MITREX M A1F Series Installation Manual

Frame solar modules
Hide thumbs Also See for M A1F Series:

Advertisement

INSTALLATION MANUAL
FRAME SOLAR MODULES
Mxxx-A1F - Mxxx-B1F - Mxxx-yyyy1F
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M A1F Series and is the answer not in the manual?

Questions and answers

Summary of Contents for MITREX M A1F Series

  • Page 1 INSTALLATION MANUAL FRAME SOLAR MODULES Mxxx-A1F - Mxxx-B1F - Mxxx-yyyy1F...
  • Page 2 1. SAFETY PRECAUTIONS & HANDLING OF MODULES ......03 1.1 Manual Disclaimer 1.2 Limitation Of Liability 1.3 General Information 1.4 General Warning 2. PRODUCT INFORMATION .................. 04 2.1 Product Certifications 2.2 Limited Warranty 2.3 Technical Specifications 3. ELECTRICAL INSTALLATION ................04 3.1 General Information 3.2 Wiring Requirements 3.3 Series Connection...
  • Page 3  current from the modules or an external source is The information presented in this manual present. is subject to change by Mitrex without prior notice. Mitrex gives no warranty of any kind Always use appropriate Personal Protective  whatsoever, either explicitly or implicitly, with Equipment when installing PV modules.
  • Page 4: Electrical Installation

    When installing modules, connector should be 2.2 LIMITED WARRANTY connected to each other as soon as possible or Mitrex provides a 25-year hardware warranty, and appropriate measures should be taken to avoid we guarantee that after 25 years, the efficiency of moisture and dust penetrating into the connector.
  • Page 5: Wiring Requirements

    3.2 WIRING REQUIREMENTS than reported at standard test conditions. Mitrex recommends that all wiring be double  The requirements of the National insulated with a minimum rating of 90°C (194°F).
  • Page 6: Site Considerations

    4.2 SITE CONSIDERATIONS maintenance of the system in accordance with Mitrex Solar Modules should be mounted in a all national, state and local electrical codes and location that meets the following requirements.
  • Page 7 When installed on a roof, solar modules must - 80 mm (3.15 in) when 2400 Pa < uplift load ≤  be mounted over a fire-resistant roof covering 54000Pa is required. rated for the application. The fire resistance of the - 40 mm (1.57 in) when uplift load ≤...
  • Page 8: Mechanical Specifications

    5. APPENDIX 5.1 ELECTRICAL SPECIFICATIONS SOLAR PANEL - Mxxx-A1F - Mxxx-B1F SOLAR ROOF - Mxxx-RF041F Electrical characteristics have tolerance of +/- 5% under STC conditions. C: Correction factor 5.2 MECHANICAL SPECIFICATIONS T (°C): Ambient temperature α (%/°C): Temperature coefficient of the selected module.
  • Page 9 A = (250 – 450) mm Uplift Load ≤ 5400 Pa Downforce Load ≤ 5400 Pa Clamp configuration CL2 – 4 point installation, mounting rails parallel to long edge of PV module.

Table of Contents