V-900 Reusable Half Face TPE/Silicon Mask & V-7900 Dual Filters
Main Features
· Venus V- 900 Series of reusable Respirators have set a new standard in comfort by having low breathing
resistance.
· The respirator is easy to handle, durable and can be easily cleaned.
· the exhalation valve helps to minimize heat built-up in the mask and increases your comfort.
· Available in three sizes, all respirators have Venus's unique Twist and Click connection system allowing
connection to a broad range of V-7900 dual lightweight filters to protect against gases, vapours and particulates
depending on your individual needs.
The Main Features include:
·
Durable, reusable, low maintenance half face respirator.
·
Soft, lightweight thermoplastic elastomeric & Silicone material reduces pressure / tension on face for
added comfort during long periods of work.
·
Transparent Staycool butterfly exhalation valve ensures easier breathing while reducing heat and
moisture build up for enhanced comfort.
·
Dual filters design provides lower breathing resistance, a more ergonomic balance fit and improves field
of vision. Provides more peripheral view, does not hinder while working and makes the use more
convenient.
·
Easy fitting with drop down feature for added convenience. No need to remove other PPE when lowering
or removing half mask. Easy to put on & remove while in use.
·
Twist and Click technology system provides effortless fitting of filters.
·
4 point unique adjustable harness design helps reduce tension & pressure points on face for good fitting
& comfort
·
Box for efficient storage of respirators and filters.
Applications
V-900 series of respirators can be used with a variety of filter options
Gas & Vapour Filters only: The filter generally protects against either single or multiple contaminant type(s).
·
V-7900 series comes with unique Twist & Click technology which fit directly onto the respirator.
Particulate Filters only: These filters provide protection against solid & non-volatile liquid particles
·
V-7900 FHP P3 filters are Particulate HEPA filters that can be used along with V-900 masks.
·
V-7900 FPD P2 filter can be attached to an adaptor and can be used with V-900 masks
Combination of Gas & Vapour Particulate filters:
·
V-7900 A2 E1 filter and V-7900 ABEK1 filters can be used with replaceable V-7900 FDP P2 pre filter
attachment.

Advertisement

loading
Need help?

Need help?

Do you have a question about the V-900 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Venus V-900 Series

  • Page 1 V-900 Reusable Half Face TPE/Silicon Mask & V-7900 Dual Filters Main Features · Venus V- 900 Series of reusable Respirators have set a new standard in comfort by having low breathing resistance. · The respirator is easy to handle, durable and can be easily cleaned.
  • Page 2 · V-7900 ABEK1 P3 has an integrated P3 particulate filter. · V-7900 A2 E1 & V-7900 ABEK1 can be used along with V-7900 FHP P3 HEPA filter by using an adaptor. Approvals These respirators have been produced to comply with the requirement of the Indian standard Institute IS 14746:1999 under an agreed production certification scheme operated during manufacture in accordance with the Bureau of Indian Standards.
  • Page 3 V-7900 range of filters Block 4...
  • Page 4 14. Always replace both filters together. 15. Venus V-900 Half mask is suitable for V-7900 Gas filter(s) & combined filter(s) 16. Refer IS 9623:2008 Selection, use and maintenance of respiratory protective devices - Code of practice -...
  • Page 5 Test for leak before (either) Negative pressure test: Seal both respiratory filters with your hands and breathe in until a negative pressure is created. Hold your breath for a moment. The negative pressure should be maintained. If not, adjust the straps or use a different size of mask.
  • Page 6: Maintenance And Storage

    Leak test:excess and/or ⃝ negative pressure Inspect For half masks in hermetically sealed packs. Otherwise every 6 months. Every 2 years in the case of half masks in hermetically sealed packs. USAGE LIFE: The duration of filter depends on concentration of contaminant and other factors. The presence of odour, taste and irritation indicates that the gas filter no longer works.
  • Page 7 Filters used against detrimental gases that do not display any significant indications i.e. (odour, taste, irritation) required special regulations for the duration of use and correct usage. Particle and combined filters must be replaced atleast when breathing resistance becomes too high. Disposal Contaminated products should be disposed as per hazardous waste in accordance with local regulations.
  • Page 8: Material Of Construction

    Classification Max breathing resistance (mbar) according IS 15323 Flowrate 95 l/min A2 E1 5.6/4.0 ABEK1 ABEK1 P3 Protection Capacity The minimum capacities and breakthrough times of gas filter cartridge are tested at a flowrate of 30 l/min Category Test Gases Concentration Minimum Breakthrough Time Cyclohexane...
  • Page 9: Spare Parts

    Do not use the respirator in environment that contain less than 17% oxygen If you do not achieve a proper fit DO NOT enter the contimated area. See your supervisor immediately. Venus Offers advice on the selection of products, and training in the correct fitting and usage. Manufacturer name & address VENUS Safety &...

This manual is also suitable for:

V-7900 series