I N S T A L L A T I O N
Quickstart Exterior - 9325e
1. Connect the black pair of wires to a 12VDC supply.
Observe proper polarity see Fig.1
2. The white pair of wires provide connection to a field
selectable N/O or N/C SPST relay (see Fig. 1).
3. The gray pair of wires may be connected to a normally
open switch (for example: a N/O pushbutton switch) to
operate the electric release from the secure side
of the door.
Fig. 1
Black/White
9325e wiring
Wire
connections
Gray
Wires
Fig. 2
9325i wiring
connections
Quickstart Interior - 9325i
1. Connect a 12VDC supply to the power terminals of the
keypad. Observe proper polarity as illustrated in Fig.2
2. Connect the device to be controlled by the keypad to
the relay terminals of the keypad. These terminals can
operate as a N/O or N/C relay or a 12VDC powered
output. See connection diagram in Fig. 2. The Relay
terminals operate as a SPST relay by default, if a 12VDC
powered output is desired see Fig. 9 for details.
3. Connect a N/O pushbutton to the Exit button terminals if
desired. A button wired to these terminals may be used
to operate an electric release from a remote location.
IS9325
www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com
+
-
Black Wire
White Wires
1
2
3
4
5
6
7
8
9
*
#
0
+
Exit
Button
Power
Relay
May be SPST relay
or 12VDC output.
J2
(See Fig. 9 for
J3
details.)
J4
© 2014 RuTheRfoRd CoNTRolS INT'l | A doRMA GRouP CoMPANy
First – the master code must be set (allows access to all
keypad settings).
The first time the keypad is turned on, the green and red
LEDs will flash alternately.
Choose a 6 digit number and make a note of it here. This will
be the new master code.
Press * followed by the new master code then...
Press * and re-enter the new master code then...
Press * to confirm the code, and finish.
Now that the master code is defined, type 7890 on the
keypad. The door should open.
Note: The master code must not contain a user code (for
example: 123456 as a master code and 1234 as a user code
would cause the door to open before the master code had
been entered. A full system reset would be required).
Then set the user code (opens the door).
Choose an entry code (at least 4 digits, but not more than 8)
and make a note of it here. This will be the new user entry
code.
Enter the 6 digit master code (green and red start flashing
together).
+
Press and hold down 8 for 3 seconds then...
Enter the new user entry code and press * then...
Re-enter the new user entry code and press * then...
Press 1 to confirm the code.
Press # to exit programming mode.
Resetting
If you want to start again, simply turn off the power to
the keypad. Press and hold the 3 (or 2) while turning the
power back on. This will reset everything back to the factory
settings.
Multiple codes
For more than one user code, see page 3 programming that
allows the keypad to accept multiple user codes.
The factory default user code 7890 should be deleted once
the new multi-codes have been entered.
In multi-user mode, a [*] is required after the user code to
unlock the door.(for example, 1234*).
Access Keypad
Quickstart Programming
master code
user code
9325
PCN14014
R07/14TG-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RCI 9325 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dorma RCI 9325

  • Page 1 A button wired to these terminals may be used unlock the door.(for example, 1234*). to operate an electric release from a remote location. © 2014 RuTheRfoRd CoNTRolS INT’l | A doRMA GRouP CoMPANy IS9325 PCN14014 www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com...
  • Page 2 The cable clamp is screwed down to hold the cable firmly at the back of the keypad. © 2014 RuTheRfoRd CoNTRolS INT’l | A doRMA GRouP CoMPANy www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com...
  • Page 3: Programming Codes

    This returns all the settings (except multi-user) to the factory defaults with a single user code of 7890. This does not change the master code. Exit programming mode * = Factory defaults © 2014 RuTheRfoRd CoNTRolS INT’l | A doRMA GRouP CoMPANy www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com...
  • Page 4: Programming Descriptions

    Remember to delete the factory default user code 7890 loading goods into the room. after entering multi-user codes. © 2014 RuTheRfoRd CoNTRolS INT’l | A doRMA GRouP CoMPANy www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com...
  • Page 5: Specifications

    This is a 6 digit code which must be set by the user the first time the keypad is powered up. © 2014 RuTheRfoRd CoNTRolS INT’l | A doRMA GRouP CoMPANy www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com...
  • Page 6 9325e relay. interior 9325i relay. – The RCI 9325 keypad can be used to directly control an electromagnetic lock or electric door strike by changing the output. Model number 9325i is preset at factory default with output configured as SPST N/O relay. By changing...
  • Page 7 White Wire N/O Pushbutton (If Required) Gray Wires Fig. 11 Typical wiring of an electromagnetic lock through the exterior 9325e relay. © 2014 RuTheRfoRd CoNTRolS INT’l | A doRMA GRouP CoMPANy www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com...
  • Page 8: R E F E R E N C E C H A R T

    1-1/2A Length of Wire Run (ft.) 1000 1500 Wire Gauge Chart courtesy of Electronic Locking Devices by John L. Schum © 2014 RuTheRfoRd CoNTRolS INT’l | A doRMA GRouP CoMPANy www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com...