OMC valves are not designed to cope with external stresses that can be induced by the systems in which they are inserted. It is the installer's responsibility to take these efforts into account and to take appropriate precau ons.
Periodically check for any internal and/or external corrosion and/or erosion phenomena as they can cause significant damage to the parts under pressure, locally reducing their thickness and consequently their degree of safety. Page 4 OMC S.p.A. Via Mestre—Cernusco sul Naviglio (MI) - ITALY - www.omcvalves.com - Tel.: (+39) 02.95.28.468...
2.0 INSTALLATION All work must be carried out and supervised by experienced, trained and competent staff. The OMC valves' body casting highlights the flow direction, the nominal passage, the maximum operating pressure and the material. Before installing the valve, make sure that the pipe that conveys the process fluid is clean, proceeding, if possible, to an energetic blowing with steam or compressed air.
All the operations described below must be carried out and supervised by expert, trained and competent staff. OMC valves are uniquely identified by a serial number shown on the plate located on the actuator yoke. To order spare parts or for any need, always refer to the aforementioned number.
2.01, applying the torques indicated in chapter 5 Warning: when replacing the rod (2) it is also necessary to replace the packing gland (see next paragraphs). Pic. 7 diverter valve Page 8 OMC S.p.A. Via Mestre—Cernusco sul Naviglio (MI) - ITALY - www.omcvalves.com - Tel.: (+39) 02.95.28.468...
2.01, applying the torques indicated in chapter 5 Warning: when replacing the plug it is also necessary to replace the packing gland (see next paragraphs). Pic. 8 Mixer valve OMC S.p.A. Via Mestre—Cernusco sul Naviglio (MI) - ITALY - www.omcvalves.com - Tel.: (+39) 02.95.28.468 Page 9...
2.01, applying the torques indicated in chapter 5 Warning: it is always advisable to also replace the packing gland (see next paragraphs Pic. 9 Diverter valve with bellows Page 10 OMC S.p.A. Via Mestre—Cernusco sul Naviglio (MI) - ITALY - www.omcvalves.com - Tel.: (+39) 02.95.28.468...
2.01, applying the torques indicated in chapter 5 Warning: it is always advisable to also replace the packing gland (see next paragraphs Pic. 10 Mixer valve with bellows OMC S.p.A. Via Mestre—Cernusco sul Naviglio (MI) - ITALY - www.omcvalves.com - Tel.: (+39) 02.95.28.468 Page 11...
Page 12
Warning: always replace the packing gland (10) (see next paragraphs) and the gaskets (29), (7), (16), (24), (27) and (28). Pic. 11 DN250/10” valve OMC S.p.A. Via Mestre—Cernusco sul Naviglio (MI) - ITALY - www.omcvalves.com - Tel.: (+39) 02.95.28.468 Page 12...
EcoPack 2 stem packing gland WARNING!!! OMC valves are uniquely identified by a serial number shown on the plate located on the actuator yoke. To order spare parts or for any other need, always refer to the aforementioned number. 9.0 PRESSURE/TEMPERATURE RELATIONSHIP...
1/2” ÷ 1” DN32÷ DN250 Group 1 B + C2 1”1/2 ÷ 10” 11.0 PLATES 11.01 IDENTIFICATION PLATE All OMC valves are provided with an identification plate to make the identification of the valve univocal. NUMBER TEXT DESCRIPTION Mod. Valve model Body...
Need help?