ADF Web IEC 61850 User Manual

Server / modbus master
Hide thumbs Also See for IEC 61850:

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
IEC 61850 Server / Modbus Master - Converter
(Order Code: HD67733-2-A1 , HD67733-4-A1, HD67733-5-A1)
For Website information:
www.adfweb.com?Product=HD67733
For Price information:
www.adfweb.com?Price=HD67733-2-A1
www.adfweb.com?Price=HD67733-4-A1
www.adfweb.com?Price=HD67733-5-A1
Benefits and Main Features:
Very easy to configure
Triple Electrical isolation
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual IEC 61850 Server / Modbus Master
Document code: MN67733_ENG
For other IEC 61850 products see also the following link:
Converter IEC 61850 Server to
www.adfweb.com?Product=HD67734
www.adfweb.com?Product=HD67735
www.adfweb.com?Product=HD67736
Do you have your customer protocol? Then go to:
www.adfweb.com?Product=HD67003
Do you need to choose a device? Do you want help?
www.adfweb.com?Cmd=helpme
Revision 1.000
Page 1 of 30
(Modbus Slave)
(Modbus TCP Master)
(Modbus TCP Slave)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IEC 61850 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web IEC 61850

  • Page 1 Benefits and Main Features: Very easy to configure Triple Electrical isolation Temperature range: -40°C/+85°C (-40°F/+185°F) For other IEC 61850 products see also the following link: Converter IEC 61850 Server to www.adfweb.com?Product=HD67734 (Modbus Slave) www.adfweb.com?Product=HD67735 (Modbus TCP Master) www.adfweb.com?Product=HD67736...
  • Page 2: Table Of Contents

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 2 of 30 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you that INDEX you need to check that the following document is:...
  • Page 3: Security Alert

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 3 of 30 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 4 of 30 Industrial Electronic Devices EXAMPLES OF CONNECTION: ADFweb.com S.r.l.
  • Page 5: Connection Scheme

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 5 of 30 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67733-2-A1 ADFweb.com S.r.l.
  • Page 6 User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 6 of 30 Industrial Electronic Devices Figure 1b: Connection scheme for HD67733-4-A1 ADFweb.com S.r.l.
  • Page 7 User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 7 of 30 Industrial Electronic Devices Figure 1c: Connection scheme for HD67733-5-A1 ADFweb.com S.r.l.
  • Page 8: Characteristics

    Define the parameters of IEC 61850 line; Define the parameters of Modbus line; Define IEC 61850 variables that contains the data read from the Modbus slaves; Define IEC 61850 variables that contains the data to send to the Modbus slaves; Update the device. ADFweb.com S.r.l.
  • Page 9: Power Supply

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 9 of 30 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below.
  • Page 10: Function Modes

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 10 of 30 Industrial Electronic Devices FUNCTION MODES: The device has got two function modes depending on the position of the ‘Dip2 of Dip-Switch A’: The first, with ‘Dip2 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device.
  • Page 11: Leds

    Blinks slowly (~1Hz) Blinks very slowly (~0.5Hz): update in progress 3: IEC 61850 communication Blinks quickly: Boot state It blinks when a IEC 61850 request is received (green) Blinks very slowly (~0.5Hz): update in progress Blinks quickly: Boot state 4: Modbus communication...
  • Page 12: Rs232

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 12 of 30 Industrial Electronic Devices RS232: The connection from RS232 socket to a serial port (example one from a personal computer) must be made with a Null Modem cable (a serial cable where the pins 2 and 3 are crossed).
  • Page 13: Rs422

    ETHERNET: IEC 61850 connection and the updating of the converters must be made using Connector3 and/or Connector4 of the HD67733-X-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps.
  • Page 14: Use Of Compositor Sw67733

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 14 of 30 Industrial Electronic Devices USE OF COMPOSITOR SW67733: To configure the Converter, use the available software that runs with Windows called SW67733. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 15: New Configuration / Open Configuration

    Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “IEC 61850 Server / Modbus Master - Converter” in order to configure another device in the same manner, it is necessary to maintain the folder and all its contents;...
  • Page 16: Software Options

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 16 of 30 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 17 User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 17 of 30 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 18: Set Communication

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 18 of 30 Industrial Electronic Devices SET COMMUNICATION: By Pressing the “Set Communication” button from the main window for SW67733 (Fig. 2) the window “Set Communication” appears (Fig. 3).
  • Page 19 Industrial Electronic Devices IEC 61850 S ERVER This section is used to define the main parameters of IEC 61850 line. The means of the fields are: In the field “Port” the port used for IEC 61850 communication is defined; If the field “Password” the password used for accessing to IEC 61850 variables is defined.
  • Page 20 User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 20 of 30 Industrial Electronic Devices ODBUS ASTER This section is used to define the main parameters of Modbus line. The means of the fields are: In the field “Serial”...
  • Page 21: Iec 61850 Access

    By Pressing the “IEC 61850 Access” button from the main window for SW67733 (Fig. 2) the window “Set Variables Access for IEC 61850” appears (Fig. 4). This section is used to define the IEC 61850 variables from/to which take/map the data of Modbus slaves.
  • Page 22: Modbus Set Access

    This window is divided in two parts, the "Modbus Read" (Fig. 5a) and the "Modbus Write " (Fig. 5b). The "Modbus Read" part is used to read the data from the Modbus slaves and make them available on IEC 61850 side.
  • Page 23 Time” the delay time to make the request is defined; If the field “On Change” is checked, the converter sends the writing request when the data from IEC 61850 side change value; If the field “On CMD” is checked, the converter sends the writing request when the data from IEC 61850 is received;...
  • Page 24: Tls Known Certificate

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 24 of 30 Industrial Electronic Devices TLS KNOWN CERTIFICATE: Figure 6: “TLS Known Certificate” window By pressing the “TLS Known Certificate” button from the Main Window of SW67733 (Fig. 2) the “Definition the list of Known Certificates”...
  • Page 25: Update Device

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 25 of 30 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 26 User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 26 of 30 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67733 device.
  • Page 27: Mechanical Dimensions

    User Manual IEC 61850 Server / Modbus Master Document code: MN67733_ENG Revision 1.000 Page 27 of 30 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 9: Mechanical dimensions scheme for HD67733-X-A1 ADFweb.com S.r.l.
  • Page 28: Ordering Informations

    Device Family HD67733: IEC 61850 Server / Modbus Master - Converter Order Code: HD67733-2-A1 IEC 61850 Server / Modbus Master - Converter (Modbus port: RS232) Order Code: HD67733-4-A1 IEC 61850 Server / Modbus Master - Converter (Modbus port: RS422) Order Code: HD67733-5-A1...