2.2 Wiring Diagrams ................................5 2.3 Connection Options ................................5 2.3.1 Connecting the RSD1 to a Sensor ......................... 6 2.3.2 Connecting the RSD1 to a Control System ......................6 3 Programming a Sensor with the RSD1 ........................7 3.1 RSD1 Menu (MENU) ................................7 3.2 Sensor Configuration Menu (CONFIG)
Figure 2. RSD1 Display in Run Mode 1.3.2 RSD1 Buttons Use the RSD1 buttons Down, Up, Enter, and Escape to view or change RSD1 settings and information and to program a connected sensor. www.bannerengineering.com - Tel: +1.763.544.3164...
Page 4
In the RSD1 Menu, a return arrow in the upper left corner of the display indicates that pressing Escape returns to the parent menu. Press and hold Escape for 2 seconds to return to Run mode from the RSD1 Menu. www.bannerengineering.com - Tel: +1.763.544.3164...
2.3 Connection Options When connecting the RSD1 to a sensor or control system, an adapter may be required depending on the sensor. For additional information on how to connect the RSD1, see the information below. Note: RSD1 pin-5 (gray wire) is used to communicate with an attached sensor.
2.3.2 Connecting the RSD1 to a Control System When connecting the RSD1 to a control system, there are many combinations of double-ended and flying leads that can be used to fit your application needs. See sensor specific literature for additional cordset options.
RSD1 Remote Display 3 Programming a Sensor with the RSD1 When connected to a sensor and in Run Mode, the RSD1 mirrors the connected sensor's display. Program a sensor using the buttons on the RSD1. For sensor programming information, reference the literature specific to the connected sensor.
If a sensor configuration has been imported, the user configuration data can be exported to a connected remote sensor. To export user configuration data, navigate to the Export menu using the RSD1 push buttons and press the Enter button. Navigate to Yes and press theEnter button.
Remote input settings are passed directly to the remote sensor. For sensor remote input programming information, reference the literature specific to the connected sensor. RSD1 Remote input is used to control the export function on the RSD1 and to load new configurations to Remote Input the attached sensor. For more information, see on page 13.
3.4.1 View The View option sets the display orientation of the RSD1. For applications where the display must be mounted so that it is not right-reading, invert the display for readability. The Down and Up buttons do not change when the display is inverted.
The RSD1 display can be locked to prevent unauthorized or accidental programming changes. 3.5.3 OpLock The RSD1 display can be locked while still allowing for the export of user configuration data using the OpLock feature. 3.6 Information Menu (INFO) www.bannerengineering.com - Tel: +1.763.544.3164...
Select one of these options to view specific information for the connected sensor. This information is read-only. Navigate: MENU > INFO 3.6.1 Diags Diagnostic display options are available for system diagnostics and may be requested by a Banner Engineering Applications Engineer. 3.7 Reset Menu (RESET) Use the Reset menu to restore the RSD1 to the factory default settings.
OpLock 3.10 Remote Input Use the remote input to program the RSD1 remotely. Activate remote input using the RSD1 buttons to navigate to the RSD1 Input Type menu option. For Active Low, connect the gray input wire to ground (0 V dc), with a remote switch connected between the wire and ground.
RSD1 Remote Display 4 Specifications Supply Voltage Connection Use only with suitable Class 2 power supply Integral 150 mm (6 in) PVC cable with 5-pin M12/Euro-style quick disconnect 12 V dc to 30 V dc: • Max. load of 330 Ω for analog current (4 mA to 20 mA)
Switch RSD Disp View Normal Invert Sleep Disable 1 min 5 min 15 min 60 min RSD Lock Unlock Lock Oplock RSD Info Model Version Diags Diag1 Diag2 Diag3 Reset Figure 12. RSD1 Full Menu Map www.bannerengineering.com - Tel: +1.763.544.3164...
Hole size: 25.4 x 5.3 All measurements are listed in millimeters, unless noted otherwise. 6.2 Cordsets The following cordsets can be used to extend the distance between the sensor and RSD1. 5-Pin Male Threaded and 5-Pin Female Quick Disconnect M12/Euro-Style Cordset—Double Ended Model Length "L1"...
Page 17
40 ± 0.5 “L1” The following cordsets can be used to connect the RSD1 to a control system using the white wire (pin-2) as remote input for Remote TEACH, Laser Off, Laser On. 4-Pin Male and 5-Pin Female Threaded M12/Euro-Style Cordsets—Double Ended Model Length "L1"...
RSD1 Remote Display 7 Troubleshooting 7.1 Errors Error Message Description Solution NoSensor Found... No sensor connected Connect a sensor Fail NoSensor No sensor connected Connect a sensor Fail NotMatch Sensor version mismatch–the sensor Use a different sensor or select a different export...
9 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.