Removing the front display panel ................7 Re-assembling the Multitrend V5 ................. 8 Keypad Replacement Chapter 5: Removing the front display panel - Teletrend V5 ..........9 Removing the keypad assembly - Multitrend V5 ..........9 Fitting the new keypad assembly ................9 Re-assembling the unit ..................
Page 4
Multitrend V5 ONLY ....................21 PCB Installation Chapter 8: Removing the rear panel ..................23 Removing the front display panel of the Teletrend V5 ........24 Removing the front display panel of the Multitrend V5 ........24 Installing the Universal Card ................26 Replacing the motherboard ...................26...
Chapter 1: Introduction This manual is intended as a guide to stripping down Honeywell recorders for the purposes of replacing or installing hardware (such as Comms cards or PSU boards) or upgrading firmware (EPROMs). Honeywell recorders are designed for ease of assembly and, as such, stripping down a unit is relatively straightforward.
Page 6
4 3 -T V- 25 - 0 4 G L O Is s u e 2 01 /0 1 UK...
Chapter 2: Alarm Card Installation Removal of the rear panel (ONLY) is necessary when this operation is intended. Removing the rear panel To remove the rear panel of the recorder, loosen and remove the four No 6 • x ¾" self tap screws at each corner of the rear panel, taking care to retain the toothed washer under each screw head.
Inserting the alarm card DO NOT disconnect any wiring from the mains socket on the rear panel, gently • move the rear panel to the side of the extrusion to allow internal access. Connect one end of the cable ribbon to the socket underneath the motherboard •...
Chapter 3: Teletrend V5 Display Replacement Removing the front display panel Loosen and remove the four No 4 x ³/ " countersunk screws from the extru- • sion which holds the front surround panel and remove the front surround. Removing the front FIGURE 3.1...
Remove the mounting plate from the front surround by removing the four No 4 x ³/ • " countersunk screws. (Those marked A in 4) Teletrend V5 mounting plate FIGURE 4.1 Remove the display from the mounting plate by removing the four M3 x 6 mm •...
Chapter 4: Multitrend V5 Display Replacement Removing the front display panel Multitrend V5 FIGURE 4.1 mounting plate Loosen and remove the four No 6 x " self tapping screws (those marked • B in FIGURE 4.1 ) from the mounting plate. Loosen and remove the five No 4 x ½"...
Loosen and remove the four M3 x 8 mm pan pozi • screws which hold the display unit to the mounting plate pillars. Disconnect the white backlight power connector • from the invertor PCB. Disconnect the ribbon cable from the display unit •...
Chapter 5: Keypad Replacement Removing the front display panel - Teletrend V5 Loosen and remove the four No 4 x ³/ " countersunk screws from the extru- • sion which holds the front surround panel and remove the front surround.
Re-assembling the unit Teletrend V5 ONLY Push the keypad through the aperture on the front display unit. • Secure the front surround panel by replacing and tightening the four No 4 x ³/ " • countersunk screws on the extrusion.
Chapter 6: Expansion Card Installation Removal of BOTH front and rear panels is necessary when these operations are intended. Removing the rear panel All models To remove the rear panel of the recorder, loosen and remove the four • panpozi screws at each corner of the rear panel, taking care to retain the toothed washer under each screw head.
Removing the front display panel - Teletrend V5 Loosen and remove the four No 4 x ³/ " countersunk screws from the extrusion • which holds the front surround panel and remove the front surround. Removing the front panel FIGURE 6.2 Disconnect the cable ribbons from the keypad and display.
Page 17
Removing the front surround and the display unit from the FIGURE 6.4 mounting plate pillars on the Multitrend Plus Place the front surround face down on a soft, clean dust free surface to avoid • scratch damage. Cover the LCD and the inside of the display unit screen with protective plastic. •...
Installing the RS485 Trendbus Communications Card Slide all the PCB assembly from the extrusion, supporting the motherboard. • Trendbus The position of the Trendbus communications card FIGURE 6.6 Fit the RS485 Trendbus card in connector position J9 and J18 on the left side of •...
Installing the Modbus Communications Card Slide all the PCB assembly from the extrusion, supporting the motherboard. • Insert the RS486 (Modbus) card in connectors J9 and J18 on the left side of the • motherboard ensuring the pins are in the correctly corresponding ports. That is, the pins on the communications card match the indents on the ports, (i.e the card is placed in its sockets so that pin 1 of the card is fitted to pin 1 of the socket).
Tuck in the cable ribbon as a loose "S" shape between the motherboard and • alarm card. Teletrend V5 ONLY • Secure the front surround panel by replacing and tightening the four No 4 x ³/ " “countersunk screws on the extrusion.
Chapter 7: Upgrading Firmware Removal of BOTH front and rear panels is necessary when this operation is intended. Removing the rear panel All models To remove the rear panel of the recorder, loosen and remove the four • panpozi screws at each corner of the rear panel, taking care to retain the toothed washer under each screw head.
Page 22
Removing the front display panel - Teletrend V5 Loosen and remove the four No 4 x ³/ " countersunk screws from the extrusion which • holds the front surround panel and remove the front surround. Removing the front panel FIGURE 7.2 Disconnect the cable ribbons from the keypad and display.
Page 23
Removing the front surround and the display unit from the FIGURE 7.4 mounting plate pillars on the Multitrend Plus Place the front surround face down on a soft, clean dust free surface to avoid • scratch damage. Cover the LCD and the inside of the display unit screen with protective plastic. •...
Tuck in the cable ribbon as a loose "S" shape between the motherboard and alarm • card. Teletrend V5 ONLY • Secure the front surround panel by replacing and tightening the four No 4 x ³/ "...
Page 25
Multitrend V5 ONLY • Reconnect the power lead to the motherboard from the disk drive. • Reconnect the ribbon cable to the display unit from the motherboard. • Reconnect the invertor lead to point J20 on the motherboard. • Place the display unit on the mounting plate pillars. •...
Page 26
4 3 -T V- 25 - 0 4 G L O Is s u e 2 01 /0 1 UK...
Chapter 8: PCB Installation Removal of BOTH front and rear panels is necessary when this operation is intended. Removing the rear panel All models To remove the rear panel of the recorder, loosen and remove the four • panpozi screws at each corner of the rear panel, taking care to retain the toothed washer under each screw head.
Removing the front display panel of the Teletrend V5 Loosen and remove the four No 4 x ³/ " countersunk screws from the extrusion which • holds the front surround panel and remove the front surround. Removing the front panel FIGURE 8.2...
Page 29
Removing the front surround and the display unit from the FIGURE 8.4 mounting plate pillars on the Multitrend Plus Place the front surround face down on a soft, clean dust free surface to avoid • scratch damage. Cover the LCD and the inside of the display unit screen with protective plastic. •...
Installing the Universal Card Slide all the PCB assembly from the extrusion, supporting the motherboard. • Universal card The position of the Universal card FIGURE 8.6 If fitted, disconnect the alarm card ribbon cable from the motherboard and remove • the alarm card.
Removing the EPROMs From the Motherboard Gently remove the EPROMs with a suitable IC extractor. This is an extremely • delicate operation which may require gradual pressure and levering to remove the EPROMs. Removing EPROMs FIGURE 8.7 Replacing the motherboard Fit the EPROMs to the new motherboard ensuring that the EPROM labelled •...
Teletrend V5 ONLY • Secure the front surround panel by replacing and tightening the four No 4 x ³/ " countersunk screws on the extrusion. • Reconnect the cable ribbon to the keypad, keeping it straight and the cable rib- bon to the display, ensuring that the metal contacts are face forwards.
Page 33
Price plus a combination of factors Follow up response Prefer to deal with a reputable company Overall level of service Honeywell offers more than the competition in terms How could our service be improved upon? of ’added value’ over and above the product itself ................
Page 34
Tel. : 46 8 775 55 00 This publication does not constitute a contract between Honeywell and its customers. The contents may be changed at any time without notice. It is the cus- tomer’s responsibility to ensure safe installation and operation of the products. Detailed mounting drawings of all products illustrated are available on request.
Need help?
Do you have a question about the Teletrend V5 and is the answer not in the manual?
Questions and answers