installation Installation For detailed information about mounting the sensor, see the Sensor Brief Operating Instructions →  3 Turning the transmitter housing To provide easier access to the connection compartment or display module, the transmitter housing can be turned.
  • Page 12: Turning The Display Module

    Installation Proline 300 Modbus RS485 Turning the display module The display module can be turned to optimize display readability and operability. – – – 3 mm A0030035 Depending on the device version: Loosen the securing clamp of the connection compartment cover.
  • Page 13: Cover Locking

    Proline 300 Modbus RS485 Installation Cover locking NOTICE Order code "Housing", option L "Cast, stainless": The covers of the transmitter housing are provided with a borehole to lock the cover. The cover can be locked using screws and a chain or cable provided by the customer.
  • Page 14: Electrical Connection

    Electrical connection Proline 300 Modbus RS485 Electrical connection NOTICE The measuring device does not have an internal circuit breaker. ‣ For this reason, assign the measuring device a switch or power-circuit breaker so that the power supply line can be easily disconnected from the mains.
  • Page 15 Proline 300 Modbus RS485 Electrical connection Signal cable Modbus RS485 The EIA/TIA-485 standard specifies two types of cable (A and B) for the bus line which can be used for every transmission rate. Cable type A is recommended. For detailed information about the specification of the connecting cable, see the Operating Instructions for the device.
  • Page 16 Electrical connection Proline 300 Modbus RS485 Standard cable - customer-specific cable No cable is supplied, and it must be provided by the customer (up to max. 300 m (1 000 ft)) for the following order option: Order code for DKX001: Order code 040 for "Cable", option 1 "None, provided by customer, max 300 m"...
  • Page 17: Connecting The Measuring Device

    Proline 300 Modbus RS485 Electrical connection 5.1.3 Terminal assignment Transmitter: supply voltage, input/outputs Supply voltage Input/output 1 Input/output 2 Input/output 3 1 (+) 2 (–) 26 (B) 27 (A) 24 (+) 25 (–) 22 (+) 23 (–) Device-specific terminal assignment: adhesive label in terminal cover.
  • Page 18: Connecting The Transmitter

    Electrical connection Proline 300 Modbus RS485 5.2.1 Connecting the transmitter A0026781 Terminal connection for supply voltage Terminal connection for signal transmission, input/output Terminal connection for signal transmission, input/output or terminal connection for network connection via service interface (CDI-RJ45); optional: connection for external WLAN antenna or...
  • Page 19 Proline 300 Modbus RS485 Electrical connection N ic N ic t e r t e r e r g ö f f e r g ö f f iz e iz e t e n t e n r ir...
  • Page 20 Electrical connection Proline 300 Modbus RS485 22 mm 24 mm – A0029816 10. Connect the cable in accordance with the terminal assignment .  Signal cable terminal assignment: The device-specific terminal assignment is documented on an adhesive label in the terminal cover.
  • Page 21 Proline 300 Modbus RS485 Electrical connection Removing a cable 3 (0.12) A0029598  1 Engineering unit mm (in) To remove a cable from the terminal, use a flat-blade screwdriver to push the slot between the two terminal holes while simultaneously pulling the cable end out of the terminal.
  • Page 22: Ensuring Potential Equalization

    Electrical connection Proline 300 Modbus RS485 5.2.2 Connecting the remote display and operating module DKX001 The remote display and operating module DKX001 is available as an optional extra . • The remote display and operating module DKX001 is only available for the following housing version: order code for "Housing": option A "Aluminum, coated"...
  • Page 23: Hardware Settings

    Proline 300 Modbus RS485 Electrical connection Hardware settings 5.4.1 Setting the device address The device address must always be configured for a Modbus slave. The valid device addresses are in the range from 1 to 247. Each address may only be assigned once in a Modbus RS485 network.
  • Page 24: Ensuring The Degree Of Protection

    Electrical connection Proline 300 Modbus RS485 5.4.2 Enabling the terminating resistor To avoid incorrect communication transmission caused by impedance mismatch, terminate the Modbus RS485 cable correctly at the start and end of the bus segment. ‣ A0029632 Switch DIP switch No. 3 to On.
  • Page 25: Post-Connection Check

    Proline 300 Modbus RS485 Electrical connection Post-connection check Are cables or the device undamaged (visual inspection)?  Do the cables used meet the requirements?  Do the cables have adequate strain relief?  Are all the cable glands installed, firmly tightened and leak-tight? Cable run with "water trap" →  24 ? ...
  • Page 26: Operation Options

    Operation options Proline 300 Modbus RS485 Operation options Overview of operation options A0030213 Local operation via display module Computer with Web browser (e.g. Internet Explorer) or with operating tool (e.g. FieldCare, DeviceCare, AMS Device Manager, SIMATIC PDM) Mobile handheld terminal with SmartBlue App Control system (e.g.
  • Page 27: Structure And Function Of The Operating Menu

    Proline 300 Modbus RS485 Operation options Structure and function of the operating menu 6.2.1 Structure of the operating menu Operating menu for operators and maintenances Language Operation task-oriented Setup Diagnostics Operating menu for experts Expert function-oriented A0014058-EN  2 Schematic structure of the operating menu 6.2.2...
  • Page 28: Access To The Operating Menu Via The Local Display

    Operation options Proline 300 Modbus RS485 Access to the operating menu via the local display X X X X X X 19.184 mA 12.5 X X X X X X Language 20.50 Ã English Deutsch Español Français Xxxxxxx A B C D E F G H I J K M N O P Q R S T U V W +0.000 Xx...
  • Page 29: Operational Display

    Proline 300 Modbus RS485 Operation options 6.3.1 Operational display Explanatory symbols for the measured value Status area • Depends on the device version, e.g.: The following symbols appear in the status area of the – : Volume flow operational display at the top right: –...
  • Page 30: Operating Elements

    Operation options Proline 300 Modbus RS485 Numeric editor Confirms selection. Moves the input position one position to the left. Exits the input without applying the changes. Inserts decimal separator at the input position. Inserts minus sign at the input position.
  • Page 31: Access To The Operating Menu Via The Operating Tool

    Proline 300 Modbus RS485 System integration Keys and meaning Reduces the contrast (brighter setting). Plus/Enter key combination (press and hold down the keys simultaneously) Increases the contrast (darker setting). Minus/Plus/Enter key combination (press the keys simultaneously) For operational display:Enables or disables the keypad lock.
  • Page 32: Commissioning

    Commissioning Proline 300 Modbus RS485 Commissioning Function check Before commissioning the measuring device: ‣ Make sure that the post-installation and post-connection checks have been performed. • "Post-installation check" checklist →  13 • "Post-connection check" checklist →  25 Setting the operating language...
  • Page 33: Configuring The Measuring Device

    Proline 300 Modbus RS485 Commissioning Configuring the measuring device The Setup menu with its submenus and guided wizards is used for fast commissioning of the device. They contain all the parameters required for configuration, such as for measurement or communication.
  • Page 34: Diagnostic Information

    Diagnostic information Proline 300 Modbus RS485 Diagnostic information Faults detected by the self-monitoring system of the measuring device are displayed as a diagnostic message in alternation with the operational display. The message about remedial measures can be called up from the diagnostic message, and contains important information on the fault.
  • Page 36 www.addresses.endress.com...