Download Print this page

AG SPRAY STS-EZ-METER 5283077 Owner's Manual

Smart transfer systems for chemical and surfactant induction
Hide thumbs Also See for STS-EZ-METER 5283077:

Advertisement

Quick Links

(STS - Smart Transfer Systems for chemical and surfactant induction.)
Model: 5283077
STS-EZ-METER 4-Product
BEFORE RETURNING THIS PRODUCT
FOR ANY REASON, PLEASE CALL
BAKERSFIELD, CA
COLUMBUS, NE
877-724-2236
800-274-1025
FARGO, ND
HOPKINSVILLE, KY
701-280-2862
800-637-7172
NEWTON, KS
PASCO, WA
800-394-7662
800-634-2026
If you should have a question or experience a problem with
your Ag Spray Product: Visit our website @ www.agspray.com or
call the Toll free number above. Our technical support
representatives will be happy to help you.
In most cases a customer service rep. can resolve
the problem over the phone.
To obtain prompt, efficient service, always remember to give the
following information....
• Correct Part Description and/or part number
• Model number and Serial Number
Part descriptions and numbers can be obtained from the
illustrated parts list section(s) of this manual.
Retain a copy of your receipt for your unit,
as it will be required to validate any warranty service
Products are warranted against manufacturer or workmanship
defects for one year from date of purchase for home owner
usage and 90 days for commercial usage.
OWNER'S MANUAL
STS-EZ-METER System
DOTHAN, AL
800-227-4098
MANKATO, MN
507-388-6295
TEMPE, AZ
877-974-7166
Model: 5283078
STS-EZ-METER 6-Product
General Information
Thank you for purchasing this product. The purpose of this
manual is to assist you in operating and maintaining your
newly purchased product.
www.agspray.com
[5195991
(02/24)]
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the STS-EZ-METER 5283077 and is the answer not in the manual?

Questions and answers

Summary of Contents for AG SPRAY STS-EZ-METER 5283077

  • Page 1 800-634-2026 877-974-7166 If you should have a question or experience a problem with your Ag Spray Product: Visit our website @ www.agspray.com or call the Toll free number above. Our technical support representatives will be happy to help you. In most cases a customer service rep. can resolve the problem over the phone.
  • Page 2 Table of Contents Operation & Safety Information 5-11 Installation & Basic Operations Instructions STS-EZ-METER System 4-Product (5283077) Breakdown STS-EZ-METER System 6-Product (5283078) Breakdown Limited Warranty Page 2...
  • Page 3 Important Operation & Safety Information WARNING Read and understand this owner’s manual completely before using the Meter System. Read each chemical label’s instructions before handling the chemical. Improper use of the meter or handling of chemicals could result in serious injury or illness for the operator or nearby persons/animals, or cause damage to the environment.
  • Page 4 ------------------------- BEFORE SEASONAL USE ---------------------------- • CHECK and TEST Meter System with water before adding chemical. Temperature change can cause material fitting expansion/contraction. Serious injury could result from chemical leaks. • REPLACE any worn or frayed hoses. Hose failure can result in serious damage. •...
  • Page 5 Installation & Basic Operation The STS-EZ-METER System is designed to integrate with an STS Inductor system, models STS-402E (5281633), STS- 403E (5282634), STS-652E (5281635) and STS-653E (5281636) which are equipped with Eductor Venturi plumbing kits, which are designed to be plumbed on the output or pressure side of your transfer pump. DO NOT reduce or restrict flow after the Venturi.
  • Page 6 METER DISPLAY OPERATION 2. OPERATION 2.1 Accumulative Total Accumulative total can be reset in the program mode. The accumulative total is displayed by pressing the ACCUM TOTAL key. 2.2 Resettable Total The resettable total display remains visible at all times and may be reset at any time by pressing the reset button for 2 seconds. 2.3 Rate Display The second line display toggles between Rate and Accumulative Total as the appropriate keys are pressed.
  • Page 7 5.1 Display Programming hold Program than Reset Keys press Program key to HoLd show software issue for 5 secs to enter program mode ACCUM RATE PROGRAM ProG TOTAL AccESSED ENTER if PIN protected press Prog. Key * * * * to step through RESET PROG...
  • Page 8 4. PROGRAM PARAMETERS 4.1 PIN No. Program Protection Any user defined PIN number other than 0000 will engage the program protection feature, failure to input the correct PIN number will deny the ability to change any of the program parameters, but will allow the user to step through and view the existing program parameters.
  • Page 9 4.7.2 Scalable Pulse Output Pulse scaling (terminal 15) is set as the number of litres/gallons etc. per output pulse E.g. 0.1 litres/pulse, 10 litres/pulse, 100 gallons/ pulse. Range is 0.1-9999.9 Eng.unit/pulse. 4.8 Display Priority The large digits at the top of the display can be programmed to show either flow rate or resettable total. When flow rate is selected at the top display, the rate key can be used to cycle between rate, reset total and accumulate total, in this mode the instrument will default from rate to reset and accumulative totals after 1 minute, external power must be applied if required to display rate at top display continuously.
  • Page 10 1.1 Operating Principle Oval Gear flowmeters are positive displacement devices where the passage of liquid causes two oval geared rotors to rotate within a precision measuring chamber. Each rotation of the Oval rotors will transmit 4 identical volumes of liquid from the meter inlet to outlet (as shown in the diagram below);...
  • Page 11 STS-EZ-METER System Operation (Once ready to start adding inputs, make sure the STS INDUCTOR System is in proper operating mode. See STS INDUCTOR MANUAL for proper operation). Reset digital display to zero by depressing the RESET button holding for 2 sec. Identify the input and slowly open the valve.
  • Page 12 Breakdown - STS-EZ-METER 4-Product (5283077) See Detail A The STS-EZ-METER System Display Height Detail A The STS-EZ-METER System display and control panel can be adjusted to different heights to best meet the operators Typical Setup needs to observe the display and operate the control valves.
  • Page 13 Breakdown - STS-EZ-METER 6-Product (5283078) See Detail A The STS-EZ-METER System Display Height Detail A The STS-EZ-METER System display and control panel can be adjusted to different heights to best meet the operators Typical Setup needs to observe the display and operate the control valves.
  • Page 14: Warranty

    WHAT REMEDIES ARE AVAILABLE UNDER THIS LIMITED WARRANTY. If the conditions set forth above are fulfilled and the Equipment or any part thereof is found to be defective, Ag Spray Equipment shall, at its own cost, and at its option, either repair or replace the defective Equipment or part.

This manual is also suitable for:

Sts-ez-meter 5283078