LB 1800/2800/4000 Modular
Installation and Operating Manual
Spectra Watermakers
Katadyn Desalination LLC.
2220 S. McDowell Blvd. Petaluma, CA 94954
Phone: 415-526-2780 Fax: 415-526-2787
www.spectrawatermakers.com
Updated March 2025

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LB 1800 Modular and is the answer not in the manual?

Questions and answers

Summary of Contents for Spectra Watermakers LB 1800 Modular

  • Page 1 LB 1800/2800/4000 Modular Installation and Operating Manual Spectra Watermakers Katadyn Desalination LLC. 2220 S. McDowell Blvd. Petaluma, CA 94954 Phone: 415-526-2780 Fax: 415-526-2787 www.spectrawatermakers.com Updated March 2025...
  • Page 3: Table Of Contents

    Table of Contents Installation Instructions Introduction....................4 Valve and Gauge Panel Connections.............5 Component Description.................7 Fitting Assembly Procedures.................10 Plumbing Schematic..................12 Plumbing Connections..................14 Electrical Connections - DC................17 Electrical Connections - AC................19 Operation Valve and Control Panel Layout..............22 Initial Start-up (Purging Storage Solution)............23 Normal Operation..................24 Fresh Water Flushing - DC................25 Fresh Water Flushing - AC................26 Care and Maintenance...
  • Page 4: Introduction

    Introduction Welcome to Spectra Watermakers, your trusted solution for water purification needs. Introducing the Spectra LB-1800/2800/4000, equipped with the revolutionary Spectra Pearson Pump. This cutting-edge high-pressure pump, featuring integrated energy recovery, empowers users to purify up to 75 gallons of seawater per hour (120 gph for the LB-2800) on as little as 750 watts of power.
  • Page 5: Valve And Gauge Panel Connections

    Valve and Gauge Panel Connections Limit Switches The Normally Closed terminals on the membrane pressure switch are connected to the controls and will stop the system if it exceeds 850 psi. The Feed Pressure limit switch is also wired to the Normally Open terminals and will close when the feed pressure exceeds 10psi.
  • Page 6 Valve and Gauge Panel Connections - Back of Panel Filter Condition — Inlet Filter Condition — Outlet Boost Pressure Vacuum Switch Product Inlet Filter Condition Gauge Seawater Inlet Fresh Water Flush Inlet Feed Water Outlet High Pressure Limit Switch Product Water Outlet Membrane Pressure Connection...
  • Page 7: Component Description

    Component Descriptions The Spectra LB-1800/2800/4000 watermaker is designed to be installed in a building or pump house so the system is not exposed to the elements. Feed water must be supplied to the unit at 6gpm (22 lpm) at a minimum of 10psi (0.7bar) and a maximum of 20psi (3.5 Bar). A media filter, which must be sourced independently by the consumer, can be used to reduce the consumption of the cartridge filters.
  • Page 8 Component Descriptions - Cont. The Valve and Gauge Panel has the analog gauges and valves mounted used to monitor and operate the system. There is a flow meter for the feed and one for the product water. One three-way valve controls the feed water source to switch between running and flush water.
  • Page 9 Component Descriptions - Cont. The Valve and Gauge Panel has a series of analog gauges and valves mounted for easy reference to system operation. There are two flow meters, one to measure the inlet flow from the feed pump and the other to measure the product water flow rate.
  • Page 10: Fitting Assembly Procedures

    Parker Tube Fitting Assembly Procedure...
  • Page 11 John Guest Super Speedfit Fittings...
  • Page 12: Plumbing Schematic

    LB 1800-4000M Plumbing Schematic Note: The inlet and discharge service valves should be installed so the service hoses (when installed) can both be place inside the same bucket. To clean or pickle the system chemicals will be recirculated through the system and must be done with no air in the circulation loop.
  • Page 13 LB 1800-4000M Plumbing Schematic Cont.
  • Page 14: Plumbing Connections

    Plumbing Connections To Filter Condition To Filter Condition Outlet Gauge Inlet Gauge Purge Inlet Service Valve Buttons Feed Water Inlet Service Inlet (for pickling or cleaning) Filter Filter Inlet Outlet Brine Discharge Service Return (for pickling or Brine cleaning) Install the 3/4” 3-way Inlet service valve in front of the Prefilter and connect the Filter Outlet to the Feed Water Inlet on back of the control panel (see opposite).
  • Page 15 Plumbing Connections Cont. Brine Service Valve Restrictor –Assembled at Factory The system is more tolerant to changed in feed pressure and knocking is reduced if there is a restrictor in the brine discharge line. This restriction creates 3-5 psi of back pressure in the discharge which will increase that range of acceptable feed pressure.
  • Page 16 Plumbing Connections - Cont. Product Water Outlet Connect the 1/2” black tubing to the product water outlet fitting on the membrane end cap. Lead the 1/2” hose to the bottom fitting of the product flow meter on the Control Panel. Connect the product flow meter outlet fitting at the top of the flow meter to the common port (bottom of the T) of the supplied 3-way sampling valve, one port should be plumbed to a sampling tap, and the other should be plumbed to the potable water storage tank.
  • Page 17: Electrical Connections - Dc

    Electrical Connections Systems Pressure Switch cable Mount the Electrical Control Box within 6 feet (2meters) of the motor for the Spectra Pearson Pump. Mount vertically and in a dry location, preferably above the pump assembly to ensure proper ventilation across the heat-sink and so that no water will accidentally spill on the switches or speed control knob.
  • Page 18: Systems Only

    Electrical Connections Systems Only Connect the main DC Power leads from the DC Bus to the 2 position buss bar located above the speed controller. Connect the DC + to the Red Conductor and DC - to the Yellow conductor. The ‘External Run Signal’...
  • Page 19: Electrical Connections - Ac

    Electrical Connections Systems Only • Mount the control box so the attached gray pressure switch cables will reach the switches the back of the control panel. • Insure the power switch on the front of the control box is in the off position. •...
  • Page 20 Electrical Connections Systems Only 3 Phase Pearson Pump motor connections 220VAC power input Pressure Switch cables connect to the N/O (Normally Open) terminals on the pressure switches. There are either two Spade connectors or a single multi pin connector on the end of this cable (depending on which pressure switch was used).
  • Page 21 Electrical Connections Systems Only - Cont. Before powering up your AC LB Modular system, be sure to (AC Control Box) connect the Pressure Switch Cables from the AC Control Box to the High and Low Pressure Switches on the back of the Plumbing Panel.
  • Page 22: Valve And Control Panel Layout

    Valve and Gauge Control Panel Feed Water Source Selector Valve (run or Prefilter Condition Selector Valve flush) Inlet of filter or outlet of filter Product Flow Meter Shown in OFF position Shown measuring Inlet Feed Flow Meter Membrane Pressure Prefilter Condition Gauge Check the filter condition daily and change filter(s) if the difference between IN and OUT is more that 5 psi Prefilter Bleed Button...
  • Page 23: Initial Startup (Purging Storage Solution)

    Initial Startup (Purging Storage Solution) Note: The crankcase in this unit shipped from the factory with oil in the crankcase and tape over the crankcase vent. Confirm that the crankcase is roughly half-full of oil before starting the watermaker (there is a sight glass on back of the crankcase). When starting the machine for the first time ensure the product water is going to a drain until it becomes potable.
  • Page 24: Normal Operation

    Normal Operation Note If the system contains preservative or antifreeze, or if the condition of the membrane is unknown, follow the “Initial Startup” (purging) instructions on the previous page. When in doubt, Purge the system before running at pressure. Starting: Set the product sampling valve (if used) to send the product to a drain. Turn the feed valve to the ‘RUN’...
  • Page 25: Fresh Water Flushing - Dc

    Fresh Water Flushing - System It is always a good idea to flush the watermaker after each production cycle. If the system is not used to make water the flush process should be repeated once every 3-5 days, depending on climate (shorter cycle in warm climates) to prevent bacteria growth. Turn off the feed water supply pump and close the Feed valve (OFF).
  • Page 26: Fresh Water Flushing - Ac

    Fresh Water Flushing - System It is always a good idea to flush the watermaker after each production cycle. If the system is not used to make water the flush process should be repeated once every 3-5 days, depending on climate (shorter cycle in warm climates) to prevent bacteria growth. Turn off the feed water supply pump and close the Feed valve (OFF).
  • Page 27: Maintenance

    Maintenance General In installations where the unit is running 24/7 it is prudent to perform a weekly visual inspection. Pressures and flow rates should be recorded in the log for reference. Repair any leaks as soon as possible. Periodically inspect the entire system for leaks and any chafing on the tubing and hoses.
  • Page 28 Maintenance - Cont. GEARCASE LUBE OIL Use only 5W-30 synthetic oil in Spectra-Pearson Pump crankcase. Do not overfill the crankcase with oil. Check oil condition and level frequently. The oil should be changed every 5000 hours or annually, whichever comes first. The Pearson Pump comes mounted on a counterclockwise rotating CAT crankcase.
  • Page 29: Long Term Storage

    If there is danger of freezing Propylene Glycol potable water antifreeze should be used instead of Spectra Watermakers SC-1. The Pressure Relief Knob on the Spectra Pearson Pump must be open one full turn while circulating preservatives or cleaning compounds! Spectra SC-1 is a special storage compound used by the US Navy.
  • Page 30: Long Term Storage Connection Guide

    Long Term Storage Connection Guide Connect the 3/4” Suction Hose in the Service kit to the Service Inlet on the 3-Way Ball Valve. Turn the arrow on the yellow handle so that the arrow now points toward the Service Inlet. Inlet Service Valve Place one end of the suction hose Service Inlet...
  • Page 31: Storing With Antifreeze

    Storing with Antifreeze (Winterizing) Antifreeze System Flushing Instruction Preparation: • Ensure the system has been thoroughly flushed with fresh water. • You will need approximately 5 US gallons (20 liters) of propylene glycol potable water antifreeze*. Initial Setup: • Open the pressure relief knob. •...
  • Page 32: Membranes/Membrane Cleaning

    The acid cleaner should be used first. If the membrane fails to respond to both cleanings, this is an indication of another problem with the system, or that it is time to replace the membrane. Contact Spectra Watermakers before removing a membrane. Membrane Cleaning Warning! The pressure relief valve on the Spectra Pearson Pump must be open for this procedure or membrane damage may result.
  • Page 33: Cleaning Procedure

    You will need 5 gal (20 L) of chlorine free water and the system must have already been thoroughly flushed. 1 lb. (.5 kg) of Spectra Watermakers cleaning chemical into the water and stir It will dissolve in about an hour. Some of the chemical may not dissolve completely, this is normal.
  • Page 34: Troubleshooting

    Spectra Watermakers Troubleshooting Procedures Symptom Probable Cause Remedy Spectra-Pearson Pump Air in system - check feed water delivery knocks and bangs loudly Boost Pressure too high system and pressure or too low - adjust feed pressure System will not stay running...
  • Page 35: Specifications

    Specifications Power consumption will vary with changes in feed water flow rate, salinity and temperature. On standard seawater the 1800 will draw ≈800 watts and the 2800 will draw ≈1200 watts. The boost pump for the feed will typically draw 150 to 300 watts depending on the lift and distance required for pipe runs.
  • Page 36: Ac Wiring Diagram

    AC Wiring (220V) - LB 1800/2800/4000...
  • Page 37 AC Wiring (220V) - LB 1800/2800/4000...
  • Page 41: Parts

    LB Modular System - Parts I.D. Note: Systems shown in photos may be 1800, 2800, or 4000 Modular systems. Pay attention to number of Pressure Vessels/Membranes if you need to determine what system you are viewing. 3-PC BIG BLUE FILTER HOUS.
  • Page 42 LB Modular System - Parts I.D. FM-LB-1800CP LB-1800 CONTROL PANEL BRACKET (MAN) PL-PSG-2.5HP1K PL-PSG-2.5LP60 2.5"1000 PSI/BAR 1/4 B 0-60 PSI PRESSURE UC SPECTR CM GAUGE 2.5",1/4"NC PL-FMT-10GPM PL-FMT-5GPMDS 0-10 GPM FLOWMETER 5 GPM DUAL SCALE 8-3/8"HEIGHT SIDE FLOWMETER PORTS...
  • Page 43 LB Modular System - Parts I.D. PL-VLV-3W1/2 1/2" THREE WAY VALVE EL-SWT-LP LOW PRESSURE SWITCH PL-HS-3/4VN 3/4" VINYL HOSE PL-VLV-3W1/4 1/4" THREE WAY VALVE EL-SWT-HP HIGH PRESSURE SWITCH...
  • Page 44 LB Modular System - Parts I.D. PL-BSH-3/4X1/2N PL-CLP-3/4CAR (2X) PL-MFF-1/2X1/2 3/4" X 1/2" HEX 3/4" CARLON BUSHING 1/2" MPT X 1/2" FPT PL-TEE-3/4FN CLAMP REDUCER NYL ELBOW FITT. NYLON 3/4” FPT TEE NYLON PL-BSH-3/4X1/4N 3/4" X 1/4" HEX PL-MTE-1/4X1/4J (3X) BUSHING REDUCER NYL 1/4"NPT X 1/4"...
  • Page 45 LB Modular System - Parts I.D. 1/2" THREE WAY Brine Service Valve Restrictor VALVE PL-VLV-3W1/2 1/2"NPT X 3/4" HOSE BARB ELBOW PL-HBE-1/2X3/4 3/4"MGHT X 1/2"MALE NIPPLE PL-GHF-3/4X1/2 1/2"NPT X 3/8"NPT CLOSE NIPPLE PL-NP-1/2X3/8N 1/2" x 3/8" HEX BUSHING REDUCER NYL PL-BSH-1/2X3/8N 1/2"FPT X 3/4"...
  • Page 46 LB Modular System - Parts I.D.
  • Page 47 LB Modular System - Parts I.D. Manual Pressure Sensor 1/4"NPT X 1/4"TUBE FITT. ELL SS. PL-MTE-1/4X1/4S PP5M HP FITTING X 1/2"NPT ST 316S PP-5M-FT-1/2HPM 1/2" X 1/4" HEX BUSH- ING REDUCER SS. PL-BSH-1/2X1/4S 1/2" FPT TEE SS. PL-TEE-1/2FS 1/2"NPT X 1/2" MALE JIC PP5 DAMPER PORT -017 37 SS316 PL-MFS-1/2X1/2F...
  • Page 48 LB Modular System - Parts I.D. 2H.P. MOTOR 220 AC 3 PH, 1750 RPM EL-MTR-2HP220AC 4" PVC PIPE SCH 80 PL-TB-4PVCSCH80 (22.5” Long) SPECTRA PRESSURE VESSEL END RING 4” FT-PV-ER4IN 4” SPECTRA END CAP 2ND GEN FT-PV-EC4IN2NDG Not Pictured: Not Pictured: 4”...

Table of Contents