Siemens ET 200eco PN Master Equipment Manual
Siemens ET 200eco PN Master Equipment Manual

Siemens ET 200eco PN Master Equipment Manual

Communications module
Table of Contents

Advertisement

Quick Links

SIMATIC
ET 200eco PN
CM 4x IO-Link + DIQ 12x24VDC
M12-L 8xM12
(6ES7148-6JE00-0BB0)
communications module
Equipment Manual
10/2024
A5E51718286-AD
Introduction
Industrial cybersecurity
Product overview
Wiring
PROFINET IO
EtherNet/IP
Modbus TCP
Technical specifications
Dimension drawing
Parameter data record
1
2
3
4
5
6
7
8
A
B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ET 200eco PN Master and is the answer not in the manual?

Questions and answers

Summary of Contents for Siemens ET 200eco PN Master

  • Page 1 Introduction Industrial cybersecurity SIMATIC Product overview ET 200eco PN CM 4x IO-Link + DIQ 12x24VDC Wiring M12-L 8xM12 (6ES7148-6JE00-0BB0) communications module PROFINET IO Equipment Manual EtherNet/IP Modbus TCP Technical specifications Dimension drawing Parameter data record 10/2024 A5E51718286-AD...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction............................Introduction ET 200eco PN Master..................Industry Mall........................Siemens Industry Online Support..................Guide to ET 200eco PN M12-L................... 1.4.1 Information classes ET 200eco PN M12-L................1.4.2 Basic tools........................1.4.3 S7 Port Configuration Tool (S7-PCT).................. 1.4.4 MultiFieldbus Configuration Tool (MFCT)................
  • Page 4 Table of contents EtherNet/IP............................49 Functions/parameters/address space................. 49 6.1.1 Supported EtherNet/IP functions..................6.1.2 Parameters........................50 6.1.3 Explanation of the parameters..................52 6.1.4 Update time of the I/O data....................55 6.1.5 Example address space..................... 55 Diagnostics........................57 6.2.1 Status and error displays....................57 Modbus TCP............................
  • Page 5: Introduction

    • On the part of the documentation to which particular attention should be paid. Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP).
  • Page 6: Siemens Industry Online Support

    For answers and solutions concerning automation technology. • mySupport Your personal working area in Industry Online Support for messages, support queries, and configurable documents. This information is provided by the Siemens Industry Online Support in the Internet (http://www.siemens.com/automation/service&support). Guide to ET 200eco PN M12-L 1.4.1 Information classes ET 200eco PN M12-L The documentation for the SIMATIC ET 200eco PN M12-L distributed I/O system is arranged...
  • Page 7: Device Information

    With the TIA Selection Tool , you can generate a complete order list from your product selection or product configuration. You can find the TIA Selection Tool on the Internet. (https://support.industry.siemens.com/cs/ww/en/view/109767888) CM 4x IO-Link + DIQ 12x24VDC M12-L 8xM12 (6ES7148-6JE00-0BB0) communications module Equipment Manual, 10/2024, A5E51718286-AD...
  • Page 8 You can find SIEMENS PRONETA Basic on the Internet: (https://support.industry.siemens.com/cs/ww/en/view/67460624) SIEMENS PRONETA Professional is a licensed product that offers you additional functions. It offers you simple asset management in PROFINET networks and supports operators of automation systems in automatic data collection/acquisition of the components used through various functions: •...
  • Page 9: S7 Port Configuration Tool (S7-Pct)

    1.4 Guide to ET 200eco PN M12-L SINETPLAN SINETPLAN, the Siemens Network Planner, supports you in planning automation systems and networks based on PROFINET. The tool facilitates professional and predictive dimensioning of your PROFINET installation as early as in the planning stage. In addition, SINETPLAN supports you during network optimization and helps you to exploit network resources optimally and to plan reserves.
  • Page 10: Multifieldbus Configuration Tool (Mfct)

    MultiFieldbus- and DALI-devices. In addition, the MFCT offers convenient options for mass firmware updates of ET 200 devices with MultiFieldbus- support and reading service data for many other Siemens devices. Functional scope of the MFCT • MultiFieldbus configuration:...
  • Page 11: Simatic Technical Documentation

    Online Support: Industry Online Support International https://support.industry.siemens.com/cs/ww/en/view/109742705 Watch this short video to find out where you can find the overview directly in Siemens Industry Online Support and how to use Siemens Industry Online Support on your mobile device: Quick introduction to the technical documentation of automation products per video ( https://support.industry.siemens.com/cs/us/en/view/109780491...
  • Page 12: Application Examples

    Manuals, characteristics, operating manuals, certificates • Product master data You can find "mySupport" on the Internet. (https://support.industry.siemens.com/My/ww/en) Application examples The application examples support you with various tools and examples for solving your automation tasks. Solutions are shown in interplay with multiple components in the system - separated from the focus on individual products.
  • Page 13: Industrial Cybersecurity

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to...
  • Page 14: Cybersecurity-Relevant Information

    Corrective measures for known risks Corrective measures for known risks are announced on the Siemens ProductCERT and Siemens CERT (https://siemens.com/productcert) web page. You can find more information on SIEMENS ProductCERT in the System Manual (https://support.industry.siemens. com/cs/ww/en/view/109778292). Secure decommissioning You can find information on secure decommissioning in the...
  • Page 15: Product Overview

    Product overview Properties Article number 6ES7148-6JE00-0BB0 View of the module PN /M F RN /NS (L AN ) ER /MS X1 P1 R MT /IO PW R IO -L IN K PO RT P1 LK CL AS S A X1 P2 R X1 0 P2 LK IO-L 1...
  • Page 16 Product overview 3.1 Properties Properties The module has the following technical properties: • IO-Link master according to IO-Link specification V1.1 • 4 IO-Link ports Class A • 12 digital inputs/digital outputs, depending on parameter assignment • SIO mode (standard IO mode) •...
  • Page 17: Other Components

    • M12 sealing cap See also You can find more information on the accessories in the ET 200eco PN M12-L distributed I/O system (http://support.automation.siemens.com/WW/view/en/109774008) system manual. CM 4x IO-Link + DIQ 12x24VDC M12-L 8xM12 (6ES7148-6JE00-0BB0) communications module Equipment Manual, 10/2024, A5E51718286-AD...
  • Page 18: Operator Controls And Display Elements

    Product overview 3.2 Operator controls and display elements Operator controls and display elements The following figure shows the operator controls and display elements of the CM 4x IO-Link + DIQ 12x24VDC M12-L communications module. RN/NS PN/MF (LAN) ER/MS MT/IO X1 P1R P1 LK IO-LINK PORT P2 LK CLASS A X1 P2R IO-L 1...
  • Page 19: Functions

    Product overview 3.3 Functions Functions IO-Link is a point-to-point connection between an IO-Link master and an IO-Link device. On the IO-Link master, you can use IO-Link devices as well as conventional sensors/actuators with unshielded standard cables using proven 3-wire technology. IO-Link is downward-compatible to conventional digital sensors and actuators.
  • Page 20 You configure the IO-Link master with the Port Configuration Tool S7-PCT (PDCT) V3.5 SP3 or higher. Reference For more information on the IO-Link system, please see the IO-Link system (http://support.automation.siemens.com/WW/view/en/65949252) function manual. CM 4x IO-Link + DIQ 12x24VDC M12-L 8xM12 (6ES7148-6JE00-0BB0) communications module Equipment Manual, 10/2024, A5E51718286-AD...
  • Page 21: Reset Communication Module To Factory Settings

    • SIMATIC S7-PCT Factory Reset PROFINET factory reset You can find additional information on the PROFINET factory reset in the ET 200eco PN M12-L distributed I/O system (http://support.automation.siemens.com/WW/view/en/109774008) system manual. SIMATIC S7-PCT Factory Reset You trigger the reset to the factory settings in SIMATIC S7-PCT tool.
  • Page 22: Wiring

    Wiring Terminal and block diagram The following figure shows an example of the pin assignment for port Class A. ① Bus interface with integrated 2-port switch Supply voltage 1L+ (non-switched) ② Monitoring 2L+ Ground 1M (non-switched) ③ IO-Link/DIQ circuit (1L+, 1M) Load voltage 2L+ (switched) ④...
  • Page 23: Pin Assignment

    Wiring 4.2 Pin assignment Input signal/output signal X1 P1R PROFINET Port 1 X10 to X13 IO-Link port Class A + DIQ X2 P2R PROFINET Port 2 X14 to X17 P1 LK/P2 LK LED LINK Port 1/Port 2 (green) Ground with reverse polarity protection, Ground with reverse polarity protection, derived from 1 M (non-switched) derived from 2M (switched)
  • Page 24 Wiring 4.2 Pin assignment Assignment Front view of the sockets Port Class A X10, X12 X11, X13 Ground 1M (non-switched) IO-Link port 1: Connector X10 IO-Link port 2: Connector X11 IO-Link port 3: Connector X12 IO-Link port 4: Connector X13 Not used NOTICE 24 V encoder supply 1U...
  • Page 25 Wiring 4.2 Pin assignment Assignment Front view of the sockets X14 to X17 - sockets for digital inputs/digital X14, X16 X15, X17 outputs Connector X14: Input/output signal DIQ Connector X15: Input/output signal DIQ Connector X16: Input/output signal DIQ Connector X17: Input/output signal DIQ Ground 2M Connector X14: Input/output signal DIQ Connector X15: Input/output signal DIQ...
  • Page 26 Wiring 4.2 Pin assignment Pin assignment of the socket for loop-through of the supply voltage (M12 L-coded) The table below shows the pin assignment of the M12 L-coded socket for loop-through of the supply voltage. Table 4-5  Pin assignment of the supply voltage socket Assignment of the core color Assignment Front view of the socket...
  • Page 27: Profinet Io

    PROFINET IO Parameters/address space 5.1.1 Parameters Parameters The table below shows the parameters that you can set for each port (each submodule) of the IO-Link master CM 4x IO-Link + DIQ 12x24VDC M12-L. Table 5-1  Diagnostics and port parameters, IO-Link ports Parameters Value range Default...
  • Page 28: Explanation Of The Parameters

    PROFINET IO 5.1 Parameters/address space Table 5-2  Configurable parameters and their defaults (GSD file), DIQ Parameter Value range Default Scope with con­ figuration soft­ ware, e.g. STEP 7 (TIA Portal) Diagnostics: Undervoltage 1L+ • Disable Disable Channels 0...11 • Enable Diagnostics: Missing 2L+ •...
  • Page 29: Input Delay

    PROFINET IO 5.1 Parameters/address space Hardware interrupt (device notification) Enable of the hardware interrupt for the selected IO-Link port. The possible hardware interrupts are dependent on the IO-Link device used. More information on the hardware interrupts can be found in the description of the IO-Link device used.
  • Page 30: Operating Mode

    PROFINET IO 5.1 Parameters/address space Hardware interrupt on falling edge (only for DIQ) Specifies whether a hardware interrupt is generated for a falling edge on the channel. Configuration mode (only for DIQ) Specifies whether the channel operates as digital input (DI) or digital output (DQ). Reaction to CPU STOP (only for DIQ) With this parameter, you set the reaction of the digital outputs of the I/O device after a CPU STOP:...
  • Page 31 • ET 200AL DQ 8x24VDC/2A 8xM12 (6ES7142-5AF00-0BL0) See also You can find out more about the vendor ID and the device ID of an IO-Link device on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109748852). CM 4x IO-Link + DIQ 12x24VDC M12-L 8xM12 (6ES7148-6JE00-0BB0) communications module Equipment Manual, 10/2024, A5E51718286-AD...
  • Page 32: Address Space

    PROFINET IO 5.1 Parameters/address space 5.1.3 Address space Introduction The IO-Link master CM 4x IO-Link + DIQ 12x24VDC M12-L has four ports. Each port is represented by a submodule. The IO-Link master and DIQ slot have separate process data areas: •...
  • Page 33 PROFINET IO 5.1 Parameters/address space Port Qualifier Information (PQI) NOTE Port Qualifier Information (PQI) The Port Qualifier Information (PQI) with the size 1 byte is always transmitted together with the input data of the IO-Link device. The PQI cannot be deactivated. Name Value Meaning...
  • Page 34 PROFINET IO 5.1 Parameters/address space Address space for configuration as 1 x 12-channel DIQ 12x24VDC The following figure shows the address space allocation with configuration as 12-channel I/O device with digital inputs/digital outputs without value status. The addresses of the channels are derived from the start address.
  • Page 35 PROFINET IO 5.1 Parameters/address space Address space for configuration as 1 x 12-channel DIQ 12x24VDC QI The following figure shows the address space allocation with configuration as 12-channel I/O device with digital inputs/digital outputs with value status. The addresses of the channels are derived from the start address.
  • Page 36 PROFINET IO 5.1 Parameters/address space Address space for configuration as 1 x 12-channel DIQ 12x24VDC MSI/MSO The 1st submodule (= basic submodule) behaves like a 1 x 12-channel DIQ 12x24VDC. The value status (Quality Information, QI) is always activated for the submodule. Diagnostics and hardware interrupts are signaled for this submodule.
  • Page 37 PROFINET IO 5.1 Parameters/address space The following figure shows the assignment of the address space with submodules 1 and 2 and the value status. Figure 5-4  Address space for configuration as 1 x 12-channel DIQ 12x24VDC MSI/MSO with value status (basic submodule) CM 4x IO-Link + DIQ 12x24VDC M12-L 8xM12 (6ES7148-6JE00-0BB0) communications module Equipment Manual, 10/2024, A5E51718286-AD...
  • Page 38 Figure 5-5  Address space for configuration as 1 x 12-channel DIQ 12x24VDC MSI/MSO with value status (MSI/MSO submodule) Reference For more information, please refer to the IO-Link system (http://support.automation.siemens.com/WW/view/en/65949252) function manual. CM 4x IO-Link + DIQ 12x24VDC M12-L 8xM12 (6ES7148-6JE00-0BB0) communications module Equipment Manual, 10/2024, A5E51718286-AD...
  • Page 39: Interrupts/Diagnostics Alarms

    PROFINET IO 5.2 Interrupts/diagnostics alarms Interrupts/diagnostics alarms 5.2.1 Status and error displays LED displays The following figure shows the LED display of the CM 4x IO-Link + DIQ 12x24VDC M12-L 8xM12 communications module. RN/NS PN/MF (LAN) ER/MS MT/IO X1 P1R P1 LK IO-LINK PORT P2 LK...
  • Page 40: Meaning Of The Leds

    PROFINET IO 5.2 Interrupts/diagnostics alarms Meaning of the LEDs The following tables set out the meaning of the status and error displays. Behavior of the Run, Error and Maintenance LEDs Table 5-3  Error display of the LED Meaning Remedy RN/NS ERR/MS MT/IO (yel­...
  • Page 41 PROFINET IO 5.2 Interrupts/diagnostics alarms Meaning Remedy RN/NS ERR/MS MT/IO (yel­ (green) (red) low) Not relevant Not relevant Maintenance Evaluate the maintenance On (yellow) events. The "Node flash test" is running (the P1 LK and P2 LK LEDs of flashes flashes flash the PROFINET interface also flash).
  • Page 42: Interrupts

    PROFINET IO 5.2 Interrupts/diagnostics alarms Channel status LEDs DIQ Table 5-6  Status displays of the DIQ LEDs LEDs Meaning Channel status/channel error Process value = 0 Process value = 1 On (green) Channel error On (red) Channel status/channel error LEDs IO-Link LEDs Meaning Channel status/error...
  • Page 43: Hardware Interrupts

    PROFINET IO 5.2 Interrupts/diagnostics alarms Diagnostics interrupts All IO-Link events of the type Error or Warning are mapped to the diagnostic interrupts of the assigned submodule. If you have parameterized the IO-Link master accordingly, it triggers a diagnostic interrupt for an incoming or outgoing event (alarm). The coding of the events corresponds to the PROFINET standard of the extended channel diagnostics (USI=0x8002).
  • Page 44: Diagnostics Alarms

    PROFINET IO 5.2 Interrupts/diagnostics alarms 5.2.3.1 Diagnostics alarms IO-Link master error types All IO-Link events of the type Error generated by the IO-Link device or port are mapped to the PROFINET diagnostics alarm of the type (severity) "Diagnosis" of the assigned submodule. IO-Link device diagnostics The IO-Link master generates PROFINET channel diagnostics (CET, ECET) from the IO-Link events of an IO-Link device according to the following mapping regulations:...
  • Page 45 PROFINET IO 5.2 Interrupts/diagnostics alarms Error type Extended error Error text Meaning (CET) type (ECET) 0x9502 0x1803 Wrong device DeviceID Check device (38136 (6147 0x1804 Short-circuit to C/Q Check port connection (6148 0x1805 IO-Link PHY overtem­ (6149 perature 0x1806 Short-circuit to L+ Check port connection (6150 0x1808...
  • Page 46: Maintenance Events

    Replace the defective Short-circuit to ground encoder/actuator. See also Diagnostics function manual (https://support.industry.siemens.com/cs/ww/en/view/59192926) 5.2.3.2 Maintenance events Maintenance events for IO-Link master All IO-Link events of the type Warning generated by the IO-Link device or port are mapped to the PROFINET diagnostics alarm of the type "Maintenance" of the assigned submodule. The aim is the early detection and elimination of potential faults.
  • Page 47 PROFINET IO 5.2 Interrupts/diagnostics alarms Maintenance events for DIQ and for IO-Link master The MultiFieldbus interfaces of the ET 200eco PN M12-L support the diagnostics concept and maintenance concept in PROFINET according to the IEC 61158-6-10 standard. The goal is to detect and remove potential problems as early as possible.
  • Page 48: Process Alarm Events

    PROFINET IO 5.2 Interrupts/diagnostics alarms 5.2.3.3 Process alarm events Hardware interrupt events for IO-Link master All IO-Link events (event codes) of the Notification type that are generated by the IO-Link device are mapped to the PROFINET process alarm of the assigned submodule. The additional alarm information read out using RALRM contains the relevant IO-Link event code.
  • Page 49: Ethernet/Ip

    EtherNet/IP Functions/parameters/address space 6.1.1 Supported EtherNet/IP functions Supported functions The table below shows the functions that the I/O device supports with EtherNet/IP. Supported functions Remarks I/O communication with scanner FW 5.1.x or higher Parameter assignment FW 5.1.x or higher Reading diagnostics FW 5.1.x or higher Normative CIP objects FW 5.1.x or higher...
  • Page 50: Parameters

    EtherNet/IP 6.1 Functions/parameters/address space Supported CIP objects for EtherNet/IP The table below shows the CIP objects that the I/O device supports with EtherNet/IP. Supported CIP objects Remarks Identity object FW 5.1.x or higher Assembly object FW 5.1.x or higher Connection Manager object FW 5.1.x or higher TCP/IP Interface object FW 5.1.x or higher...
  • Page 51 EtherNet/IP 6.1 Functions/parameters/address space Parameter Value range Default Scope with configura­ tion software, for example, MFCT DeviceID* Device ID of the con­ Channel nected IO-Link device Inspection Level/Data Storage* • Same type (V1.0) Type-compatible Channel without (V1.1) with Backup&Restore Backup&Restore •...
  • Page 52: Explanation Of The Parameters

    EtherNet/IP 6.1 Functions/parameters/address space 6.1.3 Explanation of the parameters Diagnostics: Undervoltage 1L+ Enabling of the diagnostics for insufficient supply voltage 1L+. Diagnostics port This parameter enables the diagnostics for the selected IO-Link port. In the diagnostics A distinction is made between error and maintenance interrupts. The possible diagnostics are dependent on the IO-Link device used.
  • Page 53: Input Delay

    EtherNet/IP 6.1 Functions/parameters/address space Input delay This parameter can be used to suppress signal interference. Changes to the signal are only detected if they are present consistently for longer than the set input delay time. For input channels with longer input delays, the read-in time is moved accordingly. This means individual channels can be assigned input delays, if necessary, without having a negative impact on the possible cycle time.
  • Page 54: Operating Mode

    • ET 200AL DQ 8x24VDC/2A 8xM12 (6ES7142-5AF00-0BL0) See also You can find out more about the vendor ID and the device ID of an IO-Link device on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109748852). CM 4x IO-Link + DIQ 12x24VDC M12-L 8xM12 (6ES7148-6JE00-0BB0) communications module Equipment Manual, 10/2024, A5E51718286-AD...
  • Page 55: Update Time Of The I/O Data

    EtherNet/IP 6.1 Functions/parameters/address space 6.1.4 Update time of the I/O data You can estimate the typical update time for an I/O cycle as follows:     RPI timer (settable from 2 to 20 ms ± 10 %) default 10 ms     + I/O processing (typically 1.4 ms, ± 1 ms jitter due to free-running cycles)     + EM conversion (dependent on cycle time and parameter assignment of the module) If necessary, you must take into account other influences caused by the EIP scanner and network components by adding them.
  • Page 56: Input Range

    IO-Link 1 I/ 1 O + PQI Outputs DIQ 12x24VDC/0.5A/2A Outputs DIQ 12x24VDC/0.5A/2A See also You can find more information in the MultiFieldbus (https://support.industry.siemens.com/cs/ww/en/view/109773209) function manual. CM 4x IO-Link + DIQ 12x24VDC M12-L 8xM12 (6ES7148-6JE00-0BB0) communications module Equipment Manual, 10/2024, A5E51718286-AD...
  • Page 57: Diagnostics

    EtherNet/IP 6.2 Diagnostics Diagnostics 6.2.1 Status and error displays LED displays The figure below shows the LED displays (status and error displays) of the I/O device CM 4x IO-Link + DIQ 12x24VDC M12-L RN/NS PN/MF (LAN) ER/MS MT/IO X1 P1R P1 LK IO-LINK PORT P2 LK...
  • Page 58 EtherNet/IP 6.2 Diagnostics Behavior of the RN/NS (RUN/network status), ER/MS (ERROR/module status) and MT/IO (MAINT/IO status) LEDs The LEDs display the status with the highest priority if there are different LED states due to overlaid events. (0 = off, 1 = green flashing, 2 = green, 3 = yellow, 4 = red flashing, 5 = red) The tables below show the meaning of the RN/NS, ER/MS and MT/IO LEDs: Table 6-3  Error display of the LEDs LEDs...
  • Page 59 EtherNet/IP 6.2 Diagnostics LEDs Meaning Remedy Test of LEDs during startup: The three LEDs light up simultaneously for Flashes Flashes Flashes approximately 0.25 s in red, then for approximately 0.25 s in green. Hardware or firmware defective. • You can read out the service data with STEP 7 V5.6.
  • Page 60: Modbus Tcp

    Modbus TCP Functions/parameters/address space 7.1.1 Supported Modbus TCP functions Supported functions The table below shows the functions that the I/O device supports with Modbus TCP. Supported functions RegLayoutVersion Remarks I/O communication with Modbus client V1.0 FW 5.1.x or higher Free user registers (e.g. for coordination of the redundancy) V1.0 FW 5.1.x or higher Device information...
  • Page 61: Parameters

    Modbus TCP 7.1 Functions/parameters/address space 7.1.2 Parameters Parameters The table below shows the parameters that you can set for each port (each submodule) of the IO-Link master CM 4xIO-Link + DIQ 12x24VDC M12-L. Table 7-1  Diagnostics and port parameters Parameter Value range Default Scope with configura­...
  • Page 62: Explanation Of The Parameters

    Modbus TCP 7.1 Functions/parameters/address space Table 7-2  Configurable parameters and their defaults (GSD file), DIQ Parameter Value range Default Scope with con­ figuration soft­ ware, for example, MFCT Diagnostics: Undervoltage 1L+ • Disable Disable Channels 0...11 • Enable Diagnostics: Missing 2L+ •...
  • Page 63 Modbus TCP 7.1 Functions/parameters/address space Hardware interrupt (device notification) Enable of the hardware interrupt for the selected IO-Link port. The possible hardware interrupts are dependent on the IO-Link device used. More information on the hardware interrupts can be found in the description of the IO-Link device used.
  • Page 64 Modbus TCP 7.1 Functions/parameters/address space Hardware interrupt on falling edge (only for DIQ) Specifies whether a hardware interrupt is generated for a falling edge on the channel. Configuration mode (only for DIQ) Specifies whether the channel operates as digital input (DI) or digital output (DQ). Reaction to CPU STOP (only for DIQ) With this parameter, you set the reaction of the digital outputs of the I/O device after a CPU STOP:...
  • Page 65: Update Time Of The I/O Data

    • ET 200AL DQ 8x24VDC/2A 8xM12 (6ES7142-5AF00-0BL0) See also You can find out more about the vendor ID and the device ID of an IO-Link device on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109748852). 7.1.4 Update time of the I/O data You can estimate the typical update time for an I/O cycle as follows:    ...
  • Page 66: Example Address Space

    Modbus TCP 7.1 Functions/parameters/address space 7.1.5 Example address space Example configuration The following figure shows the configuration for this example in MFCT: Figure 7-1  MFCT IO-Link master Input range The table below shows the input range for the example configuration: Slot Subslot DataItem Description...
  • Page 67 IO-Link 1 I/ 1 O + PQI Outputs DIQ 12x24VDC/0.5A/2A Outputs DIQ 12x24VDC/0.5A/2A See also You can find more information in the MultiFieldbus (https://support.industry.siemens.com/cs/ww/en/view/109773209) function manual. CM 4x IO-Link + DIQ 12x24VDC M12-L 8xM12 (6ES7148-6JE00-0BB0) communications module Equipment Manual, 10/2024, A5E51718286-AD...
  • Page 68: Diagnostics

    Modbus TCP 7.2 Diagnostics Diagnostics 7.2.1 Status and error displays CM 4x IO-Link + DIQ 12x24VDC M12-L 8xM12 (6ES7148-6JE00-0BB0) communications module Equipment Manual, 10/2024, A5E51718286-AD...
  • Page 69 Modbus TCP 7.2 Diagnostics Principle LED displays The figure below shows the LED displays (status and error displays) of the I/O device CM 4x IO-Link + DIQ 12x24VDC M12-L RN/NS PN/MF (LAN) ER/MS MT/IO X1 P1R P1 LK IO-LINK PORT P2 LK CLASS A X1 P2R...
  • Page 70 Modbus TCP 7.2 Diagnostics Behavior of the RN/NS (RUN/network status), ER/MS (ERROR/module status) and MT/IO (MAINT/IO status) LEDs The LEDs display the status with the highest priority if there are different LED states due to overlaid events. (0 = off, 1 = green flashing, 2 = green, 3 = yellow, 4 = red flashing, 5 = red) The tables below show the meaning of the RN/NS, ER/MS and MT/IO LEDs: Table 7-3  Error display of the LEDs LEDs...
  • Page 71 Modbus TCP 7.2 Diagnostics PWR LED Table 7-4  Status display of the PWR LED PWR LED Meaning Load voltage 2L+ is missing or too low Load voltage 2L+ present P1 LK and P2 LK LEDs Table 7-5  Error display of the P1 LK and P2 LK LEDs LEDs Meaning Solution...
  • Page 72: Technical Specifications

    Technical specifications of the CM 4xIO-Link + DIQ 12x24VDC M12-L communications module The following table shows the technical specifications as of the issue date. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/de/en/pv/6ES7148-6JE00-0BB0/td?dl=de). Article number 6ES7148-6JE00-0BB0 General information  ...
  • Page 73 Technical specifications Article number 6ES7148-6JE00-0BB0 Load voltage 1L+   • Rated value (DC) 24 V permissible range, lower limit (DC) 20.4 V • • permissible range, upper limit (DC) 28.8 V • Reverse polarity protection Yes; Against destruction; encoder power supply outputs applied with reversed polarity Load voltage 2L+  ...
  • Page 74 Technical specifications Article number 6ES7148-6JE00-0BB0 Input voltage   • Rated value (DC) 24 V for signal "0" -3 to +5V • • for signal "1" +11 to +30V Input current   • for signal "1", typ. 2.5 mA Input delay (for rated value of input  ...
  • Page 75 Technical specifications Article number 6ES7148-6JE00-0BB0 Switching frequency   • with resistive load, max. 0.5 A: 100 Hz / 2 A: 40 Hz with inductive load, max. 0.5 Hz • • on lamp load, max. 1 Hz Total current of the outputs   •...
  • Page 76 Technical specifications Article number 6ES7148-6JE00-0BB0 1. Interface   Interface type PROFINET with 100 Mbit/s full duplex (100BASE-TX) Interface types   • M12 port Yes; 2x M12, 4-pin, D-coded • Number of ports • integrated switch Protocols   • PROFINET IO Device •...
  • Page 77 Technical specifications Article number 6ES7148-6JE00-0BB0 EtherNet/IP   Services   – CIP Implicit Messaging CIP Explicit Messaging – – CIP Safety – Shared device Yes; 2x EtherNet/IP Scanner – Number of scanners with shared device, max. Updating times   – Requested Packet Interval (RPI) 2 ms Redundancy mode  ...
  • Page 78 Technical specifications Article number 6ES7148-6JE00-0BB0 Alarms   • Diagnostic alarm Yes; Parameterizable Maintenance interrupt Yes; Parameterizable • • Hardware interrupt Yes; Parameterizable Diagnoses   • Diagnostic information readable • Monitoring the supply voltage – parameterizable Wire-break Yes; DI, input current < 0.3 mA, per channel •...
  • Page 79 Cat. 3 SIL acc. to IEC 62061 SIL 2 • • remark on safety-oriented shutdown https://sup­ port.industry.siemens.com/cs/de/en/view/39198­ Use in hazardous areas   • Explosion protection category for gas ATEX, UKEX, IECEx, CCCEx for Zone 2 • Explosion protection category for dust...
  • Page 80 Technical specifications Power reduction (derating) to total current of outputs, per module, The following derating curves show the load capacity of the transducer supply outputs in relation to the mounting position and the ambient temperature. ① Total current of the outputs X10 to X13 (1L+) ②...
  • Page 81: Dimension Drawing

    Dimension drawing The following figure shows the dimension drawing of the CM 4xIO-Link + DIQ 12x24VDC M12-L communications module in front and side view. RN/NS PN/MF (LAN) ER/MS MT/IO X1 P1R P1 LK IO-LINK PORT CLASS A P2 LK X1 P2R IO-L 1 IO-LINK PORT CLASS A DIQ 0 IO-L 2...
  • Page 82: Parameter Data Record

    Parameter data record Dependencies for the configuration The parameter settings are dependent on each other when configuring the I/O device. These dependencies must be considered when configuring with the latest HSP in STEP 7 TIA. When configuring with the GSD file or with data record 128, these dependencies must be observed. Dependencies of the parameter settings This table lists the parameters and their dependencies.
  • Page 83: Structure Of Data Record 128 For I/O Device Parameter Assignment (Diq)

    Parameter data record B.2 Structure of data record 128 for I/O device parameter assignment (DIQ) Structure of data record 128 for I/O device parameter assignment (DIQ) With data record 128, you can reconfigure the I/O device in your user program, regardless of your programming.
  • Page 84 Parameter data record B.2 Structure of data record 128 for I/O device parameter assignment (DIQ) Bit → Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte ↓ Device parameter block Reserved 5...6 Channel header information Number of channel parameter blocks Parameter assignment as a 1 x 12-channel I/O device = 12...
  • Page 85: Error Transferring The Data Record

    Parameter data record B.3 Error transferring the data record Bit → Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte ↓ 34…36 Channel 9 channel parameter block 37…39 *Channel 10 channel parameter block 40…42 Channel 11 channel parameter block Reserved bits must be set to 0 Valid with channel mode DI...
  • Page 86 Parameter data record B.3 Error transferring the data record Error code in STATUS parameter Meaning Solution DS128 (hexadecimal) Byte 0 Byte 1 Byte 2 Byte 3 Invalid coding for substitute value Check the parameters of the I/O ✓ reaction. device. Invalid coding for replacement filter Check the parameters of the I/O ✓...

This manual is also suitable for: