The GasAlertClip Extreme 2 or 3 year gas detector ("the detector")
is a personal safety device that warns when hazardous gas exceeds
factory set alarm setpoints. The detector stores and transmits gas
alarm event data. It is your responsibility to respond properly to the
alarms.
Gases Detected
Oxygen (O
)
2
Carbon monoxide (CO)
Hydrogen sulfide (H
S)
2
Sulfur dioxide (SO
)
2
Safety Information—Read First
a
Warning: Substitution of components may impair Intrinsic Safety.
Warning: Bump test the O
2
its ability to respond to gas by exposing the detector to a gas
concentration that exceeds the alarm setpoints. Manually verify that
the audible and visual alarms are activated.
ƒ Do not activate the detector after the date on the package.
ƒ This product is a gas detector, not a measurement device.
ƒ Perform a self-test each day prior to use.
ƒ Ensure the sensor grill is free of dirt, debris, and is not obstructed.
ƒ Calibrate and/or bump test the detector in a normal atmosphere
(20.9% O
) that is free of hazardous gas.
2
ƒ Periodically test the response of the sensor to gas by exposing the
detector to a target gas concentration that exceeds the low alarm
setpoint. Manually verify that the audible and visual alarms are
activated.
ƒ Periodically calibrate the GasAlertClip Extreme
oxygen (O
) detector.
2
Informations de sécurité—À lire avant tout
a
Avertissement : Le remplacement d'un composant de l'appareil peut
altérer sa sécurité intrinsèque.
Avertissement : Avant chaque utilisation quotidienne, effectuez
un test fonctionnel du capteur O
aux gaz présents, en exposant le détecteur à une concentration de
gaz supérieure aux seuils d'alarme. Vérifiez manuellement que les
alarmes sonore et visuelle sont activées.
ƒ N'activez pas le détecteur après la date figurant sur l'emballage.
ƒ Cet appareil est un détecteur de gaz, pas un instrument de mesure.
ƒ Exécutez un auto-test chaque jour avant toute utilisation.
ƒ Vérifiez que la grille du capteur ne présente ni débris ni poussières,
et qu'elle n'est pas obstruée.
ƒ Étalonnez et/ou effectuez un test fonctionnel du détecteur dans une
atmosphère normale (20,9 % d'oxygène) ne contenant pas de gaz
ƒ Testez régulièrement la réaction du capteur au gaz en exposant le
détecteur à une concentration de gaz supérieure au seuil d'alarme
basse. Vérifiez manuellement que les alarmes sonore et visuelle
sont activées.
ƒ Étalonnez régulièrement le détecteur d'oxygène (O
Extreme.
ƒ
Recycling
c e
This instrument contains a lithium battery. Do not mix with the solid
waste stream. Spent batteries should be disposed of by a qualified
recycler or hazardous materials handler.
About This Instruction Sheet
Title
GasAlertClip Extreme Instruction Sheet
Description
This Instruction Sheet is a reference for the
activation, operation and maintenance of
the GasAlertClip Extreme 2 or 3 year gas
detector.
© 2015 BW Technologies By honeyWell. All righTs reserved.
Percent by volume (%)
Parts per million (ppm)
Parts per million (ppm)
Parts per million (ppm)
sensor before each day's use to confirm
afin de vérifier qu'il réagit bien
2
) GasAlertClip
2
Part Number
50110594-010
Release Date
05-2012
At a Glance
liquid crystal
display(lcd)
Audible
alarm
sensor and
sensor grill
LCD and Elements
C Pushbutton Functions
Activate detector
Press and hold C for 5 seconds
Perform self-test
Press and hold C for 1 second when LCD
displays Test
Calibrate oxygen
Press and hold C for 3 seconds
sensor
Perform auto zero
Press and hold C for 3 seconds
View maximum gas
Press C within 24 hours of a gas alarm
exposure
Transmit data
Press C when LCD displays Prn and
Display gas alarm
Press C during normal operation
setpoints
2 O R 3 YEA R GAS D ETECTO R
50110594-010/05-2012
infrared
download port
led visual
alarms
Alligator
clip
Pushbutton
Self-test status
High and low alarm setpoints
Data transmission
Maximum exposure in alarm
Gas type
Alarm condition
Detector life-remaining indicators
Months-days-hours since last
maximum gas exposure alarm

Advertisement

loading
Need help?

Need help?

Do you have a question about the BW Technologies GasAlertClip Extreme and is the answer not in the manual?

Questions and answers

Summary of Contents for Honeywell BW Technologies GasAlertClip Extreme

  • Page 1 About This Instruction Sheet Title GasAlertClip Extreme Instruction Sheet Description This Instruction Sheet is a reference for the activation, operation and maintenance of the GasAlertClip Extreme 2 or 3 year gas detector. © 2015 BW Technologies By honeyWell. All righTs reserved.
  • Page 2 The LCD displays u to confirm that self-test was successful. Test Detectors may be configured with customer-specified alarm setpoints. displays again 22 hours after performing self-test to indicate that a For more information, contact BW Technologies by Honeywell. new self-test is required. Safety Shutdown Mode Self‑Test Fail...
  • Page 3 Detector Calibration Fail If O detector calibration fails, the detector does not beep or vibrate. Repeat O detector calibration. If the second attempt fails, contact BW Technologies by Honeywell. 50110594-010/08-2015 || gAsAlerTcliP exTreme insTrucTion sheeT WWW.gAsmoniTors.com...
  • Page 4 Contact BW Technologies against harmful interference after activation, assuming 1.5 The obligations set forth in this by Honeywell in a residential installation. minutes of alarm time per day warranty are conditional on: This equipment generates, uses and...