Start
Up Conditions
Thermal
Expansion
Property
Damage
Hazard
• Avoid water heater damage.
• Install thermal
expansion
tank or device
if necessary.
= Contact
qualified
installer
or service
agency.
Water supply
system
may, because
of such events
as high line
pressure,
frequent
cut-offs and the effects
of water hammer
have
installed devices
such as pressure
reducing
valves, check valves,
back flow preventers,
etc., to control
these
types
of problems.
When
these
devices
are not equipped
with an internal
by-pass,
and no other measures
are taken,
the devices
cause the water
system
to be closed.
As water
is heated,
it expands
(thermal
expansion)
and closed
systems
do not allow for the expansion
of heated
water.
The water within the water heater tank expands
as it is heated
and
increases
the pressure
of the water system.
If the relieving
point
of water
heater's
temperature-pressure
relief valve
is reached,
the valve
will relieve
the excess
pressure.
The
temperature-
pressure
relief
valve
is not intended
for the constant
relief
of thermal
expansion.
This
is an unacceptable
condition
and
must be corrected.
It is recommended
that
any
devices
installed
which
could
create
a closed
system
have a by-pass
and/or
the system
have
an expansion
tank
or device
to relieve
the pressure
built by
thermal
expansion.
Thermal
expansion
tanks are available
from
Sears
stores
and through
the Sears
Service
Centers.
Contact
the local
plumbing
inspector,
water
supplier
and/or
the Sears
Service
Center
for assistance
in controlling
these
situations,
see Figure
34.
Thermal
Expansion
Tank Specifications
Model
Number
I53.331020
I53.331050
Tank
Capacity
In Gallons
2
5
Dimensions
Pipe
in Inches
Fitting
Diameter
Length
On Tank
8 (203 ram)
12-3/4 (323 ram)
3/4" Mate
11 (279 ram)
14-3/4 (375 ram)
3/4" Mate
Expansion
Tank
Capacity
Needed
Expansion
Tank Sizing Chart
Inlet*
Water Heater Capacity
(Gallons)
Water
Pressure
30
40
50
66
82
40 psi
2
2
2
5
5
50 psi
2
2
2
5
5
60 psi
2
2
2
5
5
70 psi
2
2
5
5
5
80 psi
2
5
5
5
5
*Highest
recorded
inlet water
pressure
in a 24 hour period
or
regulated
water
pressure.
NOTE:
Expansion
tanks
are
pre=charged
with
a 40 psi air
charge.
If the inlet water
pressure
is higher
than
40 psi, the
expansion
tank's
air pressure
must
be adjusted
to match
that pressure,
but must
not be higher
than
80 psi.
WATER HEATER
(3)
Hr_r
r,n/r_
/
COLD WATER
PRESSURE
_,,
-_v_%/,_
INLET FiTTiNG
REDUCING
r_
_
_
VALVEWiTH
I I
BY-PASS
PRESSURE
GAUGE
WATER
SHUT-OFF
.
RECOMMENDED
INSTALLATION
(VERTICAL MOUNTING)
WATER
HEATER
COLD
WATER
INLET
FiTTiNG
HOT
COLD
(3)
PRESSURE
REDUCING
VALVEWiTH
(t)
BY-PASS
EXPANSION
j
TANK_
PRESSURE GAUGE
_NLETCOLD
WATER SHUT"OFF
ALTERNATE
RECOMMENDED
iNSTALLATION
(HORIZONTAL
MOUNTING)
FIGURE 34,
Strange Sounds
Possible
noises
due to expansion
and contraction
of some metal
parts during
periods
of heat-up
and cool-down
do not represent
harmful
or dangerous
conditions.
Condensation
causes sizzling
and popping within the burner area
during
heating
and cooling
periods
and should
be considered
normal.
See Condensation
section.
Draft Hood Operation
Check
draft
hood
operation
by
performing
a worst
case
depressurization
of the building.
With
all doors
and windows
closed,
and with
all air handling
equipment
and exhaust
fans
operating
such
as furnaces,
clothes
dryers,
range
hoods
and
bathroom
fans,
a match
flame
should
still be drawn
into the
draft hood of the water
heater with its burner
firing.
If the flame
is not drawn
toward
the draft hood
after
15 minutes
of burner
operation,
shut off water
heater
and make necessary
air supply
changes
to correct.
26