VAV Compact Controller KNX / PL-Link
G..B181..KN
CE1N3547en_g
2024-03-11
VAV Compact Controller 5 / 10 Nm with KNX communication
GDB181..KN with 5 Nm nominal torque
GLB181..KN with 10 Nm nominal torque
Operating voltage AC 24 V
KNX S-Mode, LTE-Mode, and PL-Link
For plants with variable or constant air-volume flow
Actual values for volume flow, damper position and differential pressure
Operating modes for volume flow control or position control
Siemens
Smart Infrastructure

Advertisement

loading
Need help?

Need help?

Do you have a question about the G B181 KN Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siemens G B181 KN Series

  • Page 1 KNX S-Mode, LTE-Mode, and PL-Link • For plants with variable or constant air-volume flow • Actual values for volume flow, damper position and differential pressure • Operating modes for volume flow control or position control CE1N3547en_g Siemens 2024-03-11 Smart Infrastructure...
  • Page 2 How to obtain documentation and product-related software Related documents such as environmental declarations, CE declarations, etc., can be down- loaded at the following Internet address: http://siemens.com/bt/download The ETS device profile can be downloaded at the following Internet address: http://siemens.com/hvac-td The ACS931 and ACS941 softwares can be downloaded at the following Internet address: https://support.industry.siemens.com...
  • Page 3 European Directive and may not be disposed of as do- mestic garbage. • Dispose of the device through channels provided for this purpose. • Comply with all local and currently applicable laws and regulations. 3 / 12 CE1N3547en_g Siemens 2024-03-11 Smart Infrastructure...
  • Page 4: Push-Button Operation

    (cf. equipment combinations) can be connected to the PPS2 interface. Connection to the PPS2 interface AST20 (or PC with ACS931 / ACS941 over AST22) G..B181.1E.. or ASV181.1E/3 Strain release strip Connection cable (7-pin) 4 / 12 Siemens CE1N3547en_g Smart Infrastructure 2024-03-11...
  • Page 5 500m steps n*500m value closest to local altitude) Elevation asl. Adaptation must not be activated while a device jam is present Value used for displaying / not used for volume flow control loop 5 / 12 CE1N3547en_g Siemens 2024-03-11 Smart Infrastructure...
  • Page 6 On / Off Direction is writable (OEM parameter protection applies), otherwise it is read-only. Adaptation must not be activated while a device jam is present Override position 1 has priority over Override position 2 6 / 12 Siemens CE1N3547en_g Smart Infrastructure 2024-03-11...
  • Page 7 0...3.16 OEM-Reset Receive 1.017 _Trigger 1 bit 0, 1 = Trigger For some group objects, alternative data point types (DPT) can be selected in ETS. The first entry indicates the default setting. 7 / 12 CE1N3547en_g Siemens 2024-03-11 Smart Infrastructure...
  • Page 8 Actual value of the differential pressure over the VAV box measuring cross. 18 Coefficient VAV box characteristic value to map a nominal differential pressure to the corresponding nominal volume flow. 19 OEM-Reset Resets all parameters to the value specified by the OEM. 8 / 12 Siemens CE1N3547en_g Smart Infrastructure 2024-03-11...
  • Page 9: Technical Data

    5…95 % r. F. Humidity (non-condensing) Transport Climatic conditions Class 2K3 -25…70 °C Temperature Humidity 5...95 % r. h. Storage Climatic conditions Class 1K3 -5…45 °C Temperature Humidity 5...95 % r. h. 9 / 12 CE1N3547en_g Siemens 2024-03-11 Smart Infrastructure...
  • Page 10 ± 4.5 % of the measured value Amplitude mounting position ± 0.1 Pa / Year Drift 3000 Pa Max. permissible operating pressure 3000 Pa Max. permissible overload on one side The documents can be downloaded from http://siemens.com/bt/download 10 / 12 Siemens CE1N3547en_g Smart Infrastructure 2024-03-11...
  • Page 11 Safety transformers with twofold insulation as per EN 61558 required; they must be designed to be on 100 % of the time. Dimensions G..B181.1E.. min. 100 3547M01 Ø 3...8 8 - 16 mm 12.8 mm min. 80 15 mm Measurements in mm 11 / 12 CE1N3547en_g Siemens 2024-03-11 Smart Infrastructure...
  • Page 12 Issued by © Siemens Switzerland Ltd, 2017 Technical specifications and availability subject to change without notice. Siemens Switzerland Ltd Smart Infrastructure Global Headquarters Theilerstrasse 1a 6300 Zug Switzerland Tel. +41 58-724 24 24 www.siemens.com/buildingtechnologies Document ID CE1N3547en_g Edition 2024-03-11...