Evergreen
DS Model 6007DS
®
Indoor Blower Motor
Installation Guide
indicates a hazard which, if not avoided, could
result in serious injury or death.
• Read and follow all instructions carefully.
• Disconnect and lock out the main power from the unit being
serviced before installing the Evergreen DS motor. It is also a
good practice to confirm that the power is disconnected with a
voltmeter.
• Do not operate equipment without guards in place.
• Improper installation, adjustment, alteration, service,
maintenance, or use could cause explosion, fire, electrical shock,
or other conditions. Consult a qualified installer, service agency,
or your distributor or branch for information or assistance.
The qualified installer or agency must use the supplied or
recommended parts when installing or servicing this product.
• Installation and service of this Evergreen DS motor should
be performed only by trained service technicians familiar with
these products.
• After installing the Evergreen DS motor, it is the responsibility
of the installing technician to verify the HVAC system matches
the manufacturer's requirements for proper operation, capacity,
efficiency and safety.
This installation guide covers the Evergreen DS indoor blower motor model 6007DS.
Page 1
Application Notes
Page 2
Electrical Connections Pre-Installation Notes; Mechanical Installation
Page 3
Mechanical Installation (Cont.)
Pages 4 & 5 Electrical Connections
Page 6
Start-Up and Commissioning; Electrical Operation
Page 7
Electrical Operation (Cont.)
Page 8
Diagnostics; Changing Rotation
Page 9
Specifications; Technical Support
APPLICATION NOTES
1.
The Evergreen DS motor is designed to replace direct drive, dual shaft Permanent Split
Capacitor (PSC) induction motors found in HVAC indoor blower motor applications with
forward curved (squirrel cage) blower wheels.
NOTE: The Evergreen DS motor is not designed to replace Electronically Commutated
Motors (ECM) including constant torque or constant airflow (variable speed) motors. It is
also not designed for outdoor applications. To find an Evergreen motor for any application for
which the Evergreen DS motor is not designed, please visit ECMMadeEasy.com.
2.
The Evergreen DS motor is pre-programmed. There is no programming necessary at the
time of installation.
3.
Confirm that the ratings of the Evergreen DS motor match the ratings of the motor being
replaced. See page 9 for SPECIFICATIONS if needed.
Regal Beloit America, Inc.
1325 Heil Quaker Blvd.
LaVergne, TN 37086
Customer Service: 800 672 6495
thedealertoolbox.com
regalrexnord.com
indicates a hazard which, if not avoided, could
result in minor or moderate personal injury.
• Periodic inspections should be performed. Failure to perform
proper maintenance could result in premature product failure,
in addition to minor or moderate injury.
• This Evergreen DS motor should be installed in accordance
with accepted practices and installation instructions, and in
compliance with all national and local codes.
©2021, 2022 Regal Rexnord Corporation, All Rights Reserved. MCIM22028E • Form# G0128E
F O R M
G0128E
Revised
June 2022
1
Need help?
Do you have a question about the genteq Evergreen 6007DS and is the answer not in the manual?
Questions and answers