Advertisement

Quick Links

This manual is designed for the use of FCAR products; it
cannot be copied or stored in any form (electronic,
mechanical, photocopying, recording or otherwise) without
prior written permission being secured from Shenzhen
FCAR Technology Co., Ltd.
This manual is intended for professional vehicle repair
technicians.
This manual provides the operation methods for FCAR
products only, and the company accepts no responsibility
for the consequences caused by attempting to use the
operation methods on other equipment.
The company shall not accept any responsibility for
accidents caused either by the user personally or anyone
else, or costs and expenses due to equipment damages
including equipment loss caused by the user's abuse or
misuse, arbitrary changes or repairs or operation of the
equipment in a manner not in accordance with the manual
requirements.
This manual is written in accordance with the existing
configuration and functions of the product, and is subject to
change
configurations and functions.
If you have any questions, please contact us by the
following ways:
Headquarters: 8F, Chuangyi Bldg., No. 3025 Nanhai Ave.,
Nanshan, Shenzhen, China 518060
Statement
without
notice
if
the
product
1
HDS600
adds
new

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HDS600 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fcar HDS600

  • Page 1 HDS600 Statement  This manual is designed for the use of FCAR products; it cannot be copied or stored in any form (electronic, mechanical, photocopying, recording or otherwise) without prior written permission being secured from Shenzhen FCAR Technology Co., Ltd.
  • Page 2 The trademarks, service marks, domain names, logos, company names or other companies mentioned may not be used without prior written permission of the owner. FCAR Series Host Machine Maintenance and Use Cautions  Do not allow unauthorized disassembly.
  • Page 3 HDS600 to operate. Be especially careful to avoid impact or damage caused by environmental factors such as the surrounding pH, poison gas or high pressure environment.  Vehicle battery fluid contains sulfuric acid, which is corrosive to the skin. During the operation, avoid direct contact with the battery fluid, in particular being careful not to splash into the eyes.
  • Page 4 HDS600  When using FCAR series products for testing, please be gentle and keep them away from heat and electromagnetic fields, to avoid interference to the main unit.  Do not use sharp tools to click the screen; the matched touch pen is recommended.
  • Page 5 HDS600 correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Page 6: Table Of Contents

    HDS600 CONTENTS PRODUCT OVERVIEW ......... 7 PRODUCT STRUCTURE ........... 7 HOST CONFIGURATION ........... 9 PRINTER CONFIGURATION (OPTIONAL)....10 POWER ON/OFF ..........10 POWER ON ..............10 POWER OFF ............. 11 VEHICLE DIAGNOSTIC PREPARATION ... 11 INTRODUCTION OF EACH FUNCTION MENU . 14 DIAGNOSTIC FUNCTION ........
  • Page 7: Product Overview

    HDS600 1. PRODUCT OVERVIEW The HDS600 Code Pro is the latest in Fcar’s line of professional grade code scanners for the Commercial Vehicle market. It covers light, medium and heavy duty vehicles, for reading & clearing codes, live data and special functions.
  • Page 8 HDS600...
  • Page 9: Host Configuration

    HDS600 Serial No. Name Function Description Used to connect to an external USB Port ① computer Used to connect to the vehicle or DB-15 Interface ② the power adapter Display content and touch Touch Screen ③ operation area Paper socket Printer paper socket ④...
  • Page 10: Printer Configuration (Optional)

    HDS600 PRINTER CONFIGURATION (OPTIONAL) Printer 80mm thermal printer Print speed 60mm/s Effective print width 72mm 203dpi 1mm=8dots Print resolution Print paper 80mm*30mm specifications 2. POWER ON/OFF The device is provided with a main diagnostic test line, which has three interfaces: DB-15 interface, OBD interface and DC power interface.
  • Page 11: Power Off

    HDS600 automatically. Note: the voltage of the power supply should be within the scope of application of the product equipment. If it is beyond the scope, the product may be damaged. POWER OFF Before powering off, please stop all diagnostic procedures and return back to the main interface.
  • Page 12 HDS600 device DB-15 connector and tighten the retaining screws. The other end is connected to the vehicle's OBD interface. Note: Before the equipment is connected to the vehicle, it is necessary to judge whether the diagnostic port of the vehicle is a standard OBD-II interface or a non-standard OBD-II interface.
  • Page 13 HDS600 2) Connection of non OBD-II interface Vehicles with non OBD-II interface need to connect the main test line with the corresponding special connector, as shown in the figure: Note: at this time, the equipment is powered by the vehicle...
  • Page 14: Introduction Of Each Function Menu

    HDS600 not, it may be that the vehicle diagnostic port has no power supply, in which case the equipment should be powered by the cigarette lighter or battery clip. 4. INTRODUCTION OF EACH FUNCTION MENU After the system is started, the main menu of function will be entered.
  • Page 15 HDS600 Used to report the problem to the company's service system (need to Feedback connect to the network) when the system cannot be accessed during the diagnosis process Used to print test results or test reports. Print The printer is optional...
  • Page 16 HDS600 Table 2: Function sub menu Function Icon Function description name Measures the voltage of 16 PIN of OBD Pin detecting diagnostic interface, and judges the pin position of K- line and CAN line. Report Browse and manage the test report files...
  • Page 17: Diagnostic Function

    HDS600 Table 3: Function main menu Icon Function name Function description Diesel OBD Diagnostic procedure: Diesel OBD OBD-II Diagnostic procedure: OBD-II DPF regeneration and maintenance (Pin Detect)For the measurement of Tools pin voltage of diagnostic interface Data For browsing and managing saved...
  • Page 18 HDS600 2) Select connector according to the specific situation, such as 【Diesel6&9PIN】; 4) Select the required diagnostic method, such as 【Standard protocol(Fast Scan)】;...
  • Page 19 HDS600 5) Click 【Start test】 6) Select【(J1939) Engine】;...
  • Page 20 HDS600 7) Enter【Diagnosis home page】; The main diagnostic interface usually includes the following options: Read ECU Information: Read and display the control system module information detected from ECU Read Fault Code: Read the fault code information retrieved from the vehicle system module...
  • Page 21: Pin Detect

    HDS600 retrieved from the vehicle system module Live Data: Read and display the real-time operation parameters of the current system module 6. PIN DETECT This function mainly measures the voltage of 16 PIN of OBD diagnostic interface, and judges the pin position of K- line and CAN line.
  • Page 22: Diagnostic Software Upgrade

    HDS600 8. DIAGNOSTIC SOFTWARE UPGRADE By connecting the device to a wireless network, the diagnostic software can be upgraded. Open 【Update】 in the function main menu, and the system will automatically search for the latest update program, as shown in the figure below. Click 【Update】...
  • Page 23: Settings

    HDS600 9. SETTINGS Select 【Settings】 from the main menu to open the setting interface, where you can adjust the following system settings: WIFI CONNECTION The device supports wireless network connection for diagnostic software upgrade and problem feedback.
  • Page 24: Brightness

    HDS600 BRIGHTNESS The device supports screen brightness setting, please adjust it according to your preference. VOLUMES The device supports volume adjustment.
  • Page 25: User

    HDS600 USER 1) Activate The products are not activated when they leave the factory. Connect the device to a Wi-Fi network, and click 【Activation】 to activate it. Note: Please ensure that the device is connected to an effective Wi-Fi before performing the activation operation.
  • Page 26: Storage

    HDS600 2) User Info Set your personal information: name, telephone, email, address, etc. STORAGE Cleaning up useless data with one click, freeing up more space and cleaning up regularly will help the system run more stable.
  • Page 27: General

    HDS600 GENERAL Set the general information or look up the device information. Language Please select settings based on the language you support for the model you purchased. Unit...
  • Page 28: Printer Introduction

    HDS600 This option is used to set the data flow unit in the diagnostic equipment software. Please select metric system or English system as required. Date &Time This option is used to set the date / time of the device. The default is automatic network synchronization update, or it can be set manually.
  • Page 29 HDS600 Take out the paper roller upward first, and then the paper bail.
  • Page 30 HDS600 Insert the roller into the print paper. Put the paper into the socket first, and draw a part of paper, then put the paper bail on the paper and clip it into the socket. Note: Pay attention to the direction of the paper. If the...
  • Page 31: Printer Self Test Function

    HDS600 Close the cover. 10.2 PRINTER SELF TEST FUNCTION When the machine is turned on, press the printer test key briefly, and the printer will automatically print out a piece of blank paper.
  • Page 32 HDS600 In the case of power on, long press the printer test key for three seconds, the printer will automatically print a section of self-test content, indicating that the printer function is normal.
  • Page 33 HDS600 WARRANTY CLAUSES Thank you for choosing FCAR Code Pro. In order to make the best use of the product, we recommend that you follow all recommendations for maintenance, storage, and operation in accordance with the user manual's instructions at all times.
  • Page 34 1.) Failures, defects or flaws not directly related to the quality of the FCAR products, including but not limited to failing to use the product according to the user manual’s instructions, crash, fall, disassembly by anyone other than a FCAR approved service...
  • Page 35 8. Within the product warranty period and under this warranty clause, you can obtain free warranty service for losses due to product defects. FCAR shall not be liable for your direct or indirect loss. 9. All product warranty information, product functions and specification changes will be posted on FCAR latest promotional materials and the official website.
  • Page 36 HDS600...

Table of Contents