  • Page 1 SD50 Pro LED Status Display Product Manual Original Instructions p/n: 242994 Rev. A 21-Nov-24 © Banner Engineering Corp. All rights reserved.
  • Page 2: Table Of Contents

    Contents Chapter 1 Features Models ........................................... 3 Chapter 2 Wiring........................4 Chapter 3 Pro Editor Configuration for the SD50 Pro LED Status Display Discrete Control......................................5 Basic I/O State ......................................6 Advanced I/O State....................................6 I/O Block I/O State ....................................7 Sequence Mode ......................................
  • Page 3: Models

    Models..........................................3 Chapter 1 Features The SD50 Pro Programmable LED Status Display provides diagnostics and indication for control engineers and OEMs who need to improve the interaction between operators and equipment to drive response speed and productivity improvements. • Bright programmable alphanumeric LED display •...
  • Page 4: Chapter 2 Wiring

      SD50 Pro LED Status Display Product Manual Chapter Contents Chapter 2 Wiring SD50 Pro Wiring 5-Pin Male M12 Pinout Pinout Key and Wiring Brown - Input 1 White - Input 3 Blue - DC Common Black - Input 2...
  • Page 5: Discrete Control

    Pro Editor Configuration for the SD50 Pro LED Status Display Banner's Pro Editor software offers an easy way to configure Pro Series-enabled indication, touch, and illumination devices, allowing users full control of device states and device logic modes. The easy-to-use configuration software provides a variety  of tools and capabilities to solve a wide range of applications such as indicating machine status or warm-up time, indicating unique steps in an assembly process, or incorporating status information into touch buttons. ...
  • Page 6: Basic I/O State

    SD50 Pro LED Status Display Product Manual Pro Editor Configuration for the SD50 Pro LED Status Display Basic I/O State Basic four-state control. Configurations made in Basic I/O State assign one wire to one state, with the following override control: •...
  • Page 7: I/O Block I/O State

    I/O blocks, for which power (brown) and common (blue) are always on for five-pin connections. Sequence Mode Sequence Mode allows up to sixteen states that a single input can control. A pulse on the input wire moves the SD50 Pro to the next state. Reset State Input Choose the desired input wire to restart the SD50 Pro to the First Animation as chosen in the dropdown menu.
  • Page 8: Timer Mode

    Set a total time and up to four thresholds. Start and stop the timer counting up or down with discrete control. Colors change across threshold values. Timer Mode uses the SD50 Pro as a timer, counting up or down. Count Seconds The total time of the timer.
  • Page 9: Measure Mode

    Text that displays after the Count Value to indicate the units displayed. This can be up to three characters. Standard Settings Reset the SD50 Pro to predetermined settings. Measure Mode Measure Mode uses the SD50 Pro to display a measurement as either PWM control or PFM control. PWM: Pulse-Width Modulation. PWM/PFM PFM: Pulse-Frequency Modulation.
  • Page 10: Factory Reset

    SD50 Pro LED Status Display Product Manual Pro Editor Configuration for the SD50 Pro LED Status Display Continued from page 9 Hysteresis Level The level of lag between the measurement thresholds to minimize the flickering at switch points. Output Scale Value Low The low-end value of the output translated from the input frequency.
  • Page 11: Chapter 4 Specifications

      SD50 Pro LED Status Display Product Manual Chapter Contents FCC Part 15 Class A for Unintentional Radiators............................... 12 Industry Canada ICES-003(A).................................... 12 Dimensions......................................... 12 Chapter 4 Specifications Supply Voltage Animations 12 V DC to 30 V DC Use only with a suitable Class 2 power supply (UL) or SELV...
  • Page 12: Fcc Part 15 Class A For Unintentional Radiators

    SD50 Pro LED Status Display Product Manual Specifications FCC Part 15 Class A for Unintentional Radiators This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 13: Chapter 5 Accessories

      SD50 Pro LED Status Display Product Manual Chapter Contents Cordsets ..........................................13 Mounting Brackets......................................13 Chapter 5 Accessories Cordsets 5-Pin Double-Ended M12 Female to M12 Male Cordsets Model  Length  Style  Dimensions  Pinout (Male)  Pinout (Female)    MQDEC-501SS  0.31 m (1.02 ft)  40 Typ.  ...
  • Page 14 SD50 Pro LED Status Display Product Manual Accessories LMBSD50-180SMAG • Magnetic mounting bracket kit with 180-degree rotation • Stainless steel • Up to 7.26 kg (16 lb) pull Ø52 • Hardware included     page 14 of 21 21-Nov-24 © Banner Engineering Corp. All rights reserved.
  • Page 15: Chapter 6 Product Support And Maintenance

      SD50 Pro LED Status Display Product Manual Chapter Contents UTF-8 Encoding Table and Unicode Characters..............................15 Clean with Mild Detergent and Water................................. 19 Repairs ..........................................19 Contact Us.......................................... 20 Banner Engineering Corp Limited Warranty............................... 20 Chapter 6 Product Support and Maintenance UTF-8 Encoding Table and Unicode Characters...
  • Page 16 SD50 Pro LED Status Display Product Manual Product Support and Maintenance Continued from page 15 Unicode Code Point Character UTF-8 (hex.) Name U+003F QUESTION MARK U+0040 COMMERCIAL AT U+0041 LATIN CAPITAL LETTER A U+0042 LATIN CAPITAL LETTER B U+0043 LATIN CAPITAL LETTER C...
  • Page 17 Product Support and Maintenance SD50 Pro LED Status Display Product Manual Continued from page 16 Unicode Code Point Character UTF-8 (hex.) Name U+0069 LATIN SMALL LETTER I U+006A LATIN SMALL LETTER J U+006B LATIN SMALL LETTER K U+006C LATIN SMALL LETTER L...
  • Page 18 SD50 Pro LED Status Display Product Manual Product Support and Maintenance Continued from page 17 Unicode Code Point Character UTF-8 (hex.) Name U+00B4 ´ c2 b4 ACUTE ACCENT U+00B5 µ c2 b5 MICRO SIGN U+00B6 ¶ c2 b6 PILCROW SIGN U+00B7 ·...
  • Page 19: Clean With Mild Detergent And Water

    Repairs Contact Banner Engineering for troubleshooting of this device. Do not attempt any repairs to this Banner device; it contains no field-replaceable parts or components. If the device, device part, or device component is determined to be defective by a Banner Applications Engineer, they will advise you of Banner's RMA (Return Merchandise Authorization) procedure.
  • Page 20: Contact Us

    Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.