Mitsubishi Electric MFXZ-KW25VG Operating Instructions Manual
Mitsubishi Electric MFXZ-KW25VG Operating Instructions Manual

Mitsubishi Electric MFXZ-KW25VG Operating Instructions Manual

Hide thumbs Also See for MFXZ-KW25VG:

Advertisement

Quick Links

FLOOR-T Y PE AI R CON DI T I ON ERS
INDOOR UNIT
MFXZ-KW25VG MFXZ-KW35VG MFXZ-KW50VG
For user
OPERATING INSTRUCTIONS
English
• To use this unit correctly and safely, be sure to read these operating
instructions before use.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MFXZ-KW25VG and is the answer not in the manual?

Questions and answers

Summary of Contents for Mitsubishi Electric MFXZ-KW25VG

  • Page 1 FLOOR-T Y PE AI R CON DI T I ON ERS INDOOR UNIT MFXZ-KW25VG MFXZ-KW35VG MFXZ-KW50VG For user OPERATING INSTRUCTIONS English • To use this unit correctly and safely, be sure to read these operating instructions before use.
  • Page 2: Safety Precautions

    ● OPERATING INSTRUCTIONS ● ENGLISH IS ORIGINAL ontents ■ Safety Precautions ■ Name of Each Part ■ Preparation Before Operation ■ Selecting Operation Modes ■ Fan Speed and Airflow Direction Adjustment ■ I-SAVE Operation ■ ECONO COOL Operation ■ Timer Operation (On/Off Timer) ■...
  • Page 3 To use this unit correctly and safely, be sure to read these operating instructions before use. afety Precautions Do not turn the breaker off except the case of burning smell, Do not operate the unit for more than 4 hours at high hu- midity (80% RH or more) and/or with windows or outside or when performing maintenance or inspection.
  • Page 4 ● OPERATING INSTRUCTIONS ● afety Precautions For installation Warning Consult your dealer for installing the air conditioner. • It should not be installed by the user since installation requires specialized knowledge and skills. An improperly installed air conditioner may cause water leakage, fire, or electric shock.
  • Page 5: Preparation Before Operation

    ame of Each Part reparation Before Operation Before operation: Insert the power supply plug into the power outlet and/or Remote controller turn the breaker on. Battery replacement indicator Page 4 Installing the remote controller batteries Signal transmitting section Operation Distance of signal : display section About 6 m Press the reset...
  • Page 6: S Electing Operation Modes

    ● OPERATING INSTRUCTIONS ● electing Operation Modes Auto mode (auto change over) The unit selects the operation mode according to the difference between the room temperature and the set temperature. During auto mode, the unit changes mode (cool mode↔heat mode) when the room temperature is about 2°C away from the set temperature for more than 15 minutes.
  • Page 7 an Speed and Airflow Direction Adjustment Air outlet selection to select the air outlet(s). Press When 2 flow is selected, air blows from the top and the front of the unit. When 1 flow is selected, air blows only from the top of the unit. (2 flow) (1 flow) The multi-flow vane is automatically set to the appropriate position.
  • Page 8: I -Save Operation

    ● OPERATING INSTRUCTIONS ● -SAVE Operation CONO COOL Operation Swing airflow (change of air flow) makes you feel cooler than stationary airflow. The set temperature and the airflow direction are automatically changed by the microprocessor. • A simplified set back function enables to recall the preferred (preset) setting It is possible to perform cooling operation with keeping comfort.
  • Page 9: Weekly Timer Operation

    eekly Timer Operation • A maximum of 4 on or off timers can be set for individual days of the week. • A maximum of 28 on or off timers can be set for a week. to set on/off, time, and Press , and E.g.
  • Page 10 ● OPERATING INSTRUCTIONS ● leaning I nst ruc t ions: • Switch off the power supply or turn off the breaker before cleaning. • Do not expose parts to direct sunlight, heat, or flames to dry. • Be careful not to touch the metal parts with your hands. •...
  • Page 11 i-Fi Module Setting Up The Wi-Fi module (optional parts) can be put inside the indoor unit. Refer to the installation manual for the detail. Setting up in WPS-PUSH mode This Wi-Fi module, communicates the status information and controls the com- mands from the MELCloud by connecting to an indoor unit.
  • Page 12 ● OPERATING INSTRUCTIONS ● i-Fi Module Setting Up Setting up in Access Point mode Register the information of the Router on the air condi- tioner. Complete the setting up in the Access Point mode within 10 minutes. In the displayed window, select Dynamic in DHCP (*1) and enter the information of Router, then tap the Sub- Access Point mode To enter the mode...
  • Page 13 • A small amount of refrigerant continues to flow The indoor unit which is not party Wi-Fi module or any third party Wi-Fi service with Mitsubishi Electric operating becomes warm and into the indoor unit even though it is not operating.
  • Page 14: W Hen You Think That Trouble Has Occurred

    ● OPERATING INSTRUCTIONS ● hen You Think That Trouble Has Occurred Symptom Explanation & Check points Symptom Explanation & Check points Outdoor unit Sound The fan of the outdoor unit • When the outside temperature is low during cool- Cracking sound is heard. •...
  • Page 15: Emergency Operation

    mergency Operation uto Restart Function If a power failure occurs or the main power is turned off during operation, “Auto When the remote controller cannot be used... Restart Function” automatically starts operation in the same mode as the one set Emergency operation can be activated by pressing the emergency operation with the remote controller just before the shutoff of the main power.
  • Page 16: Specifications

    ● OPERATING INSTRUCTIONS ● pecifications Guaranteed operating range Indoor Outdoor 32°C DB Upper limit 23°C WB N ot e : Cooling 21°C DB 1. MFXZ-KW has no specifi cations for single combination. Lower limit 15°C WB This indoor model is only for multi system air conditioner. *Note 1 As for the specifi cations of multi system, please confi rm 27°C DB...
  • Page 20 HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN DG79T881H01...

This manual is also suitable for:

Mfxz-kw35vgMfxz-kw50vg

Table of Contents