U.S. standard external power supply details where some information (for example the AC transformer input voltage) will not be applicable for British/European use. Please note, however, that when a power supply adapter is ordered from Campbell Scientific it will be suitable for use in your country.
Mount features: The CM225 can be mounted horizontally on a crossarm or vertically on a mast or pole while maintaining a level mounting plate. The CM226 mounts on a mast, crossarm, or pole up to 5 cm (2 in) in diameter. It includes a leveling base required for smaller sensors, such as the Apogee CS301.
Claims for shipping damage must be filed with the shipping company. Locate the packing slip for the order and compare the items listed on the packing slip to the items that were actually shipped. Report any discrepancies to Campbell Scientific. Solar Radiation Sensor Mounts...
4. Overview Campbell Scientific solar radiation sensor mounts provide a stable mounting platform for a pyranometer, quantum sensor, or radiometer. The flexibility in these designs allows a sensor to be mounted to a horizontal crossarm, or to a vertical mast or tower. The CM255 and CM256 may be mounted at different angles, depending on the user’s needs...
Mounts to Sensors Consists of a simple CM202, CM202SS, stainless steel bent sheet CS300 , LI200X CM203, CM204, metal bracket and U-bolt. CM225 LI200S , LI190R CM204SS, or CM206 Dimensions are LI190SB , CMP3, CMP6 crossarm, mast, or Solar Sensor 8.9 x 11.3 x 6.4 cm...
Page 8
Compatible Mount Description Mounts to Sensors –SP option: MS-40/60/80, MS-40M/60M/80M, SR30, SR05, SR11, SR15, SR20-T2, SR20-D2, Includes leveling screws SP Lite 2, that allow leveling in a CMP3/6/10/11/21/22, horizontal position and CM202, CM202SS, SMP3/6/10/11/21/22, then pivoting or tilting to CM256 CM203, CM204, CGR3/4, SGR3/4, SPN1, the correct azimuth.
Page 9
Compatible Mount Description Mounts to Sensors Solar mount bracket MS-40/60/80, designed to be mounted MS-40M/60M/80M, horizontally or vertically SR30, SR05, SR11, SR15, on a Unistrut with a SR20-T2, SR20-D2, CM266 1.625 in (4.128 cm) 1 5/8 inch Unistrut in SP Lite 2, strut channel.
–CV option: CVF4 Retired sensors may also be compatible. Contact Campbell Scientific for more information. A leveling base is required to mount the CS300, LI200X, LI200S, LI190R, or LI190SB. Assumes the CMP6, CMP11, and CMP21 are not housed in the CVF4 Heater/Ventilation Unit.
parallel to the sensor surface. Site the sensor to allow easy access for maintenance while ideally avoiding any obstructions or reflections above the plane of the sensing element. Mount the sensor such that a shadow or a reflection will not be cast on it at any time. Figure 6-1 (p.
Page 12
2. Secure the solar radiation sensor to the mounting bracket. Refer to Figure 6-2 (p. 9) to determine which mounting holes are used by the sensor. Visually inspect the leveling feet on the sensor (if present) to ensure all feet are in contact with the mounting bracket. Figure 6-2.
Page 13
4. Secure the mounting bracket to the crossarm or the vertical pole using the hardware included with the mounting bracket. The CM225, CM255, and CM261 use one or two U-bolts, nuts, flat washers, and lock washers to mount the bracket (Figure 6-3 [p.
Page 14
5. The CM256 and CM275 bracket (Figure 6-4 [p. 11]) use two set screws to secure the crossarm or the pole in the channel at the base of the bracket. For pyranometers mounted horizontally, ensure the mounting bracket is horizontal in two dimensions. For pyranometers to be mounted at an angle with the CM255 or CM256, set the mounting bracket angle to the desired angle prior to tightening the mounting hardware.
Page 15
6. The CM226 uses two bolts, wing nuts, and a clamp piece to secure it to a crossarm or mast (Figure 6-5 [p. 12]). Figure 6-5. CM226 showing horizontal and vertical mount options Solar Radiation Sensor Mounts...
Page 16
7. The CM266 can be mounted vertically or horizontally on a Unistrut. To install, insert the bolt through the front of the mounting plate and thread the Unistrut nut onto the bolt by two turns. Slide the Unistrut nut into the Unistrut, making sure the two tabs on the CM266 also slide into the Unistrut to lock its orientation.
8. The CM268 clamps onto the edge of a solar panel, aligning the mount with the panel's orientation. To install, loosen the bolt securing the clamp on the CM268. Slide the clamp over the bottom edge of the solar panel then pivot the CM268 up so the tab slides over the top of the solar panel.
2. The defect cannot be the result of misuse. 3. The defect must have occurred within a specified period of time; and 4. The determination must be made by a qualified technician at a Campbell Scientific Service Center/ repair facility.
Page 19
Campbell Scientific’s Terms, the provisions of Campbell Scientific’s Terms shall prevail. Furthermore, Campbell Scientific’s Terms are hereby incorporated by reference into this Warranty. To view Terms and conditions that apply to Campbell Scientific, Logan, UT, USA, see Terms and Conditions ...
Page 20
Please state the faults as clearly as possible. Quotations for repairs can be given on request. It is the policy of Campbell Scientific to protect the health of its employees and provide a safe working environment. In support of this policy, when equipment is returned to Campbell Scientific, Logan, UT, USA, it is mandatory that a “Declaration of Hazardous Material and...
Page 21
Comply with all electrical codes. Electrical equipment and related grounding devices should be installed by a licensed and qualified electrician. Only use power sources approved for use in the country of installation to power Campbell Scientific devices. Elevated Work and Weather Exercise extreme caution when performing elevated work.
Page 22
Periodically (at least yearly) check electrical ground connections. WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL SCIENTIFIC PRODUCTS, THE CUSTOMER ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER INSTALLATION, USE, OR MAINTENANCE OF TRIPODS,...
Page 23
Campbell Scientific Regional Offices Australia France Spain Location: Garbutt, QLD Australia Location: Montrouge, France Location: Barcelona, Spain Phone: 61.7.4401.7700 Phone: 0033.0.1.56.45.15.20 Phone: 34.93.2323938 Email: info@campbellsci.com.au Email: info@campbellsci.fr Email: info@campbellsci.es Website: www.campbellsci.com.au Website: www.campbellsci.fr Website: www.campbellsci.es Brazil Germany Thailand Location: São Paulo, SP Brazil...