Page 2
1.1 Scope of this manual: This manual applies to the ELCO IO-Link signal Hub (16-bit M12, Metal housing): LKHA-16UP-M12G. Product overview: 1) LKHA-16UP-M12G Supply Voltage 24VDC, self-consumption max.100mA; 8 x Port module for 16 x Digital Input (Input Supply 8 x 24VDC/200mA) 16 x Digital Output (8 x 24VDC/500mA, max.
Page 3
1.4 Technical support: Please contact your local ELCO representative or call hotline if you have any questions about the products described in this manual. Additional information about ELCO products is available: Corporate name: Tianjin Elco Automation Co., Ltd Company address: No. 12, 4th XEDA Branch Road, Xiqing Economic-Technological...
Page 4
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. We assume no liability for product damage or subsequent damage arising from non-observance of the regulations or improper handling of the products. IO-Link Signal Hub~~LKHA-16UP-M12G 4 / 18...
Page 5
2.1 Datasheet IO-Link Signal Hub~~LKHA-16UP-M12G 5 / 18...
Page 6
2.2 LED indicator IO-Link signal hub indicator IO-Link comm. Indicator LK System power indicator P Digital channel indicator 0 Digital channel indicator 1 IO-Link Signal Hub~~LKHA-16UP-M12G 6 / 18...
Page 7
Us and Ua power OK Indicator 1.Expansion cable failure No power 2. Slave module is damaged 1.Signal overload or short circuit Abnormal signal 2.Slave module is damaged Signal / status Green Have signal Indicator No signal IO-Link Signal Hub~~LKHA-16UP-M12G 7 / 18...
Page 8
2.4 IO-Link signal hub dimensions IO-Link Signal Hub~~LKHA-16UP-M12G 8 / 18...
Page 9
2.5 Mounting the module Dimensions in mm Use screws that are suitable for the mounting surface structure. IO-Link Signal Hub~~LKHA-16UP-M12G 9 / 18...
Page 10
M12 connector Power supply 24V+ signal Signal input/output 1 Power supply GND signal Signal input/output 0 Function grounding FE 3)Wiring example a)Double PNP input signal – 1 connector connects 2 DI, LKHA-16UP-M12G support this connection. IO-Link Signal Hub~~LKHA-16UP-M12G 10 / 18...
Page 11
PNP output signal – 1 connector connects 2 DO, LKHA-16UP-M12G support this connection. c)PNP Input and output signal – 1 connector connects 1 DI and 1 DO. LKHA- 16UP-M12G support this connection. IO-Link Signal Hub~~LKHA-16UP-M12G 11 / 18...
Page 12
3.2 Signal address assignment The LKHA-16UP-M12G module is allocated 8 Byte Inputs and 2 Byte Outputs. Users can read the signal input and diagnostic status of the module through these datas, and control the signal output. 1)Process Data INPUT Mapping A total of 8 bytes (Bytes 0-7) of input data are occupied.
Page 13
Pin4 Pin2 Pin4 Pin2 Pin4 Byte 6~7(Ouptut warning) When the output port is not activated, the PIN of the port reads the input signal or detects voltage being supplied, the corresponding point indicates 1, IO-Link Signal Hub~~LKHA-16UP-M12G 13 / 18...
Page 14
Pin2 Pin4 Byte 1 Digital output status of port 4~7 Bit_7 Bit_6 Bit_5 Bit_4 Bit_3 Bit_2 Bit_1 Bit_0 Port7 Port7 Port6 Port6 Port5 Port5 Port4 Port4 Pin2 Pin4 Pin2 Pin4 Pin2 Pin4 Pin2 Pin4 IO-Link Signal Hub~~LKHA-16UP-M12G 14 / 18...
Page 16
Bit_7 Bit_6 Bit_5 Bit_4 Bit_3 Bit_2 Bit_1 Bit_0 Subindex Port7 Port6 Port5 Port4 Pin2 Pin2 Pin2 Pin2 3) Fault State Pin4 (Index: 0x42) Set the safety status of Pin4 output when communication fault occurs. “0”- Set to 0; IO-Link Signal Hub~~LKHA-16UP-M12G 16 / 18...
Page 17
Port4 Pin2 Pin2 Pin2 Pin2 4) Fault State Pin2 (Index: 0x43) Set the safety status of Pin2 output when communication fault occurs. “0”- Set to 0; “1”- Set to 1; “2”- Hold last value. IO-Link Signal Hub~~LKHA-16UP-M12G 17 / 18...