Bryant 615PHAQ06XA3 Installation Instructions Manual
Bryant 615PHAQ06XA3 Installation Instructions Manual

Bryant 615PHAQ06XA3 Installation Instructions Manual

High wall unit single zone ductless system sizes 06k, 09k, 12k, 18k
Hide thumbs Also See for 615PHAQ06XA3:

Advertisement

Quick Links

615PHAQ
High Wall Unit Single Zone Ductless System
Sizes 06K, 09K, 12K, 18K
INSTALLATION INSTRUCTIONS
Fig. 1 — Sizes 06K - 18K
NOTE: Read the entire instruction manual before starting the
installation. Images are for illustration purposes only.
Actual models may differ slightly.
SAFETY CONSIDERATIONS........................................................2
INSTALLATION .............................................................................5
ACCESSORIES................................................................................10
MODEL NUMBERS........................................................................10
DIMENSIONS..................................................................................11
ELECTRICAL DATA......................................................................12
WIRING DIAGRAM .......................................................................12
INSTALLATION OVERVIEW.......................................................13
INSTALLATION .............................................................................16
Step 1 - Select Your Indoor Unit ......................................................16
Step 2 - Drill Wall Hole For Connecting Piping ..............................17
Step 3 - Install Refrigerant pipe and Drain Hose..............................19
Step 4 - Electrical Work Preparation ................................................22
Step 5 - Wrap Piping and Cables......................................................24
Step 6 - Mount Indoor Unit ..............................................................25
CONNECTION INSTRUCTIONS - REFRIGERANT PIPING......26
Step 1 - Cut Pipes .............................................................................26
Step 2 - Remove Burrs......................................................................27
WIRELESS REMOTE CONTROLLER INSTALLATION............30
OPTIONAL WIRED WALL-MOUNTED REMOTE CONTROL IN-
STALLATION .................................................................................30
TROUBLESHOOTING ...................................................................31
DUCTLESS START-UP CHECKLIST - Single Zone ....................34
Specifications subject to change without notice.
TABLE OF CONTENTS
PAGE

Advertisement

loading
Need help?

Need help?

Do you have a question about the 615PHAQ06XA3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bryant 615PHAQ06XA3

  • Page 1 615PHAQ High Wall Unit Single Zone Ductless System Sizes 06K, 09K, 12K, 18K INSTALLATION INSTRUCTIONS TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS............2 INSTALLATION ................5 ACCESSORIES................10 MODEL NUMBERS................10 DIMENSIONS..................11 ELECTRICAL DATA..............12 WIRING DIAGRAM ...............12 Fig. 1 — Sizes 06K - 18K INSTALLATION OVERVIEW............13 INSTALLATION ................16 NOTE: Read the entire instruction manual before starting the Step 1 - Select Your Indoor Unit ............16...
  • Page 2 615PHAQ: Installation Instructions SAFETY CONSIDERATIONS CAUTION Installing, starting up, and servicing air- conditioning equipment can be hazardous due to system pressures, electrical components, and equipment location (roofs, elevated structures, etc.). EQUIPMENT DAMAGE HAZARD Only trained, qualified installers and service mechanics should install, Failure to follow this caution may result in equipment damage or start- up, and service this equipment.
  • Page 3 615PHAQ: Installation Instructions WARNING WARNING Turn off the air conditioner and disconnect the power before PERSONAL INJURY AND PROPERTY DAMAGE HAZARD performing any installation or repairing. Failure to do so can cause electric shock. For continued performance, reliability, and safety, the only approved accessories and replacement parts are those specified by Installation must be performed by an authorized dealer or specialist.
  • Page 4 7.3ft /2.2m, and the minimum room area of operating or storage should be as specified in Table 2. Table 3 — Models Table 4 — Refrigerant Leak MODEL BRYANT Nominal 424CFM 424CFM 424CFM 611CFM 615PHAQ06XA3 Air Volume 615PHAQ09XA3 615PHAQ12XA3 615PHAQ18XA3 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
  • Page 5 615PHAQ: Installation Instructions Table 5 — Compatibility MULTIZONE HEAT PUMP OUTDOOR UNIT 37MGRAQ30EA3 37MGRAQ18CA3 37MGRAQ24DA3 37MGRAQ48FA3 37MGRAQ55FA3 INDOOR UNIT 37MGRAQ36EA3 37MGHAQ30EA3 37MGHAQ18CA3 37MGHAQ24DA3 37MGHAQ48FA3 37MGHAQ55FA3 37MGHAQ36EA3 615PHAQ06XA3 ● ● ● ● ● ● ● ● 615PHAQ09XA3 ● ● ● ● ● ●...
  • Page 6 615PHAQ: Installation Instructions 7. Do not pierce or burn. WARNING 8. Be aware that refrigerants may not contain an odor. 9. All working procedure that affects safety means shall only be carried by competent persons. FOR FLAMMABLE REFRIGERANTS 10. Appliance shall be stored in a well ventilated area where the room size Do not use means to accelerate the defrosting process or to clean, corresponds to the room area as specific for operation.
  • Page 7 615PHAQ: Installation Instructions 1. Installation (where refrigerant pipes are allowed) - that steel pipes and components shall be protected against Any person who is involved with working on or breaking into a corrosion with a rustproof coating before applying any insulation; refrigerant circuit should hold a current valid certificate from an - that precautions shall be taken to avoid excessive vibration or industry-accredited assessment authority, which authorizes their...
  • Page 8 615PHAQ: Installation Instructions 4. Checking for presence of refrigerant - that there no live electrical components and wiring are exposed while charging, The area shall be checked with an appropriate refrigerant detector - recovering or purging the system; that there is continuity of earth prior to and during work, to ensure the technician is aware of bonding.
  • Page 9 615PHAQ: Installation Instructions the final oxygen-free nitrogen charge is used, the system shall be 17. Labeling vented down to atmospheric pressure to enable work to take place. Equipment shall be labeled stating that it has been de-commissioned The outlet for the vacuum pump shall not be close to any potential and emptied of refrigerant.
  • Page 10 3/8 in ( 9.52mm) 5/8 in ( 16mm) Φ Φ Φ Φ MODEL NUMBERS Table 9 — Model Numbers RESIDENTIAL 615PHAQ06XA3 615PHAQ09XA3 615PHAQ12XA3 615PHAQ18XA3 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
  • Page 11 615PHAQ: Installation Instructions DIMENSIONS Table 10 — Dimensions SYSTEM SIZE (208/230 V) (208/230 V) (208/230 V) (208/230 V) Height (H) in (mm) 12.56(319) 12.56(319) 12.56(319) 14.57(370) Width (W) in (mm) 37.99(965) 37.99(965) 37.99(965) 44.88(1140) Depth (D) in (mm) 9.41(239) 9.41(239) 9.41(239) 10.83(275) Weight -Net...
  • Page 12 615PHAQ: Installation Instructions ELECTRICAL DATA Table 11 — Electrical Data OUTDOOR UNIT (208/230V) (208/230V) (208/230V) (208/230V) Minimum Circuit Ampacity (MCA) Maximum Overcurrent Protection Ampacity (MOPA) Voltage-Phase-Frequency 208/230-1-60 Max – Min Voltage Range 253-187 LEGEND FLA - Full Load Amps MCA - Minimum Circuit Amps MOP- Maximum Overcurrent Protection NOTE: Outdoor Units: These units can connect with: Residential, and Light Commercial units.
  • Page 13 615PHAQ: Installation Instructions INSTALLATION OVERVIEW NOTE: Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual shape shall prevail. NOTE ON ILLUSTRATIONS: Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different.
  • Page 14 615PHAQ: Installation Instructions Installation Summary - Indoor Unit Distance from ceiling is determinded by the installation method. >4.72in >4.72in (12cm) (12cm) 70.87in(1.8m) Select Installation Location Attach Mounting Plate Determine Wall Hole Position Drill Wall Hole Prepare Drain Hose Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
  • Page 15 615PHAQ: Installation Instructions Installation Summary - Indoor Unit Wrap Piping and drain hose Connect Wiring Connect Piping Mount Indoor Unit Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
  • Page 16 615PHAQ: Installation Instructions INSTALLATION Step 1 - Select Your Indoor Unit Install your Indoor Unit. Select installation location NOTE : PRIOR TO INSTALLATION Before installing the indoor unit, refer to the label on the product box to ensure that the model number of the indoor unit matches the model number of the outdoor unit.
  • Page 17 615PHAQ: Installation Instructions Step 2 - Drill Wall Hole For Connecting Piping Determine wall hole location NOTE : WALL HOLE SIZE The size of the wall hole is determined by the connecting pipes. When the pipe size of the gas side is 5/8in( 16mm) or more, the wall hole should be 3.54in( 90mm). When the pipe size of gas side is less than 5/8in( 16mm), the wall hole should be 2.5in( 65mm).
  • Page 18 615PHAQ: Installation Instructions CAUTION When drilling the wall hole, be sure to avoid wires, plumbing, and other sensitive components. Drill wall hole 2.5in 3.54in (Φ 65mm) (Φ 90mm) Step 1: Using a 2.5in(65mm) or 3.54in(90mm) core drill(according to the unit you purchased ) Using a 2.5in(65mm) or 3.54in(90mm) core drill, drill a hole in the wall.
  • Page 19 615PHAQ: Installation Instructions Step 3 - Install Refrigerant pipe and Drain Hose Prepare refrigerant piping Step 1: Based on the position of the wall hole relative to the mounting plate, choose the side from which the piping will exit the unit. You have four options for the exit direction of the piping.
  • Page 20 615PHAQ: Installation Instructions If refrigerant piping is already embedded in the wall, do the following: NOTE: UNIT IS ADJUSTABLE 1.18-1.95in 1.18-1.95in (30-50mm) Keep in mind that the hooks on the mounting plate are (30-50mm) smaller than the holes on the back of the unit. Move to left or right If you find that you don’t have ample room to connect embedded pipes to the indoor unit, the unit can be...
  • Page 21 615PHAQ: Installation Instructions Connect drain hose For the portion of the drain hose that will ● remain indoors, wrap it with foam pipe insulation to prevent condensation. Drain Remove the air filter and pour a small amount hose ● of water into the drain pan to make sure that water flows from the unit smoothly.
  • Page 22 615PHAQ: Installation Instructions Step 4 - Electrical Work Preparation WARNING BEFORE PERFORMING ANY ELECTRICAL WORK, READ THESE REGULATIONS ● BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF ● THE MAIN POWER TO THE SYSTEM. 1. All wiring must comply with local and national Connect signal and power cables electrical codes, regulations and must be installed by a licensed electrician.
  • Page 23 615PHAQ: Installation Instructions 1. Open and fix the position of the panel, then open the covers of the two lock blocks, remove the screw , then hold both sides of the lower panel in the place marked “PULL”, pull it upwards to release the buckles, then take the lower panel First open the front panel, then remove down(please refer to Page 38).
  • Page 24 615PHAQ: Installation Instructions Step 5 - Wrap Piping and Cables NOTE Before passing the piping, and drain hose through the wall hole, you must bundle them together to save space, protect them, and insulate them. Indoor Unit Step 1: Space behind Bundle the drain hose, refrigerant pipes as unit shown above.
  • Page 25 615PHAQ: Installation Instructions Step 6 - Mount Indoor Unit Hook it Connecting cable Drain hose Put pipes in wall hole Hook it and press down Check that the unit is lightly to secure firmly mounted If you installed new connective piping to the outdoor unit, do the following: If you have already passed the refrigerant piping through the hole in the wall, proceed to Step 4.
  • Page 26 615PHAQ: Installation Instructions CONNECTION INSTRUCTIONS - REFRIGERANT PIPING Step 1 - Cut Pipes When preparing refrigerant pipes, take extra care to cut and flare them properly. This will 90° ensure efficient operation and minimize the Oblique Rough Warped need for future maintenance. Measure the distance between the indoor ●...
  • Page 27 615PHAQ: Installation Instructions Step 2 - Remove Burrs CAUTION MUST CHECK OVER THE END OF THE PIPE FOR CRACKS AND EVEN FLARING. ENSURE THE PIPE IS SEALED. Remove PVC tape from ends of pipe when Step 2: Remove burrs ● ready to perform flaring work.
  • Page 28 615PHAQ: Installation Instructions Torque Requirement to Connect Pipes CAUTION WHEN CONNECTING REFRIGERANT PIPES, BE CAREFUL NOT TO USE EXCESSIVE TORQUE OR TO DEFORM THE PIPING IN ANY WAY. YOU SHOULD FIRST CONNECT THE LOW-PRESSURE PIPE, THEN THE HIGH-PRESSURE PIPE. MINIMUM BEND RADIUS ≥4in Radius (10cm)
  • Page 29 615PHAQ: Installation Instructions Connecting Piping to the Outdoor Unit NOTE This section still needs to be operated according to the TORQUE REQUIREMENTS chart on the previous page. Step 1: Unscrew the cover from the packed ● valve on the side of the outdoor unit. Unscrew the cover Valve cover...
  • Page 30 615PHAQ: Installation Instructions WIRELESS REMOTE CONTROLLER OPTIONAL WIRED WALL-MOUNTED INSTALLATION REMOTE CONTROL INSTALLATION The wired remote controller comes with the following items: • A set of installation instructions and owner's manuals • 3 M4X20 Screws to mount on the wall •...
  • Page 31 615PHAQ: Installation Instructions TROUBLESHOOTING Table 12 — Error Codes Display Malfunction and Protection Indication ODU Fan Speed Out of Control EC07 ODU EEPROM Parameter Error EC51 EC52 ODU Coil Temperature Sensor(T3) error ODU Ambient Temperature Sensor (T4) Error EC53 EC54 COMP.
  • Page 32 615PHAQ: Installation Instructions COMMON ISSUES Table 14 — Common Issues ISSUE POSSIBLE CAUSE The Unit has a 3-minute protection feature that prevents the unit from overloading. The unit can- Unit does not turn on when pressing ON/OFF. not be restarted within three minutes of being turned off. The unit may change its setting to prevent frost from forming on the unit.
  • Page 33 615PHAQ: Installation Instructions Table 15 — Common Issues PROBLEM POSSIBLE CAUSES SOLUTION Temperature setting may be higher than ambient Lower the temperature setting room temperature The heat exchanger on the indoor or outdoor unit is Use Clean function by remote control to clean the affected dirty heat exchanger The air filter is dirty...
  • Page 34 615PHAQ: Installation Instructions DUCTLESS START-UP CHECKLIST - Single Zone Installation Data Site Address:_______________________________________________________________________________________________________ City:________________________________________________________ State:___________ Zip Code:__________________ Installing Contractor:______________________________________________________ Contractor Contact #: ( ) _____-___________ Job Name:_______________________________________________________________ Start-up Date:_____________________________ Distributor:_______________________________________________________________ System Details UNITS MODEL NO. SERIAL NO. CONTROLLER OUTDOOR UNIT INDOOR UNIT A Are the outdoor unit and indoor unit compatible? YES:______ NO:______...
  • Page 35 615PHAQ: Installation Instructions Ductless Start-Up Checklist (CONT) Piping Leak Check: System held 500 psig (max. 550psi) for a minimum of 30 minutes using dry nitrogen. YES:______ NO:______ Evacuation Method: • YES:______ NO:______ Was the Triple Evacuation Method used as outlined in the installation manual? •...
  • Page 36 615PHAQ: Installation Instructions © 2024 Carrier. All rights reserved. Edition Date: 10/24 Catalog No: 615PHAQ-01SI Replaces: NEW Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

This manual is also suitable for:

615phaq09xa3615phaq12xa3615phaq18xa3615phaq