• Handle the module in a way that avoids breakage, scratching, bending of the glass and backsheet. Mitrex shall not be held responsible for damages of any kind, including – without limitation – bodily harm, injury or damage to property, in connection •...
Please ensure that all wiring is in perfect electrical and mechanical condition. 3.2 Wiring Requirements • Mitrex recommends that all wiring be double insulated with a minimum rating of 90°C (194°F). • All wiring should use a flexible copper conductor.
• Do not install modules in an enclosed space. • Connect module frames together using adequate grounding cables: • Failure to comply with these instructions will void Mitrex limited warranty. Mitrex recommends using 4-14 mm² (AWG 12-6) copper wire. • All bolts, nuts, flat washers, lock washers and other relevant hardware 4.3 Bifacial Modules...
• The module may be fastened to a support by using clamps on a minimum of four points on two opposites sides. • Clamps should be positioned according to the authorized position ranges as defined in the Appendix. • Clamps should be positioned symmetrically. mitrex.com...
Electrical characteristics have tolerance of +/- 5% under STC conditions. 5.3 Temperature Specifications Specifications All Above Modules Temperature Coefficient Voc -0.262% / °C Temperature Coefficient Isc 0.054% / °C Temperature Coefficient Pmax -0.341% / °C Nominal Module Operating 42.5 ± 2°C Temperature mitrex.com...
Page 8
Installation Manual Framed Solar Modules General Product Datasheet T oll Free +1 (855) 254 0214 Learn More mitrex.com info@mitrex.com Headquarters 41 Racine Rd, Toronto, ON M9W2Z4, Canada +1 (416) 497 7120 USA Office Chrysler Building, 405 Lexington Avenue Floor 26, New York, USA, 10174 +1 (646) 583 4486 mitrex.com...