Proline 300 HART
Transmitter with Coriolis Sensor
Brief Operating Instructions Manual
KA01364O/06/EN/02.19
71454942
Brief Operating Instructions
Proline 300
HART
Transmitter with Coriolis sensor
Brief Operating Instructions
Proline 300
HART
Transmitter with Coriolis sensor
These instructions are Brief Operating Instructions; they are
These instructions are Brief Operating Instructions; they are
not a substitute for the Operating Instructions pertaining to
not a substitute for the Operating Instructions pertaining to
the device.
the device.
Transmitter Brief Operating Instructions
Transmitter Brief Operating Instructions
Contain information about the transmitter.
Contain information about the transmitter.
Sensor Brief Operating Instructions →  3
Sensor Brief Operating Instructions →  3
MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline 300 HART and is the answer not in the manual?

Questions and answers

Summary of Contents for TechnipFMC Proline 300 HART

  • Page 1 MANUAL Brief Operating Instructions Proline 300 HART Proline 300 HART Transmitter with Coriolis Sensor Transmitter with Coriolis sensor Brief Operating Instructions Manual Brief Operating Instructions Proline 300 KA01364O/06/EN/02.19 71454942 HART Transmitter with Coriolis sensor These instructions are Brief Operating Instructions; they are These instructions are Brief Operating Instructions;...
  • Page 2 Proline 300 HART Order code: XXXXX-XXXXXX Ser. no.: XXXXXXXXXXXX Ext. ord. cd.: XXX.XXXX.XX Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555...
  • Page 3 Proline 300 HART Brief Operating Instructions for the device Brief Operating Instructions for the device The device consists of a transmitter and a sensor. The process of commissioning these two components is described in two separate manuals: • Sensor Brief Operating Instructions •...
  • Page 4: Table Of Contents

    Table of contents Proline 300 HART Table of contents Document information ............5 Symbols used .
  • Page 5: Document Information

    Proline 300 HART Document information Document information Symbols used 1.1.1 Safety symbols Symbol Meaning DANGER! DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in WARNING serious or fatal injury.
  • Page 6 Document information Proline 300 HART Symbol Meaning Protective Earth (PE) A terminal which must be connected to ground prior to establishing any other connections. The ground terminals are situated inside and outside the device: • Inner ground terminal: Connects the protectiv earth to the mains supply.
  • Page 7: Basic Safety Instructions

    Proline 300 HART Basic safety instructions Basic safety instructions Requirements for the personnel The personnel must fulfill the following requirements for its tasks: ‣ Trained, qualified specialists must have a relevant qualification for this specific function and task. ‣ Are authorized by the plant owner/operator.
  • Page 8: Workplace Safety

    Basic safety instructions Proline 300 HART NOTICE Verification for borderline cases: ‣ For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability as minute changes in the temperature, concentration or level of contamination in the process can alter the corrosion resistance properties.
  • Page 9: Product Safety

    Proline 300 HART Basic safety instructions Product safety This measuring device is designed in accordance with good engineering practice to meet state- of-the-art safety requirements, has been tested, and left the factory in a condition in which it is safe to operate.
  • Page 10: Product Description

    Product description Proline 300 HART Product description The device consists of a Proline 300 transmitter and a Proline Promass or Cubemass Coriolis sensor. The device is available as a compact version: The transmitter and sensor form a mechanical unit. N ic...
  • Page 11: Installation

    Proline 300 HART Installation Installation For detailed information about mounting the sensor, see the Sensor Brief Operating Instructions →  3 Turning the transmitter housing To provide easier access to the connection compartment or display module, the transmitter housing can be turned.
  • Page 12: Turning The Display Module

    Installation Proline 300 HART Turning the display module The display module can be turned to optimize display readability and operability. – – – 3 mm A0030035 Depending on the device version: Loosen the securing clamp of the connection compartment cover.
  • Page 13: Cover Locking

    Proline 300 HART Installation Cover locking NOTICE Order code for "Housing", option L "Cast, stainless": The covers of the transmitter housing are provided with a borehole to lock the cover. The cover can be locked using screws and a chain or cable provided by the customer.
  • Page 14: Electrical Connection

    Electrical connection Proline 300 HART Electrical connection NOTICE The measuring device does not have an internal circuit breaker. ‣ For this reason, assign the measuring device a switch or power-circuit breaker so that the power supply line can be easily disconnected from the mains.
  • Page 15 Proline 300 HART Electrical connection Signal cable Current output 4 to 20 mA HART A shielded cable is recommended. Observe grounding concept of the plant. Current output 0/4 to 20 mA Standard installation cable is sufficient. Pulse/frequency/switch output Standard installation cable is sufficient.
  • Page 16 Electrical connection Proline 300 HART Standard cable - customer-specific cable No cable is supplied, and it must be provided by the customer (up to max. 300 m (1 000 ft)) for the following order option: Order code for DKX001: Order code 040 for "Cable", option 1 "None, provided by customer, max 300 m"...
  • Page 17: Connecting The Measuring Device

    Proline 300 HART Electrical connection 5.1.3 Terminal assignment Transmitter: supply voltage, input/outputs Supply voltage Input/output 1 Input/output 2 Input/output 3 1 (+) 2 (–) 26 (+) 27 (–) 24 (+) 25 (–) 22 (+) 23 (–) Device-specific terminal assignment: adhesive label in terminal cover.
  • Page 18 Electrical connection Proline 300 HART 5.2.1 Connecting the transmitter A0026781 Terminal connection for supply voltage Terminal connection for signal transmission, input/output Terminal connection for signal transmission, input/output or terminal connection for network connection via service interface (CDI-RJ45); optional: connection for external WLAN antenna or...
  • Page 19 Proline 300 HART Electrical connection N ic N ic t e r t e r e r g ö f f e r g ö f f iz e iz e t e n t e n r ir r ir...
  • Page 20 Electrical connection Proline 300 HART 22 mm 24 mm – A0029816 10. Connect the cable in accordance with the terminal assignment .  Signal cable terminal assignment: The device-specific terminal assignment is documented on an adhesive label in the terminal cover.
  • Page 21 Proline 300 HART Electrical connection Removing a cable 3 (0.12) A0029598  1 Engineering unit mm (in) To remove a cable from the terminal, use a flat-blade screwdriver to push the slot between the two terminal holes while simultaneously pulling the cable end out of the terminal.
  • Page 22: Ensuring Potential Equalization

    Electrical connection Proline 300 HART 5.2.2 Connecting the remote display and operating module DKX001 The remote display and operating module DKX001 is available as an optional extra . • The remote display and operating module DKX001 is only available for the following housing version: order code for "Housing": option A "Aluminum, coated"...
  • Page 23: Ensuring The Degree Of Protection

    Proline 300 HART Electrical connection Ensuring the degree of protection The measuring device fulfills all the requirements for the IP66/67 degree of protection, Type 4X enclosure. To guarantee IP66/67 degree of protection, Type 4X enclosure, carry out the following steps after the electrical connection: Check that the housing seals are clean and fitted correctly.
  • Page 24: Operation Options

    Operation options Proline 300 HART Operation options Overview of operation options A0034513 Local operation via display module Computer with Web browser (e.g. Internet Explorer) or with operating tool (e.g. FieldCare, DeviceCare, AMS Device Manager, SIMATIC PDM) Field Xpert SFX350 or SFX370...
  • Page 25: Structure And Function Of The Operating Menu

    Proline 300 HART Operation options Structure and function of the operating menu 6.2.1 Structure of the operating menu Operating menu for operators and maintenances Language Operation task-oriented Setup Diagnostics Operating menu for experts Expert function-oriented A0014058-EN  2 Schematic structure of the operating menu 6.2.2...
  • Page 26: Access To The Operating Menu Via The Local Display

    Operation options Proline 300 HART Access to the operating menu via the local display X X X X X X 19.184 mA 12.5 X X X X X X Language 20.50 Ã English Deutsch Español Français Xxxxxxx A B C D E F G H I J K M N O P Q R S T U V W +0.000 Xx...
  • Page 27 Proline 300 HART Operation options 6.3.1 Operational display Explanatory symbols for the measured value Status area • Depends on the device version, e.g.: The following symbols appear in the status area of the • : Volume flow operational display at the top right: •...
  • Page 28 Operation options Proline 300 HART Numeric editor Confirms selection. Moves the input position one position to the left. Exits the input without applying the changes. Inserts decimal separator at the input position. Inserts minus sign at the input position. Clears all entered characters.
  • Page 29: Access To The Operating Menu Via The Operating Tool

    Proline 300 HART System integration Keys and meaning Reduces the contrast (brighter setting). Plus/Enter key combination (press and hold down the keys simultaneously) Increases the contrast (darker setting). Minus/Plus/Enter key combination (press the keys simultaneously) For operational display:Enables or disables the keypad lock.
  • Page 30: Setting The Operating Language

    Commissioning Proline 300 HART • "Post-installation check" checklist →  13 • "Post-connection check" checklist →  23 Setting the operating language Factory setting: English or ordered local language X X X X X X X 20.50 Main menu 0104-1...
  • Page 31: Protecting Settings From Unauthorized Access

    Proline 300 HART Commissioning Example: Available submenus, wizards Meaning System units Configure the units for all measured values Medium selection Define the medium I/O configuration User configurable I/O module Current input Configuration of the input/output type Status input Current output 1 to n...
  • Page 32: Diagnostic Information

    Diagnostic information Proline 300 HART Diagnostic information Faults detected by the self-monitoring system of the measuring device are displayed as a diagnostic message in alternation with the operational display. The message about remedial measures can be called up from the diagnostic message, and contains important information on the fault.
  • Page 34 All information and technical specifications in this documentation have been carefully checked and compiled by the author. However, we cannot completely exclude the possibility of errors. TechnipFMC is always grateful to be informed of any errors. Contact us on the website.