Page 3
Personal Daq Quick Start Personal Daq/54, /55, /56 For: PDQ1 and PDQ2 When using Personal Daq modules to acquire data, computer energy save modes can cause false data readings. Prior to using Personal Daq modules, ensure your computer’s energy save mode is disabled.
Page 4
Installing Personal DaqViewXL Personal DaqViewXL is an Excel-based application that is available as a purchased-option. To install a non-trial version of the application you will need an authorization code. The code is provided at the time of purchase. To install the application: 1.
An expansion module (PDQ1 or PDQ2) can be added to Personal Daq/55 and /56 units. Although an expansion module can physically connect to a Personal Daq/54, it will not function with the unit. Personal Daq/54 does not include expansion functionality. For Personal Daq/54 the 25-pin port is used only for calibration.
Page 6
Use Personal Daq’s screw terminals to connect channel inputs to your Personal Daq system. Note that the terminal blocks are detachable for ease in making connections. Personal Daq/54, /55, and /56 and PDQ expansion modules PDQ1 and PDQ2 have labels which clearly identify each input type and channel number.
Page 7
Connecting Thermocouple Wires In Personal Daq applications, thermocouples should not be connected single-ended. Doing so can result in noise and false readings. This is especially true when acquiring other high- amplitude signals in conjunction with thermocouple signals that are connected single- ended.
(4) Configure the System This step pertains to the configuration of channels and acquisition parameters through Personal DaqView software. To configure a set of parameters, use the appropriate toolbar button (or the View pull-down menu) to open the applicable window. Clicking on the Configure Channel Settings button (9) brings up the Channel Configuration Window.
Page 9
User Label, On, Type, Units, Edge, Debounce, Min. Value, Max. Value, Resolution Frequency/Pulse Input (Settling Time), Scale, Offset. Frequency/Pulse Input does not apply to Personal Daq/54. User Label, On, Input/Output, Output State, Power-Up State. Digital Input/Output Digital I/O does not apply to Personal Daq/54.
The Configure Acquisition Window has the following default settings. Pre-Trigger: No duration set, i.e., a duration of 0 scans Trigger: Immediate Post Trigger: Manual stop Averaging: None Acquisition Parameters: Set for Maximum scan rate Frequency: selected Period: not-selected Continuous Calibration: not-selected Overrange Protection: selected You can change the acquisition setup as desired.
Page 11
2. Select the tab for the desired spreadsheet. Analog Input is the default. Note that the Frequency/Pulse Input and Digital Input/Output tabs do not apply to Personal Daq/54. 3. Ensure the desired channels are enabled. Double-click in a channel’s On/Off cell to enable or disable a channel, as applicable.
• A copy of troubleshooting notes and comments on tests performed and all problem-related conditions. IOtech, Inc. 25971 Cannon Road Cleveland, OH 44146-1833 Phone: (440) 439-4091 Fax: (440) 439-4093 e-mail (Product Information): sales@iotech.com e-mail (Technical Support): productsupport@iotech.com Internet: http://www.iotech.com 491-0940, Personal Daq Quick Start 878495...
Need help?
Do you have a question about the Personal Daq/54 and is the answer not in the manual?
Questions and answers