LEM-1DL Supplemental Instructions
- REFER TO INSTALLATION MANUAL INSIDE LEM-1DL BOX FOR STANDARD
The LEM-1DL master station provides communication to and from a door station, and has a separate button
for door release. This supplemental instruction manual addresses many of the additional functions and
modifications for the LEM-1DL system, including installation and troubleshooting information.
MASTER STATION:
LEM-1DL:
1-call master station with "Normally Open" door release button
DOOR STATIONS: (Note: Door stations are weather resistant, made for outdoor use)
LE-D:
Surface mount, plastic door station (included with LEM-1DLS Set)
LE-DA:
Flush mount in 2-gang box, stainless steel cover
LS-NVP/C:
Vandal resistant flush mount in 3-gang box, white powder-coat finish
LE-SS/A:
Vandal resistant flush mount sub in 2-gang box, stainless steel
LE-SSR:
Vandal resistant, red mushroom button, flush mount in 2-gang box,
stainless steel
LE-SS-1G:
Vandal resistant flush mount sub in 1-gang box, stainless steel
OPTIONAL COMPONENTS & ACCESSORIES:
RY-AC/A:
External signaling relay (Requires 12VDC power supply)
DAK-2S:
Dual master adaptor kit
(1 per 2 master stations. Use 2 DAK-2S for up to 4 total master stations)
SBX-NVP:
Surface mount box for LS-NVP/C
SBX-2G:
Surface mount box for LE-SS/A, LE-SSR, LE-DA
SBX-1G:
Surface mount box for LE-SS-1G
EL-12S:
Door strike (for interior wood frame doors only)
PT-1210N:
AC 12V Transformer (used for door strike and for each master station)
PS-1225UL:
12V DC Power Supply, 2.5A, UL Listed
822202:
2 conductor, 22AWG, Shielded wire
(Available in 500' and 1000' boxes)
Install two separate runs of this cable, one for the intercom and one for
the door release.
DOOR RELEASE WIRES MUST BE IN A SEPARATELY JACKETED CABLE FROM THE INTERCOM WIRING.
LEM-1DLS Set contains:
LE-D
LE-D
1 LEM-1DL, 1 LE-D, 1 PT-1210N.
Door strike not included.
2 cond. shielded for intercom
EL-12S
3-1/2"
1-1/8"
Separate 2 conductor for door release
If using a non-Aiphone door strike, use separate power
!
source for door release mechanism.
13/16"
Single Master Station with Door Release
INSTALLATION INFORMATION -
#90111
0112
LEM-1DL
LEM-1DL, LEM-1DLC
Power
Source
5-5/8"
for Strike
LEM-1DL
LE-D
LE-DA
LS-NVP/C
LE-SS/A
DAK-2S
(2 component modules per kit)
PT-1210N
PT-1210N
2-7/8"
1-15/16"
2-3/16"
LEM-1DL Supplement
Pg. 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the LEM-1DLC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aiphone LEM-1DLC

  • Page 1 2 cond. shielded for intercom PT-1210N PT-1210N EL-12S 3-1/2" 1-1/8" Power Source Separate 2 conductor for door release 2-7/8" 1-15/16" 5-5/8" 2-3/16" for Strike If using a non-Aiphone door strike, use separate power source for door release mechanism. LEM-1DL Supplement 13/16" Pg. 1...
  • Page 2 Module Module Leave E/- jumper PT-1210N PT-1210N attached EL-12S If using a non-Aiphone door strike, use a separate power source for the door release mechanism. 13/16" Aiphone EL-12S IMPORTANT!!! Each master REQUIRES an individual power supply. OPERATION NOTES: 1. Only one master can be used at a time.
  • Page 3 Note: For applications requiring a Normally Closed (N/C) contact (Magnetic locks, etc.), an external relay should be chosen based on the lock’s power source. - When using a 12-18V DC magnetic lock, Aiphone’s RY-18L relay may be used. - For 24V DC magnetic locks, Aiphone’s RY-24L relay may be used.
  • Page 4 12-16V AC or 12-24V DC. when pressing the talk button. masters. Aiphone recommends the PT-1210N. Ensure that the intercom wire is run at least 20” from any AC electircal wire, or crossed at 90 degrees. Intercom wire should be shielded, with the drain wire connected to an earth ground Intercom wiring run close to AC wiring.