K E E P T HIS OPE R AT ION M A N U A L
FOR FU T U R E R E FE R E N CE
M
A N U A L
OP E R AT ING MA NUA L
P/N 9360873064

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RCW-12 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fuji Electric RCW-12 Series

  • Page 1 OP E R AT ING MA NUA L PE R AT IN G A N U A L A IR CON DIT ION E R CA S S E T T E T Y PE Indoor U nit R CW -12 S E R IE S R CW -12R S E R IE S...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ........1 SWING OPERATION ..........10 FEATURES AND FUNCTIONS ......2 ENERGY SAVE OPERATION ....... 11 NAME OF PARTS ........... 3 MANUAL AUTO OPERATION ......11 PREPARATION ............5 CLEANING AND CARE ........12 OPERATION ............6 TROUBLESHOOTING ..........
  • Page 3: Features And Functions

    FEATURES AND FUNCTIONS AUTOMATIC OPERATION G COOLING MODEL Merely press the START/STOP button, and the unit will begin automatic operation in the Cooling or Dry mode as appropriate, in accordance with the thermostat setting and the actual temperature of the room. G HEAT &...
  • Page 4: Name Of Parts

    NAME OF PARTS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Fig. 1 Fig. 2 SWING TIMER OPERATION MANUAL AUTO Fig. 3 Fig. 4 SLEEP TIMER CLOCK AUTO COOL CLOCK TIMER SLEEP MASTER CONTROL TEMP TIME...
  • Page 5 Fig. 1 Indoor Unit Fig. 4 Remote Control Unit 1 Air Filter C SLEEP Button 2 Horizontal Louvers D MASTER CONTROL Button E SET TEMP./SET TIME Buttons ( 3 Indicator Lamps (Fig. 2) F Signal Transmitter 4 SWING Indicator Lamp (orange) G TIMER Button Lights during use of the SWING.
  • Page 6: Preparation

    PREPARATION CAUTION! Load Batteries (R03/LR03 × 4) G Take care to prevent infants from accidentally swallowing batteries. Open the battery compartment lid. G When not using the remote control unit 1 Slide the battery compartment lid until it stops. for an extended period, remove the 2 While strongly gripping the portion on each side of the battery com- batteries to avoid possible leakage and partment lid that has a rough surface, slide the lid until it comes com-...
  • Page 7: Operation

    OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To Select Mode Operation Press the START/STOP button. SLEEP TIMER The indoor unit’s OPERATION indicator lamp (red) will light. The air conditioner will start operating. Press the MASTER CONTROL button to select the de- COOL sired mode.
  • Page 8 OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). About Mode Operation AUTO: COOLING MODEL G When the room temperature is 2 °C higher than the set temperature, the Cooling Operation mode will switch between Cooling and Drying.
  • Page 9: Timer Operation

    TIMER OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Before using the timer function, be sure that the remote control unit is set to the correct current time (See page 5). To Use the ON timer or OFF timer SLEEP TIMER Press the START/STOP button...
  • Page 10: Sleep Timer Operation

    TIMER OPERATION About the PROGRAM timer About the ON timer G The PROGRAM timer allows you to integrate OFF timer G The timer function is designed to bring your room to a and ON timer operations in a single sequence. The se- comfortable temperature by the set time;...
  • Page 11: Adjusting The Direction Of Air Circulation

    ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Begin air conditioner operation before performing this procedure. Vertical Air Direction Adjustment SWING SWING Press the AIR FLOW DIRECTION SET button. AIR FLOW DIRECTION Each time the button is pressed, the air direction range will change as follows:...
  • Page 12: Energy Save Operation

    ENERGY SAVE OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). The air conditioner can be operated while keeping energy consumption costs down. How To Use the ENERGY SAVE OPERATION SWING SWING Press the START/STOP button AIR FLOW DIRECTION (if the unit is already operating, proceed to step 2).
  • Page 13: Cleaning And Care

    CLEANING AND CARE G Before cleaning the unit, be sure to stop the unit and disconnect the power supply. CAUTION! G Turn off the electrical breaker. G A fan operates at high speed inside the unit, and personal injury could result. Cleaning the Air Filter 1.
  • Page 14: Troubleshooting

    TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec- WARNING! trical breaker, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
  • Page 15 TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Items to check Symptom See Page G Has there been a power failure? CHECK ONCE Doesn’t operate at all: — MORE G Has a fuse blown out, or a circuit breaker been tripped? G Is the timer operating? 8 to 9 G Is the air filter dirty?
  • Page 16: Operating Tips

    OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Operation and Performance *Heating Performance *Microcomputer-controlled Automatic Defrosting G This air conditioner operates on the heat-pump principle, G When using the Heating mode under conditions of low absorbing heat from outdoor air and transferring that heat outdoor temperature and high humidity, frost may form indoors.
  • Page 17: Specifications

    SPECIFICATIONS MODEL INDOOR UNIT RCW-12 SERIES RCW-14 SERIES RCW-18 SERIES RCW-12R SERIES RCW-14R SERIES RCW-18R SERIES OUTDOOR UNIT ROC-12 SERIES ROC-14 SERIES ROC-18 SERIES ROC-12R SERIES ROC-14R SERIES ROC-18R SERIES TYPE COOLING MODEL HEAT&COOL MODEL POWER 1~220-240 V 50 Hz...
  • Page 18 SPECIFICATIONS MODEL INDOOR UNIT RCW-12 SERIES RCW-14 SERIES RCW-18 SERIES RCW-12R SERIES RCW-14R SERIES RCW-18R SERIES OUTDOOR UNIT RO-12C SERIES RO-14C SERIES RO-18C SERIES RO-12H SERIES RO-14H SERIES RO-18H SERIES TYPE COOLING MODEL HEAT&COOL MODEL POWER 1~220-240 V 50 Hz...

Table of Contents