Page 2
Operating manual ERS2 series Important safety information Read this manual before attempting to install the device! Failure to observe recommendations included in this manual may be dangerous or cause a violation of the law. The manufacturer, ElektronikSystem i Umeå AB will not be held responsible for any loss or damage resulting from not following the instructions of this operating manual.
Operating manual ERS2 series Contents Description ....................1 Dimensions (mm) ................1 Label ....................2 Main features of the ERS2 series ............3 Mounting guidelines ................... 4 Motion PIR ..................4 Room occupancy sensor..............4 Sound level ..................4 Installation ....................5 Service and maintenance ................
Page 4
Operating manual ERS2 series Light ....................13 CO2 ....................13 Motion PIR ..................13 7.5.1 PIR Lens detection pattern..............14 Room occupancy (ERS2 Eye) ............15 7.6.1 Detailed description ................15 7.6.2 Special functions for ERS2 Eye ............15 Sound level ..................16 VOC ....................
Operating manual ERS2 series 1. Description The ERS2 series of sensors are universal LoRaWAN indoor climate sensors. ® The sensor measures, depending on model, temperature, humidity, light intensity, CO2-level, sound-level, volatile organic compounds (VOC), occupancy and detects motion. ERS2 is a battery-powered device and is designed to be wall-mounted.
Operating manual ERS2 series 1.2 Label At the back of your device there is a label with an Aztec barcode containing DevEUI and sensor type. ElektronikSystem i Umeå AB Tvistevägen 48C, 90736 Umeå, Sweden E-mail: support@elsys.se ǀ Web: www.elsys.se...
Operating manual ERS2 series 1.3 Main features of the ERS2 series • Compatible with LoRaWAN specification 1.0.4 ® • Measures ambient temperature • Measures ambient humidity • Measures light intensity* • Measures CO2 level* • Measures sound level* • Measures VOC level* •...
Operating manual ERS2 series 2. Mounting guidelines Common mounting guidelines for ERS2 line of sensors: • Place the sensor in an open space on the wall, with an installation height of 1.6 meters (does not apply to ERS2 Eye, see 4.2).
Operating manual ERS2 series 3. Installation 1. Remove the back panel of the sensor by gently prying the tab with a small screwdriver. 2. Install the batteries. The ERS2 requires one or two AA batteries. The battery type is 3.6V Lithium Battery (ER14505). You can use one battery, but it’s recommended that you use two for best battery life.
Operating manual ERS2 series 3. Mount the back panel securely to the wall with at least 2 appropriate screws, using some of the four mounting holes. Alternatively, attach the sensor with double sided adhesive tape. 4. Attach the sensor part by hinging it on the back panel.
NFC to make end-users unable to read or change settings on the sensor. 5.1 NFC Configuration 1. Download ELSYS “Sensor Settings” application from Google Play or App store and install it on a smartphone or tablet. The device must support NFC.
Operating manual ERS2 series 5.2 Over the air configuration All settings may be configured over the air via your LoRaWAN infrastructure. ® Please visit the support section on our webpage for more information regarding downlink protocol. 5.3 Application parameters All parameters for the “Sensor settings” application can be found in our settings document.
Operating manual ERS2 series 6. Sensor behavior 6.1 Sensor startup 1. When the sensor starts up it loads any configuration parameters written to the NFC chip. The sensor will then write all configuration parameters back to the NFC chip. 2. When the configuration is done the sensor tries to join the network if OTAA (Over the Air Activation) is enabled.
Operating manual ERS2 series 6.4 LED indication The LED, located in the bottom right corner, indicates different actions when the sensor is active. LED indication Action Long red blink, long green blink Sensor is starting up Short yellow blink LoRa join request transmission...
Operating manual ERS2 series 7. Internal sensors The populated internal sensors in the ERS2 series differ between models according to the list below. ERS2 ERS2 ERS2 ERS2 ERS2 ERS2 ERS2 Lite CO2 Lite Sound Temperature Humidity Light Motion PIR Room...
Operating manual ERS2 series 7.1 Temperature Resolution: 0.1 °C Accuracy: 0.2 °C typical, see figure 7.2 Humidity Resolution: 1 % RH Accuracy at 25 °C: ±2 % RH, see figure Accuracy of RH over temp.: See figure ElektronikSystem i Umeå AB Tvistevägen 48C, 90736 Umeå, Sweden E-mail: support@elsys.se...
Operating manual ERS2 series 7.3 Light The light sensor sits behind the PIR lens. For correct reading, make sure it isn’t obstructed. Accuracy can depend on angle of light source. Range: 0-65535 lux Accuracy: ± 10 % or ± 10 lux, whichever is greater.
Operating manual ERS2 series 7.5.1 PIR Lens detection pattern Lens for ERS2, ERS2 CO2, ERS2 Sound and ERS2 VOC (wall mount) From side From top Lens for ERS2 Eye (ceiling mount) From side From top ElektronikSystem i Umeå AB Tvistevägen 48C, 90736 Umeå, Sweden E-mail: support@elsys.se...
Operating manual ERS2 series 7.6 Room occupancy (ERS2 Eye) The room occupancy algorithm uses both the PIR sensor and an 8x8 pixel heat map sensor. If the PIR triggers, occupancy is detected. If the PIR doesn’t trigger, the heat map is enabled, and its pattern is compared to a filtered mean value of the room.
Operating manual ERS2 series 7.7 Sound level The sound level sensor continuously measures the average and peak sound pressure level with no missing events. The analog part is always on, with a peak- hold circuit for peak level, and a mean-value filtering for average value. The digital part wakes and samples both signals every 10 s and does the final calculation before sending the data at the desired send interval.
Operating manual ERS2 series 8. Device specifications Mechanical specifications Dimensions 76,4 x 76,4 x 22.5 mm Weight 53 – 60 g excluding batteries / 70 – 95 g (depending on model) including batteries Enclosure Plastic, PC / ABS IP rating...
All information, including, but not limited to, information regarding the features, functionality, and/or other product specification, are subject to change without notice. ELSYS reserves all rights to revise or update its products, software, or documentation without any obligation to notify any individual or entity. ELSYS and ELSYS logo are trademarks of ElektronikSystem i Umeå...
Page 23
Operating manual ERS2 series Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Operating manual ERS2 series this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •...
Need help?
Do you have a question about the ERS2 Series and is the answer not in the manual?
Questions and answers