Seeley Breezair EXQ Series Owner's Manual
Seeley Breezair EXQ Series Owner's Manual

Seeley Breezair EXQ Series Owner's Manual

Evaporative coolers

Advertisement

Quick Links

This Owner's Manual is provided and hosted by Appliance Factory Parts.
Breezair EXQ170
Owner's Manual
Shop genuine replacement parts for Breezair EXQ170
Find Your Breezair Evaporative Cooler Parts - Select From 59 Models
-------- Manual continues below --------

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Breezair EXQ Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Seeley Breezair EXQ Series

  • Page 1 This Owner's Manual is provided and hosted by Appliance Factory Parts. Breezair EXQ170 Owner's Manual Shop genuine replacement parts for Breezair EXQ170 Find Your Breezair Evaporative Cooler Parts - Select From 59 Models -------- Manual continues below --------...
  • Page 2 OWNER’S MANUAL EXQ / EZQ / EXS Evaporative Coolers ILL1672-A (English) Original English Instructions...
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS FOR EUROPE READ AND SAVE THESE INSTRUCTIONS FOR This appliance can be used FUTURE REFERENCE. by children aged from 8 years and above and persons with WARNING - TO REDUCE THE reduced physical, sensory RISK OF FIRE, ELECTRIC or mental capabilities or SHOCK, OR INJURY TO lack of experience and...
  • Page 4: Important Notes

    Schedule is properly filled out components. (ie names, signature, date, and If the supply cord is damaged, action taken) when the item is it must be replaced by a Seeley completed. service agent or similarly ANY FAILURE TO CARRY qualified person in order to OUT THE REQUIRED avoid a hazard.
  • Page 5: Table Of Contents

    TABLE OF CONTENTS OPERATING YOUR COOLER MAGIQTOUCH CONTROLLER OPERATION MAGIQTOUCH CONTROLLER SETTINGS MENU ® About Appliance Min/Max Set Temperature Night Quiet Mode Manual Drain Pad Flush Drain and Dry AutoClean External Sensor MAGIQCOOL CONTROLLER SETTINGS Manual mode Auto mode MAGIQCOOL CONTROLLER OPERATION Turning the cooler on Preparing to start Manual mode...
  • Page 6: Operating Your Cooler

    Hello and congratulations on purchasing a Seeley evaporative MAGIQTOUCH CONTROLLER ® cooler SETTINGS MENU At Seeley International we manufacture Your MagIQtouch Controller contains a settings Breezair evaporative coolers from the highest menu which gives you access to information about ®...
  • Page 7: Magiqcool Controller Settings

    MAGIQCOOL CONTROLLER MAGIQCOOL CONTROLLER SETTINGS OPERATION MagIQcool Wall Controllers can operate in manual or automatic mode. Manual mode Manual mode will allow you to change settings for operating the cooler, such as altering fan speeds, pump control and manual drain control.
  • Page 8: Auto Mode

    MAGIQCOOL CONTROLLER MAGIQCOOL CONTROLLER OPERATION CONT OPERATION CONT Delayed Start or Stop You may then press the button to switch between COOL and VENT (where fresh The cooler can be programmed to start at a air is being delivered but not cooled). specific time or stop at a specific time.
  • Page 9: Programming In Auto Mode

    MAGIQCOOL CONTROLLER OPERATION CONT. Programming In Auto Mode Service Mode (1)..Press the button. When a fault has been recognised by the wall control the word “Service” flashes on the (2)..Press the button until AUTO is screen. displayed. (3)..Press the button and the Service "Starts in"...
  • Page 10: Drain Mode (Cooler Switched Off)

    MAGIQCOOL CONTROLLER OPERATION CONT. If ‘02’ is displayed (1)..Check that the water supply tap to the cooler is turned on. (2)..Check that your local water authority haven’t temporarily disconnected the water in your area. If ‘04’ is displayed (1)..If your cooler is fitted with a drain valve, check that the drain is not blocked.
  • Page 11: Water Management

    WATER MANAGEMENT Your evaporative cooler will be fitted with either open the drain valve and release saline water. a WaterMiser system, or a continuous bleed Fresh water will then be added diluting any ® system. Check with your dealer to determine minerals or salts accumulated.
  • Page 12: Maintenance

    If your or checks be carried out by an authorised cooler is fitted with a drain valve, no Seasonal Seeley International dealer or service agent. Maintenance is required. Climbing onto the roof can be hazardous...
  • Page 13: Removing Pad Frames

    REMOVING PAD FRAMES PAD FRAME POSITIONS To remove a pad frame: When re-fitting pads, ensure that they are fitted in their original positions. EXQ210, 1. Remove the clips holding the pad frame EZQ215 and all EXS model coolers have pads in place.
  • Page 14: Maintenance Schedule

    MAINTENANCE SCHEDULE Service Item Check/Adjust Clean Replace Water Distribution System Chillcel Pads (replace as required) Pad Retaining Washers/Pins Tank/Water Reservoir Pump Filter Water Probes System Washers, Seals and O’Rings (replace as required) Drain Valve/Bleed Funnel operation Component Function Pump operation Drain Valve operation Motor Operation Solenoid operation...
  • Page 15: Troubleshooting

    If your controller prompts you to call a service agent, please contact your local Seeley International authorised dealer or the service number on the back of this manual. Important! In an emergency we recommend that you immediately cease operating the appliance,...
  • Page 16: How To Register Your Product Warranty (Australia Only)

    HOW TO REGISTER YOUR PRODUCT WARRANTY (AUSTRALIA ONLY) Warranty Information section HOW TO REGISTER YOUR PRODUCT WARRANTY (Australia only) Please register your warranty online by visiting www.seeleyinternational.com and following these steps: Step 1 Select “GET SUPPORT” and “REGISTER A WARRANTY” Step 2 Select the brand of the product you purchased Step 3...
  • Page 17: Warranty Terms And Information (Australia Only)

    Warranty Details (Australia only) In this warranty: We or us means Seeley International Pty Ltd (Seeley) ABN 23 054 687 035, and our contact details are set out at the end of this warranty; You means you, the original end-user purchaser of the Goods;...
  • Page 18 Plug Connect models only parts are covered, not labour) but you will be responsible for: the cost of travel incurred for a Seeley International service agent to get to and from the location of the Goods if the location of the Goods is either: (i) outside the metropolitan areas of the capital cities; or (ii) more than 35 kilometres from an authorised Seeley International branch or service representative;...
  • Page 19 12. This warranty is only valid and enforceable in Australia. Note: Seeley and its service agents reserve the right to refuse service unless safety and accessibility to the unit can be guaranteed. If a service call reveals no warranty fault found with the Goods, a charge will be made for the call.
  • Page 21 6 WITTON ROAD, FOUNDERSVIEW SOUTH, MODDERFONTEIN 1609, GAUTENG, SOUTH AFRICA It is the policy of Seeley International to introduce continual product improvement. Accordingly, specifications are subject to change without notice. Please consult with your dealer to confirm the specifications of the model selected.

This manual is also suitable for:

Breezair ezq seriesBreezair exs seriesBreezair exq170

Table of Contents