ADF Web HD67G10-B2 User Manual

Modbus tcp master / http/rest server - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
Modbus TCP Master / HTTP/REST Server -
Converter
(Order Code: HD67G10-B2, HD67G10-G43-B2, HD67G10-G43-E-B2,
HD67G10-G43-VPN-B2, HD67G10-G43-E-VPN-B2)
For Website information:
www.adfweb.com?Product=HD67G10-B2
www.adfweb.com?Product=HD67G10-G43-B2
www.adfweb.com?Product=HD67G10-G43-E-B2
www.adfweb.com?Product=HD67G10-G43-VPN-B2
www.adfweb.com?Product=HD67G10-G43-E-VPN-B2
For Price information:
www.adfweb.com?Price=HD67G10-B2
Benefits and Main Features:
Power Supply 18...35V DC and 8...24 V AC
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual Modbus TCP Master / HTTP/REST Server
Document code: MN67G10_ENG
For others HTTP/REST products, see also the following links:
Converter HTTP/REST Server to
www.adfweb.com?Product=HD67G04
www.adfweb.com?Product=HD67G06
www.adfweb.com?Product=HD67G08
www.adfweb.com?Product=HD67G12
www.adfweb.com?Product=HD67G14
www.adfweb.com?Product=HD67G16
www.adfweb.com?Product=HD67G21
www.adfweb.com?Product=HD67G23
www.adfweb.com?Product=HD67G25
www.adfweb.com?Product=HD67G27
www.adfweb.com?Product=HD67G29
www.adfweb.com?Product=HD67G31
www.adfweb.com?Product=HD67G33
www.adfweb.com?Product=HD67G35
www.adfweb.com?Product=HD67G37
www.adfweb.com?Product=HD67G39
www.adfweb.com?Product=HD67G41
www.adfweb.com?Product=HD67G43
www.adfweb.com?Product=HD67G45
www.adfweb.com?Product=HD67G47
www.adfweb.com?Product=HD67G49
www.adfweb.com?Product=HD67G51
www.adfweb.com?Product=HD67G53
www.adfweb.com?Product=HD67G55
www.adfweb.com?Product=HD67G57
www.adfweb.com?Product=HD67G59
www.adfweb.com?Product=HD67G61
www.adfweb.com?Product=HD67G63
www.adfweb.com?Product=HD67G65
www.adfweb.com?Product=HD67G67
www.adfweb.com?Product=HD67G69
Do you have an your customer protocol?
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme
Revision 1.000
Page 1 of 33
(Serial)
(Modbus Master)
(Modbus Slave)
(Modbus TCP Slave)
(BACnet Master)
(BACnet Slave)
(CAN)
(CANopen)
(DALI)
(DeviceNet Master)
(DeviceNet Slave)
(DMX)
(EtherNet/IP Master)
(EtherNet/IP Slave)
(J1939)
(KNX)
(NMEA0183)
(NMEA2000)
(PROFIBUS Master)
(PROFIBUS Slave)
(PROFINET Master)
(PROFINET Slave)
(SNMP Manager)
(SNMP Agent)
(OPC UA Client)
(OPC UA Server)
(Ethernet)
(IEC 61850 Client)
(IEC 61850 Server)
(MQTT)
(MQTT Broker)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67G10-B2 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67G10-B2

  • Page 1 Converter HTTP/REST Server to Modbus TCP Master / HTTP/REST Server - www.adfweb.com?Product=HD67G04 (Serial) www.adfweb.com?Product=HD67G06 (Modbus Master) Converter www.adfweb.com?Product=HD67G08 (Modbus Slave) www.adfweb.com?Product=HD67G12 (Modbus TCP Slave) (Order Code: HD67G10-B2, HD67G10-G43-B2, HD67G10-G43-E-B2, www.adfweb.com?Product=HD67G14 (BACnet Master) HD67G10-G43-VPN-B2, HD67G10-G43-E-VPN-B2) www.adfweb.com?Product=HD67G16 (BACnet Slave) www.adfweb.com?Product=HD67G21 (CAN) www.adfweb.com?Product=HD67G23 (CANopen) www.adfweb.com?Product=HD67G25...
  • Page 2: Updated Documentation

    User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 2 of 33 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 3 of 33 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 4 of 33 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com S.r.l.
  • Page 5: Connection Scheme

    User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 5 of 33 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67G10-B2 ADFweb.com S.r.l.
  • Page 6 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 6 of 33 Industrial Electronic Devices Figure 1b: Connection scheme for HD67G10-G43-x-xxx-B2 ADFweb.com S.r.l.
  • Page 7 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 7 of 33 Industrial Electronic Devices CHARACTERISTICS: The HD67G10-xxx-x-xxx-B2 is a Modbus TCP Master / HTTP/REST Server Converter. It allows the following characteristics: Electrical isolation between Ethernet and Power Supply; Mountable on 35mm Rail DIN;...
  • Page 8: Power Supply

    User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 8 of 33 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin...
  • Page 9 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 9 of 33 Industrial Electronic Devices LEDS: The device has got four LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Recovery Mode 1: Device State (green)
  • Page 10 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 10 of 33 Industrial Electronic Devices ETHERNET: The Ethernet port is used for programming the device, for HTTP/REST communication and for Modbus TCP communication. The Ethernet connection must be made using Connector2 of HD67G10-xxx-x-xxx-B2 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 11: Recovery Button

    User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 11 of 33 Industrial Electronic Devices RECOVERY BUTTON: In order to recover the device in case of wrong firmware updating or any error that compromises correct functioning of the device, it is necessary to press the BTN1.
  • Page 12 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 12 of 33 Industrial Electronic Devices USE OF ADFWEB DISCOVERY TOOL SOFTWARE: To discover the device into the network and see its IP Address, use the available software that runs with Windows called “ADFweb Discovery Tool”.
  • Page 13 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 13 of 33 Industrial Electronic Devices USE OF COMPOSITOR SW67G10: To configure the Converter, use the available software that runs with Windows called SW67G10. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 14: New Configuration / Open Configuration

    User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 14 of 33 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a Programmable “Modbus TCP Master / HTTP/REST Server - Converter”...
  • Page 15: Software Options

    User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 15 of 33 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 16 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 16 of 33 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 17: Set Communication

    This window is divided in two sections, one for configuring the HTTP/REST network and the other for the Modbus TCP network. HTTP/REST section HTTP  S ELECT RODUCT This section is used to select the product in use. It is possible to have: HD67G10-B2; HD67G10-G43-B2; HD67G10-G43-E-B2; HD67G10-G43-VPN-B2; HD67G10-G43-E-VPN-B2. HTTP  E THERNET NTERFACES This section is used to define the general parameters of Ethernet.
  • Page 18 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 18 of 33 Industrial Electronic Devices In the field “IP Address”, the IP address of the converter is defined; In the field “SubNet Mask” the Subnet Mask of the converter is defined; In the field “Gateway”...
  • Page 19 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 19 of 33 Industrial Electronic Devices Modbus TCP Master section TCP M  E ODBUS ASTER THERNET ONNECTION This section is used to define the general parameters of Ethernet. The means of the fields are: In the field “Device Name...
  • Page 20 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 20 of 33 Industrial Electronic Devices SET HTTP/REST: By Pressing the “Set HTTP/REST” button from the main window for SW67G10 (Fig. 2) the window “Set HTTP/REST Access” appears (Fig. This section is used to define the list of the HTTP endpoints accessible by the Clients using GET and POST requests.
  • Page 21: Modbus Set Access

    User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 21 of 33 Industrial Electronic Devices MODBUS SET ACCESS: By pressing the “Modbus Set Access” button from the main window for SW67G10 (Fig. 2) the window “Set Modbus TCP Master Access” appears.
  • Page 22 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 22 of 33 Industrial Electronic Devices In the field “Max Error” the number of consecutive errors that the converter waits before suspending the request until the next reboot is defined.
  • Page 23 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 23 of 33 Industrial Electronic Devices In the field “NPoint” the number of consecutive registers to be written is defined; In the field “Poll Time” the delay time to make the request is defined; If the field “On Change”...
  • Page 24: Update Device

    User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 24 of 33 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 25 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 25 of 33 Industrial Electronic Devices Warning: If the update fails, try these points before seeking assistance: Try to repeat the operations for the updating; Try with another PC; Try to restart the PC;...
  • Page 26 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 26 of 33 Industrial Electronic Devices TEMPLATE STRING: DEFINITION OF HTTP/REST PAYLOAD It is possible to define which is the Modbus data to map inside the HTTP/REST endpoints using specific keywords. In order to link the data into the HTTP/REST endpoint, you can use these keywords: Starting bit of the Format of the...
  • Page 27 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 27 of 33 Industrial Electronic Devices Example: We have two variables mapped respectively into Position 0 and 4. The first one is an signed integer value of 16 bit, the second one is a floating point.
  • Page 28: Mechanical Dimensions

    User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 28 of 33 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 7a: Mechanical dimensions scheme for HD67G10-B2 ADFweb.com S.r.l.
  • Page 29 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 29 of 33 Industrial Electronic Devices Figure 7b: Mechanical dimensions scheme for HD67G10-G43-x-xxx-B2 ADFweb.com S.r.l.
  • Page 30: Ordering Informations

    G43: LTE module present with SIM card slot Device Family HD67G10: Modbus TCP Master / HTTP/REST Server - Converter Order Code: HD67G10-B2 Modbus TCP Master / HTTP/REST Server – Converter Order Code: HD67G10-G43-B2 Modbus TCP Master / HTTP/REST Server – Converter (LAN + SIM LTE) Order Code: HD67G10-G43-E-B2 Modbus TCP Master / HTTP/REST Server –...
  • Page 31 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 31 of 33 Industrial Electronic Devices ACCESSORIES: Order Code: AC34011 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC Order Code: AC34012 35mm Rail DIN - Power Supply 220/240V AC 50/60Hz –...
  • Page 32 User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 32 of 33 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 33: Warranties And Technical Support

    User Manual Modbus TCP Master / HTTP/REST Server Document code: MN67G10_ENG Revision 1.000 Page 33 of 33 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents