  • Page 1 IN S TA LLATIO N M A NUA L VGREEN EVO® VARIABLE SPEED MOTOR I N S T A L L A T I O N M A N U A L A N D U S E R G U I D E...
  • Page 2: Table Of Contents

    VGREEN EVO® VARIABLE SPEED MOTOR INSTALLATION MANUAL AND USER GUIDE Safety is emphasized throughout this Installation Manual and User Guide. These are safety alert symbols and signal words. They alert the user to potential personal injury hazards. Obey all safety messages to avoid possible injury or death or damage to equipment and other property.
  • Page 3: Introduction

    TABLE OF CONTENTS Continued 4.5.2 Schedule Set B ............... 12 4.5.3 Schedule Set A and B Programming ........14 4.5.4 Schedule Set C (Water Feature Mode) ........15 4.5.5 Schedule Set D (Century Connect™ Automation Mode) ..16-22 PRIMING ....................23 FREEZE PROTECTION ................23 CARE AND MAINTENANCE ..............23 FAULT STATUS, MANUAL RESTART AND POWER OUTAGES ..24...
  • Page 4: Quick Start Instruction

    2.0 QUICK START INSTRUCTION NOTICE: If the VGreen Evo motor is powered off for any reason, at least 60 ® seconds must pass before power is reapplied. Failure to provide an adequate delay could result in damage to the motor. When power is applied to the VGreen Evo motor for the first time it will automatically run the programmed default schedule.
  • Page 5: Operating The Vgreen Evo Motor

    4.0 OPERATING THE VGREEN EVO MOTOR ® The VGreen Evo motor is equipped with 5 different modes that can all be reached ® by a series of button presses on the user interface as outlined in sections 4.1 through 4.5. OVERRIDE MODE PAUSE...
  • Page 6: Operating Mode

    4.1 OPERATING MODE Operating Mode will automatically start once power is applied to the motor and will run the preset or user defined schedule. To turn the motor off, power must be disconnected. The below illustrations show the different scenarios possible during Operating Mode: While the power...
  • Page 7: Override Mode

    4.2 OVERRIDE MODE The VGreen Evo motor is equipped with an Override Mode, which can be ® engaged to temporarily run at maximum speed, which is 3450 RPM if the motor is currently operating at less than 3450 RPM. If the motor is operating at 3450 RPM there will be no change in motor speed.
  • Page 8: Pause Mode

    4.3 PAUSE MODE The VGreen Evo motor is equipped with a Pause Mode that will allow the ® user to temporarily stop the VGreen Evo motor for maintenance work without disrupting the 24 hour schedule (i.e., for backwashing the filter). If the VGreen Evo motor is currently running, the user can follow the below illustrations to operate Pause...
  • Page 9: Schedule Check Mode

    4.4 SCHEDULE CHECK MODE The VGreen Evo motor is equipped with a Schedule Check Mode that will ® allow the user to check which of the 8 available schedules the motor is currently operating. The user can follow the below illustrations to operate Schedule Check Mode: PRESS 3 Times...
  • Page 10: Schedule Set Mode

    4.5 SCHEDULE SET MODE The VGreen Evo motor is equipped with four sets of schedules: Schedule Set A ® and Schedule Set B, are energy efficient schedules designed for use with on/off timer and no controller applications. For instructions on programming the motor for Schedule Set A &...
  • Page 11 4.5.1 SCHEDULE SET A - CONTINUED Dip switch positions set to: #3 OFF , #4 OFF . CTS-2 SCHEDULE SET A 24 HOURS TIME HOURS HOURS HOURS HOURS HOURS 8-10 10-12 12-18 18-24 1750 RPM 1150 RPM 0 RPM 1850 RPM 1250 RPM 0 RPM 1750 RPM...
  • Page 12: Schedule Set B

    4.5.2 SCHEDULE SET B The 8 pre-programmed operating schedules for Schedule Set B: Compliant with California Code of Regulations, Title 20, Section 1605.3 (g) (6) and Title 21 of the Official Compilation of Codes, Rules and Regulations of the State of New York, Section 509.23.
  • Page 13 4.5.2 SCHEDULE SET B - CONTINUED Dip switch positions set to: #3 ON, #4 OFF . CTS-2 SCHEDULE SET B: CALIFORNIA AND NEW YORK COMPLIANT SCHEDULES 24 HOURS TIME HOURS HOURS HOURS HOURS HOURS 8-10 10-12 12-18 18-24 2250 RPM 1550 RPM 0 RPM 2150 RPM...
  • Page 14: Schedule Set A And B Programming

    4.5.3 SCHEDULE SET A AND B PROGRAMING Once the dip switches are in the correct position, cycle power to the motor to enter the correct Schedule Set. The user can then select which of the 8 pre-programmed operating schedules they would like the VGreen Evo motor ®...
  • Page 15: Schedule Set C Water Feature Mode

    NOTE: The motor start time begins when power is initially applied to the motor. If the user changes the schedule and does not cycle power to the motor, the start time of the new schedule will remain the same as the previous schedule.
  • Page 16: Schedule Set D Century Connectâ„¢ Automation Mode

    4.5.4 SCHEDULE SET C WATER FEATURE MODE - CONTINUED After pressing the button, the motor will immediately change speed. The button press can be repeated as many times as desired. The maximum reachable speed is 3000 RPM. The motor will not change with an additional short PRESS of the button once 3000 RPM has been reached.
  • Page 17: Automation System

    4.5.5 SCHEDULE SET D CENTURY CONNECT™ AUTOMATION MODE - CONT. Compatible Systems: Check our website for additional compatible automation systems. AUTOMATION AUTOMATION MANUFACTURER MANUFACTURER SYSTEM SYSTEM Hayward OmniLogic Jandy / Fluidra iAqualink* 3.1 ® ® Jandy / Fluidra Aqualink* RS Hayward ProLogic ®...
  • Page 18: Wiring Configuration

    4.5.5 SCHEDULE SET D CENTURY CONNECT™ AUTOMATION MODE - CONT. Step 2 Continued The configuration of wires depends on the automation system selected. The following wiring diagrams show wire orders for the corresponding automation system: AUTOMATION WIRING CONFIGURATION SYSTEM Hayward ®...
  • Page 19 4.5.5 SCHEDULE SET D CENTURY CONNECT™ AUTOMATION MODE - CONT. Step 3. The system is now connected! Simply re-apply power to the automation system and VGreen Evo motor, and ® allow the system to establish connection with Century Connect Automation Mode.  If present, the system will begin operating based on existing schedules programmed in the automation system. ...
  • Page 20 4.5.5 SCHEDULE SET D CENTURY CONNECT™ AUTOMATION MODE - CONT. Step 3. The light on the VGreen Evo motor will now blink back the selected number ® and then turn off. = CURRENT ∕ ∕ 3 sec ADDRESS # Once the motor has been addressed, please refer to the automation user manual for automation programing steps.
  • Page 21 4.5.5 SCHEDULE SET D CENTURY CONNECT™ AUTOMATION MODE - CONT. Service Mode Button Control For Pentair * EasyTouch * and Intellitouch ® ® ® Automation Systems While connected to an automation system in Schedule Set D, the light on your VGreen Evo motor will be continuously lit.
  • Page 22 4.5.5 SCHEDULE SET D CENTURY CONNECT™ AUTOMATION MODE - CONT. Troubleshooting Century Connect™ Automation Mode SYMPTOM POSSIBLE CAUSES POTENTIAL SOLUTIONS The motor and automation system should both be power cycled after Utilizing the setup is complete. This should allow Hayward ®...
  • Page 23: Priming

    5.0 PRIMING The VGreen Evo motor will always run the priming sequence when starting from ® the stopped position, except when a schedule is selected that does not include a priming sequence. The prime setting is 3450 RPM for 3 minutes. 6.0 FREEZE PROTECTION In the event that the outside air temperature drops below 39°F , the VGreen Evo motor will automatically turn on and circulate the pool water, except when a...
  • Page 24: Fault Status, Manual Restart And Power Outages

    8.0 FAULT STATUS, MANUAL RESTART AND POWER OUTAGES The table below illustrates possible faults that can occur with the VGreen Evo ® motor. If the VGreen Evo motor does not restart automatically, disconnect power to the motor for approximately 3 minutes, and then reapply power to the motor. If this does not correct the situation, contact your local pool service professional.
  • Page 25: Dip Switch Configuration - Quick Start Reference

    9.0 DIP SWITCH CONFIGURATION - QUICK START REFERENCE DESIRED FUNCTIONALITY DIP SWITCH POSITION Schedule Set A: 8 pre-programmed operating schedules for the user to select from. Details can be found in Section 4.51. Dip Switch #3 OFF CTS-2 Dip Switch #4 OFF Schedule Set B: 8 pre-programmed operating schedules compliant with the California Energy...
  • Page 26: Troubleshooting Guide

    10.0 TROUBLESHOOTING GUIDE POSSIBLE SYMPTOM POTENTIAL SOLUTIONS CAUSES Mains voltage is not Replace fuse, reset breaker/GFI. present Tighten mains wire connections. VGREEN ® VGreen Evo motor Check if the VGreen Evo motor can MOTOR shaft is locked be rotated by hand and remove any FAILS TO blockage.
  • Page 27 INSTALLATION NOTES PAGE...
  • Page 28 JEP-R – FLUIDRA, S.A.; Pentair, Easytouch, Intellitouch and Intelliconnect – Pentair, Inc. Regal Rexnord, Century, Century Connect and VGreen Evo are trademarks of Regal Rexnord Corporation or one of its affiliated companies. **“Regal Rexnord” is not indicative of legal entity. Refer to product purchase documentation for the applicable legal entity.