Page 1
WENZHOU BRIDGE INDUSTRIAL ZONE,BEIBAIXIANG TOWN, ZHEJIANG, CHINA TEL: +86-577-5717 7008 FAX: +86-577-5717 7007 VERSION: 20230612 benyi@zjbeny.com www.beny.com This catalogue has been printed on ecological paper. Zhejiang Benyi New Energy Co.,Ltd.all rights reserved. WWW.BENY.COM If the models and specification in this product catalogue is changed due to the change of products, we wil not inform.
Please turn off the hybrid electric vehicle before charging it. BENY Electric, namely Zhejiang Benyi Electric Co., Ltd., offers reliable and robust EV fast chargers with attractive designs that are easy to operate. We are a leading brand, annually producing thousands of quality DC protection products and EV charging stations for solar photovoltaic, battery energy storage, and EV charging systems.
≤±0.5 Voltage accuracy ≥30A: ≤±1%,<30A: ≤±0.3A Accuracy of current Voltage regulation accuracy ≤±0.5%(150~1000V, 0~20MHz) Accuracy of a steady flow ≤±0.5%(output load 20%~100%rated range) Ripple coefficient Effective value: ≤±0.5 Peak: ≤±1 Standby power consumption ≤0.1% rated output power BENY 03/04...
Installation inclination shall not exceed 5%. flexible configuration, easy maintenance, single module failure does not affect the system, Keep inflammable and explosive materials away from the charger. greatly improve system reliability and stability. Atmospheric pressure should be 79kPa ~ 106kPa. BENY 05/06...
Rated input voltage Input format (Test range is Load adjustment rate ≤±0.5% Three phase+PE 320V~530V) AC input voltage range 260Vac 530Vac Grid adjustment rate ≤±0.1% ≤10% Three-phase unbalance AC input voltage frequency 45Hz 65Hz BENY 07/08...
10kW. Ambient temperature: 75°C, the output power of the module drops to When the fan breaks down, Cooling Fan failure the module shuts down, the red light is on, and the fault is protection reported. BENY 09/10...
The fault information can be displayed on the status indicator or the display screen, and the charging pile failure, such as monitoring and control unit can send out sound and light alarm, fault information can be recorded. and output through the communication port charging pile on the screen. BENY 11/12...
You may swipe the card or input password for charging after that. When the charging connector is inserted into the outlet, the indicator light turns green, meaning the power is on. Please do not remove or insert the charging connector at this time to prevent electric shock. BENY 13/14...
Before charging an electric vehicle, read the instructions and electric vehicle owner's Always-on LED light: It is on for charging and off for shutoff. manual that came with the charging post. Red light: It is on when a fault occurs and off after troubleshooting. BENY 15/16...
As the ventilation outlet is located at the back of the charging station, the free space must be ventilated accordingly. (2)Remove wooden boxes on the front and rear. For indoor use, the room must have ventilation exceeding 3000 m³/h. BENY 17/18...
The charger can be transported by forklift. 4.5.2 Carry by crane Cranes can transport chargers. Four mounting holes are reserved at the top for rings. (1)Tighten the four rings (4)Remove the bottom tray (2)Install a hook and sling BENY 19/20...
75mm. (2)The embedded pipeline for the foundation should conform to the hole size of the bottom plate of the charger to avoid inconsistency between the pipeline and the hole. 4-15x35 50x120 front BENY 21/22...
Ethernet cable Switch in WAN/LAN (external cable); LAN1 Switch in the OCPP Ethernet cable (internal cable). Router power supply 12V (factory default settings) 3G/4G Switch in 4G antenna WIFI/DIN Switch in WIFI antenna 1.2g/3g/4g SIM card slot BENY 23/24...
Page 15
(2) Enter the password, which defaults to 1 (4) Fill in the OCPP server address (3) Enter the OCPP settings interface (5) Fill in the pile number of the charger BENY 25/26...
5.2 Parameter configuration (see attachment parameter setting and whole charger debugging) 5.3 Technical Data The input features Projec T technical requirements Voltage range 400 Vac plus or minus 10% wiring 3P+N+PE frequency 50/60Hz BDC30 BDC40 BDC60 BDC80 BDC90 BDC120 ≥46A ≥61A ≥92A ≥122A ≥138A ≥184A...
Note: The power provided by the charging station depends on several factors: ·Vehicle battery voltage ·Vehicle battery temperature ·Vehicle load level output characteristic output current(A) ·The environment temperature High-pressure mode Maximum output power 1200 1200 1000 1000 output characteristic output characteristic output current(A) output current(A) BENY 29/30...
Page 18
≤2000m NBT 33008.1-2018 Units of size: mm (L*W*T) 800 * 800 * 2000 China NBT 33001-2018 Package size, units: mm (L*W*T) EN61851-1:2011;EN61851-23:2014 Weight of charger ≤350 The European Union IEC61851-21-2:20018;EN61000-6-2:2005;EN61000-6-4:2007+A1 Total Weight, including packing ≤400 Dark grey Color BENY 31/32...
Supporting devices such as backup of common spare components and installation tools can Do not stack wet Do not shake be attached based on customer requirements. Technical documents: Instruction Manual, Certificates of qualification, warranty card, factory inspection report. BENY 33/34...
Max. Output Current the module is normal. 2, the module IP Rating Output Power started, but the board did not detect the battery voltage. Number: Made in china It may be a wiring error. Manufacturing Year November 2022 BENY 35/36...
Page 21
The charge in the The car end failure other faults of the BMS BSM packet stops and stops charging after 10 minutes E019 Charger code input The charger/ Customer special does not conform to the platform customization rules function BENY 37/38...
Page 22
(such as set time, its maximum intercepting packets allowable charging fixed time, etc.) voltage. E027 The output HV fuse is The charger The main control unit Check the fuse entry faulty has detected the loop abnormal opening of the HV fuse BENY 39/40...
Page 23
- module input setting - set the manufacturer has lightning arrester not set. maintenance switch on number as 25the 5 to restart. BENY 41/42...
Page 24
CAN E065 Incorrect account Password communication password mistake line;If the machine is not a split pile, E066 Server login Failure platform The platform does change the control not recognize the mode and the charger machine type. BENY 43/44...
Page 25
- input process. If there is no setting, and restart. actual output, it is necessary to test whether the DC circuit of the charging pile is short circuit or whether the voltage collection line is connected incorrectly. BENY 45/46...
Page 26
2. Replace the car is consistent with for test charging. the actual amount of the meter; 3. Try charging an electricity meter. BENY 47/48...
Page 27
The vehicle E106 The BST output Find the cause of not delivered with the battery voltage sent connector is thought the actual;2, if not, over temperature by the BMS. charging connector overheated calibrate the battery was overheated voltage. BENY 49/50...
Page 28
If the abnormal actual output current is greater than the BMS demand current, compare the meter current to see if it is consistent. BENY 51/52...
Page 29
BMS vehicle. timeout factor to 2 on the LCD screen of the charger to be compatible with this vehicle. BENY 53/54...
Page 30
If the judgment is plugged in tightly, change the car to tr; iff the charging is no problem, it is the car socket has a problem, it is recommended to repair the vehicle. BENY 55/56...
LCD screen, (constant voltage) and you can set it. nor 2 (constant current), which is an invalid value. Temperature and The charger E139 humidity fault E140 Charging SOC The charger completed Appendix II Electrical Schematic Diagram BENY 57/58...
Need help?
Do you have a question about the BDC30 and is the answer not in the manual?
Questions and answers