FEATURES

Overview

  1. Skin cooling ducts
  2. Treatment Window
  3. Protective shield
  4. Self-adjusting head
  1. Device cooling vent
  2. Flash button
  3. P lus & minus buttons
  4. Indicator lights
PACKAGE CONTENTS
  • Device
  • Power cable
  • Four [4] plug adapters
  • Cleaning cloth
  • Quick start guide
  • User manual

SKIN TONE: PEACH devices are suitable for use on light, medium and dark skin tones, up to and including skin tone 5.

HAIR COLOR: PEACH devices are suitable for use on naturally black or brown hair. They may not be as effective on white, grey, blonde or red hair.

Congratulations on taking the first step toward discovering smarter hair removal by acquiring PEACH. Before you begin to enjoy all the benefits of its sophisticated technology in the comfort of your home, please take a few moments to carefully read the instructions in this manual.

Please READ ALL INSTRUCTIONS BEFORE USE and utilize these devices only for their intended use as described in this manual.

INTENDED USE: PEACH devices are over-the-counter devices intended for the removal of unwanted body hair and/or facial hair.

BODY AREAS: PEACH devices are suitable for use on body hair and female facial hair below the cheek line.


NO MODIFICATION OF THIS EQUIPMENT IS ALLOWED.

HOW DO PEACH™ DEVICES WORK?

PEACH devices are designed to help break the cycle of hair growth. Light energy is transferred through the skin's surface and is absorbed by melanin present in the hair shaft. The absorbed light energy is converted to heat energy (below the surface of the skin), which disables the hair follicle. Treated hairs naturally fall out over the course of a few days to 1-2 weeks. Hair growth is cyclical and follows 3 distinct and consecutive phases. IPL treatment is only effective when hairs are in a particular phase (the Anagen – growth phase). Not all hairs are in the same phase at any one time. This is why you should follow the recommended treatment regimen of 1 treatment every week, for 12 weeks.

WHAT TO EXPECT

Immediately post treatment, you should not see any significant side effects from treatment (Refer to section titled 'Side Effects' for more information on side effects).

In the first few weeks following the initial treatments, you will still see some hairs growing. These are likely to be hairs that were missed during treatment i.e. they were lying dormant and not in their growth phase (Anagen) during treatment; when IPL is most effective.

Around 6 weeks into the 12 week treatment program you should see a reduction in hair growth. However, many hairs may still not have been treated in their growth phase. It is important to continue the treatments every week. After the 12 week program, you should see a significant reduction in hairs within the treated area. Any remaining hairs should be finer and / or lighter in color. Continued monthly treatments, or treatments as required, should maintain the reduction in unwanted hair.

IMPORTANT SAFETY INFORMATION

CONTRAINDICATIONS
Do NOT use the devices:

  • if your skin is darker than skin tone 5 shown on the skin tone chart above. Since dark skin absorbs more light energy, treating very dark skin may cause discomfort/pain and adverse effects (e.g., burns, blisters, discoloration or scarring) and injure your skin.
  • you are pregnant, lactating, or under the age of 18 as these devices have not been tested with these individuals.
  • you have a history of skin cancer or precancerous lesions (e.g., nevi or a large number of moles).
  • your skin has been artificially or naturally tanned recently, or is burned from sun overexposure. Your skin may be sensitive following sun exposure and particularly susceptible to side effects of IPL treatment (e.g., burn, blister, discoloration or scarring). Wait 1 week until sunburn or tan disappears before using the devices.
  • directly on the nipples, genitals or around the anus. These areas may have a darker skin color and/or greater hair density. Using the devices in these areas may cause discomfort/pain or injure (burn, discolor or scar) your skin.
  • on blisters, scars, dark brown or black spots such as birthmarks, moles or warts in the area you wish to treat. Or the devices may injure your skin or make existing conditions worse, and you may particularly susceptible to side effects of IPL treatment (e.g., burn, blister, discoloration or scarring)
  • if you have any skin condition in the treatment area, including psoriasis, vitiligo, eczema, acne, herpes simplex or active infections or wounds.

DO NOT expose treated areas to the sun. Wait at least 7 days after treatment before exposing treated skin to direct sunlight. Your skin may be extra sensitive following an IPL treatment and particularly susceptible to sunburn. Apply sunscreen (SPF 15 or greater) to the treated area or cover the treated area with suitable clothing.

If you are unsure whether these devices are safe for you to use, please consult your physician or dermatologist.

If you take any kind of medication regularly and over a long period of time, please consult your physician for any potential impact on skin sensitivity to light.

EYE SAFETY

PEACH devices emit flashes of intense pulsed light. Direct exposure is potentially harmful to your eyes. Take care to follow the safety precautions below.


Possible eye injury (potentially leading to loss of vision) or skin injury if instructions are not followed. Read and follow the instructions.

The devices should only be activated (flashed) if they are in full contact with the skin. However:

DO NOT:

  • look directly into the treatment window of the devices when they have electrical power and are switched on.
  • attempt to activate (flash) the devices towards the eye.
  • treat areas around the eye (eyebrows or eyelashes). Misuse can lead toeyedamage.
  • use the devices over the eyelids or close to the eye. ONLY attempt to activate (flash) the device when the treatment window is in full contact with the area you wish to treat.

WE RECOMMEND you look away from the devices when firing onto your skin.

ELECTRICAL AND SAFETY
As with any electrical device, certain precautions must be taken in order to ensure your safety.

DO NOT:

  • try to open the devices, as this may expose you to dangerous electrical components.
  • use if the PEACH devices are is damaged; for example, cracked device, cable damage (internal wires visible), cracked or broken glass on the device, etc. This may result in injury.
  • use near bathtubs, showers, basins or other vessels containing water. If the devices become wet, they should not be used.
  • use if the devices becomes uncomfortably hot to touch. This may indicate that the unit is damaged.
  • use a power supply or other component, other than those provided for use with PEACH devices. This may damage the devices and cause it to stop working.
  • attempt to activate (flash) the devices on any surface other than skin.
  • position the devices so that they are difficult to disconnect from the mains supply.

GENERAL SAFETY
DO NOT:

  • use if you have had a skin peel treatment on the area you wish to treat. Please wait 30 days after a skin peel before treating with the devices. Treating tanned skin with Intense Pulsed Light (IPL) may result in permanent hyperpigmentation (darkening) or hypopigmentation (lightening) of the treated skin.
  • use on areas where you have tattoos or permanent make up.
  • use the devices over any fillers or botox.
  • use if you have a known sensitivity to sunlight (photosensitivity) or are taking medication that makes the skin more sensitive and causes photosensitivity, e.g., Retin A, Accutane and/ or other topical retinoids. Always check the instruction leaflet that comes with your medicinal product, to see if photosensitivity is listed as a side effect. Use of the devices on photosensitive skin could result in skin damage such as swelling or blisters. Seek medical advice prior to use of the devices as use may harm the skin. These devices are not intended for the treatment of medical conditions. Medical advice should be sought to address, for example, moles, skin rash, itchy skin, skin fungus or infection, skin bumps, or skin tags.
  • touch the treatment window during or directly after use. Regularly inspect the treatment window for damage.
  • touch the device cooling vent (metal part) of the devices during or directly after use.
  • use the devices if the treatment window is cracked or missing.
  • Ensure that the treatment window is clean and free from debris. Any debris on or around the treatment window during operation may result in temporary skin changes such as redness or swelling.
  • The devices should be kept out of the reach of children under 18 years of age. Children should not use, play with, maintain or clean the devices. There are a number of potential risks – exposure to the light output causing burns or eye damage, electrocution, strangulation from the cables.
  • The devices should be kept out of reach of pets and pests which could damage the devices. Potential risks include reduced function and electrocution.
  • The devices are not intended for use by persons with reduced physical, sensory or mental capabilities. Unless they have been given supervision or instruction concerning safe and proper use of the devices by a person responsible for their safety.
  • The devices' treatment window is a critical component that will get hot during use.

  • DO NOT exceed the usage specified in the treatment regime.
  • Damage of the skin may occur after prolonged or repeated application on one site. Avoidoverusage which includes excessive passes, stacking of flashes and/or increased frequency of use.
  • Do not override the safety mechanisms inherent to the devices.

PRECAUTIONS

  • Hair removal by lasers or intense pulse light sources can cause increased hair growth in some individuals. Based upon currently available data, the highest risk groups for this response are females of Mediterranean, Middle Eastern, and South Asian heritage treated on the face and neck.
  • DO NOT use the devices on any area where you may want hair to grow back.
  • DO NOT use on the scalp, eyebrows or anywhere near or around the eyes. Use in these areas may permanently damage your eyes.
  • DO NOT use the devices on man's face, jaw, or neck. The hair in a man's beard area is too dense and using an IPL device in these areas may result in skin injury.
  • These devices are not recommended for use on red, grey, white or blonde hair. They are not effective on these hair colors.

POTENTIAL RISKS, SIDE EFFECTS AND SKIN REACTIONS

SIDE EFFECTS HOW TO ASSESS & REACT
Mild pain / discomfort in the area being treated This is expected and is normal for all IPL treatments. You can keep on using the device as instructed, and the pain should diminish with continued use
Warm feeling or tingling sensations during treatment, which typically dis- appear after a few seconds to a minute and decrease with continued use. This is expected and is normal for all IPL treatments. You can keep on using the device as instructed.
Itchiness in the treatment area. This is quite common for IPL treatments, and should subside after a short period. You can keep on using the device as instructed. Do not scratch the area.
Skin redness during or after treatment which disappears within minutes. This is expected and is normal for all IPL treatments. You can keep on using the device as instructed once skin redness has disappeared.
Skin redness which does not disappear within minutes and lasts 24-48 hours. Stop using the device immediately and consult your physician before using it again.
Pain or discomfort that is intense during treatment or persists after a treatment. Stop using the device immediately and consult your physician before using it again.
IN VERY RARE CASES HOW TO ASSESS & REACT
Swelling and redness that does not disappear within two to three days. Stop using the device immediately and consult your physician before using it again.
Temporary changes in skin color (lightening or darkening). If your skin color changes, stop using the device immediately and consult your physician.
Blistering, scarring or burning of the skin. Stop using the device immediately and consult your physician before using it again. Apply a cold pack to the area. Treat with antiseptic or burn cream.

HOW TO USE


Follow each step in the treatment process ensuring you complete all aspects of each step before progressing to the next.

PREPARE THE TREATMENT AREA

Remove any visible hair on the skin before using the device. We recommend shaving body hair and dermaplaning facial hair, for optimal results. Make sure there is no hair remaining above the surface of the skin as this may cause injury. This also prevents debris from covering the front of your device. Clean the treatment area and pat it dry.

TURN ON THE DEVICE

Attach the relevant plug adapter to the power cable. Then use the power cable to connect the device to an electrical outlet. The device will turn on automatically. You can adjust to your preferred intensity level using the + and - buttons.

information NOTE: Levels 1 - 3 on your device are intended for sensitive areas and first time users. With reduced light intensity, more treatments may be required to see the desired effects. As long as the treatment feels comfortable, increase the setting by one level.

PATCH TEST

Before your first treatment on each new body area, we RECOMMEND you test your skin in that area for a reaction to the device. The patch test area should be approximately 3cm x 3cm in size (equivalent to 1 flash from PEACH). Perform the patch test as described below in the 'Treatment Methods' section, under 'Stamp Mode'. Wait 24 hours following the patch test, to ensure your skin is suitable for treatment and there is no adverse reaction to the light energy. If there is no reaction after 24 hours, you may treat the area around the patch test. The 'patch tested area' should NOT be re-treated for at least 1 week. If a skin reaction develops, discontinue using the device and consult your physician.

TREATMENT METHODS

The area to be treated must be hair-free, clean and dry. Before pushing the flash button, look away from the device to avoid the bright light. In rare cases, you may find the flash too bright. There is no safety risk associated with this. For increased comfort, we recommend treating in a well-lit room to help reduce the perceived brightness. However, if you find the light is still too bright, we recommend wearing sunglasses for extra eye protection. We also recommend wearing sunglasses for extra eye protection when using the device to remove hair on the face.

GLIDE MODE

For fast & efficient treatment of large areas - like the legs, arms, chest, back & stomach

  1. Place the treatment window firmly on your skin, and select your preferred intensity level.
  2. Press and hold the flash button. The device will begin to flash.
  3. Glide the device slowly and continuously from the bottom to the top of the treatment area. Make sure to always keep full skin contact so that the device flashes continuously.
  4. Once the gliding stroke is complete, lift the device off the treatment area.
  5. Repeat to treat the next adjacent area in a parallel glide, until you have completed the entire area you wish to treat.

STAMP MODE

For treating small or hard-to-reach areas - like the face, bikini line & underarms

  1. Place the treatment window firmly on your skin, and select your preferred intensity level.
  2. Press and instantly release the flash button. The device will emit a flash.
  3. Lift the device off the skin, and place it onto the next adjacent spot to be treated.
  4. Continue treatment spot by spot, until you have completed the entire area you wish to treat.

information NOTE:

  • The silicone shield on your PEACH device must be in full contact with your skin.
  • For a PEACH device to work effectively, you must use it evenly all over your skin, without missing any spots. Make sure you avoid missed areas by placing the treatment window directly next to the previously treated spot, without leaving any space between treated areas. However, make sure that you do not flash the same area more than once. This does not improve the effectiveness of the treatment, and can instead increase the risk of skin reactions.
  • PEACH devices are designed to be powerful, for maximum results. When used for an extended period of time, your device may temporarily pause to cool down and prevent overheating, as a safety feature. If this occurs, the indicator lights will blink, and the flash button will become inactive. In this case, simply wait a few minutes for the device to cool down, then resume your treatment. Additionally, your device may automatically adjust the flash speed to be slower, allowing it to maintain a comfortable temperature and consistent performance throughout the remainder of your session.
  • If you feel intense pain, stop treatment immediately and consult your physician before using the device again.

YOUR PEACH TREATMENT SCHEDULE

For optimal results, the device should be used once every week for 12 weeks to ensure all hair follicles are treated.

After the initial treatment phase (once every week for 12 weeks), to maintain results we recommend using the device once a month, or as required.


Always wait 7 days before treating the same area again

  • Treat yourself within 3 days of the planned treatment date. If you have not treated yourself within 3 days after the planned treatment date, restart the initial phase.

CLEANING, MAINTENANCE, STORAGE

After treatment, always switch off the device by unplugging the power supply from the device and the electrical outlet.

After each use, the treatment window should be thoroughly wiped with a slightly damp, lint free cloth. It is particularly important to keep the front of the device and skin cooling ducts free from dirt, hair or other debris to ensure maximum performance.


The treatment window can get hot during use. DO NOT touch or clean the treatment window for at least 5 minutes after use to allow it to cool down.

information NOTE:

  • Never use cleaning products containing alcohol, petrol or acetone, as they may irritate the skin and damage the silicone.
  • Be careful to avoid getting water in any openings in the device, including the skin cooling ducts.

TROUBLESHOOTING

PROBLEM SOLUTION
The device does not turn on.
  • Make sure the power supply is plugged in.
  • Your device is locked. To unlock it, register your device via the FOREO app (instructions above in the 'How To Use' section)
The flash button does not respond.
  • Make sure the treatment window is in full contact with your skin.
  • Unplug the device. Then plug it back in.
The device won't sync to the FOREO app.
  • Switch your Bluetooth off and then on again to try reconnecting.
  • Close the FOREO app and then reopen it to start the process over.
  • Check to see if the app needs to be updated in your mobile device's app store.
The device, treatment window, power supply or cable are damaged, broken, cracked or appear defective. DO NOT USE. If you are in any doubt about the safety of the device or suspect it is damaged in any way, it must not be used. And you should refer to the website.

If you do not find the answer to your specific question, or if you have any other questions regarding the device's operation, please visit foreo.com/support.

TECHNICAL SPECIFICATIONS

PEACH devices are filtered broadband Intense Pulsed Light systems with the following technical specifications:

PEACH™ 2 / PEACH™ 2 go PEACH™ 2 Pro Max
REPETITION RATE 0.5 -1s 0.5 -1s
PULSE LENGTH Free discharge 3ms Free discharge 3ms
MAX OPTICAL OUTPUT 3.3-5.6 J/cm² 10.4 J/cm² *
WAVELENGTH 550 - 1100nm 550 - 1100nm
POWER LINE INPUT 100 - 240V, 50/60Hz 3A 100 - 240V, 50/60Hz 3A
OPERATING TEMPERATURE 5 Celsius to +40 Celsius 5 Celsius to +40 Celsius
OPERATING HUMIDITY 40% to 80% 40% to 80%
OPERATING PRESSURES 800 to 1,060 hPa 800 to 1,060 hPa
TREATMENT AREA (SPOT SIZE) 4.5 cm² 11.5 cm²

* in some countries the max optical output may be lower due to regulations.

Below cable information is provided for EMC reference:

CABLE MAX CABLE LENGTH, SHIELDED / UNSHIELDED NUMBER CABLE CLASSIFICATION
AC Power Line 1.5m, Unshielded 1 Set AC Power

IMPORTANT INFORMATION REGARDING ELECTROMAGNETIC COMPATIBILITY (EMC)
This electrical medical equipment needs special precautions regarding EMC and is put into service according to the EMC information provided in the user manual. The equipment conforms to this IEC 60601-1-2:2014+A1:2020 standard for both immunity and emissions. Nevertheless, special precautions need to be observed:

  • The equipment with no ESSENTIAL PERFORMANCE is intended for use in a home healthcare environment.
  • The use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.

  • Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
  • Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 12 inches (30 cm) to any part of the device, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
  • Use of accessories and cables other than those specified or provided byFOREO could result in increased electromagnetic emission or decreased electromagnetic immunity of the equipment and result in improper operation.

STATEMENT: For the purpose of its operation, the equipment has wireless communication function, it includes RF transmitter and receiver, 2.4GHz, Pulse modulation.

Table 1: EMC Compliance - Emission

PHENOMENON COMPLIANCE ELECTROMAGNETIC ENVIRONMENT
RF Emissions CISPR 11 Group 1, Class B Home healthcare environment
Harmonic distortion IEC 61000-3-2 Class A Home healthcare environment
Voltage fluctuations and flicker IEC 61000-3-3 Compliance Home healthcare environment

Table 2: EMC Compliance - Enclosure Port

PHENOMENON BASIC EMC STANDARD IMMUNITY TEST LEVELS HOME HEALTHCARE ENVIRONMENT
Electrostatic IEC 61000-4-2 ±8 kV contact
Radiated RF EM field IEC 61000-4-3

10V/m

80MHz-2.7GHz

80% AM at 1kHz

Proximity fields from RF wireless communications equipment IEC 61000-4-3 Refer to table 3
Rated power frequency magnetic fields IEC 61000-4-8 30A/m 50Hz or 60Hz
Proximity magnetic fields IEC 61000-4-39 Refer to table 4

Table 3: Proximity fields from RF wireless communications equipment

TEST FREQUENCY (MHz)

BAND

(MHz)

IMMUNITY TEST LEVELS HOME HEALTHCARE ENVIRONMENT
385 380-390 Pulse modulation 18Hz, 27V/m
450 430-470 FM, ±5kHz deviation, 1kHz sine, 28V/m
710 704-787 Pulse modulation 217Hz, 9V/m
745
780
810 800-960 Pulse modulation 18Hz, 28V/m
870
930
1720 1700-1990 Pulse modulation 217Hz, 28V/m
1845
1970
2450 2400-2570 Pulse modulation 217Hz, 28V/m
5240 5100-5800 Pulse modulation 217Hz, 9V/m
5500
5785

Table 4: Proximity magnetic fields

FREQUENCIES TEST LEVEL [A/M] MODULATION
30 kHz 8 CW
134,2 kHz 65 Pulse modulation 2,1 kHz
12,56 MHz 7.5 Pulse modulation 50 kHz

Table 5: Input AC Power Port

PHENOMENON BASIC EMC STANDARD IMMUNITY TEST LEVELS HOME HEALTHCARE ENVIRONMENT
Electrical fast transient/burst IEC 61000-4-4 ±2 kV
100kHz repetition frequency
Surges Line-to-line IEC 61000-4-5 ±0.5 kV, ±1 kV
Surges Line-to-ground IEC 61000-4-5 ±0.5 kV, ±1 kV, ±2 kV
Conducted disturbances induced by RF fields IEC 61000-4-6 3V, 0.15MHz-80MHz
6V in ISM bands and amateur radio bands between 0.15MHz and 80MHz 80%AM at 1kHz
Voltage dips IEC 61000-4-11 0% U T; 1 cycle and
70% U T; 25/30 cycles Single phase: at 0º
Voltage interruptions IEC 61000-4-11 0% U T; 250/300 cycles

Table 6: Signal Input /Output Parts Port

PHENOMENON BASIC EMC STANDARD IMMUNITY TEST LEVELS HOME HEALTHCARE ENVIRONMENT
Electrical fast transient/burst IEC 61000-4-4 ±1 kV
100kHz repetition frequency
Conducted disturbances induced by RF fields IEC 61000-4-6 3V, 0.15MHz-80MHz
6V in ISM bands and amateur radio bands between 0.15MHz and 80MHz 80%AM at 1kHz

Table 7: PATIENT coupling PORT

PHENOMENON BASIC EMC STANDARD IMMUNITY TEST LEVELS HOME HEALTHCARE ENVIRONMENT
Electrostatic Discharge IEC 61000-4-2 ±8 kV contact
±2kV, ±4kV, ±8kV, ±15kV air
Conducted disturbances induced by RF fields IEC 61000-4-6 3V, 0.15MHz-80MHz
6V in ISM bands and amateur radio bands between 0.15MHz and 80MHz 80%AM at 1kHz

TRANSPORT CONDITIONS:

TEMPERATURE -10 Celsius to +50 Celsius
HUMIDITY 30% to 80%
PRESSURES 500hPa to 1,060hPa

If the device has been stored at temperatures outside of the stated operating range, then please allow at least 30 minutes before use to allow the device to acclimatize.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Foreo PEACH, PEACH duo / go / Pro Max Manual

Advertisement

Need help?

Need help?

Do you have a question about the PEACH and is the answer not in the manual?

Questions and answers

Table of Contents