HP 330834-B21 - StorageWorks Ultrium 460 Tape Library Drive Module Getting Started Manual page 48

Internal model
Hide thumbs Also See for 330834-B21 - StorageWorks Ultrium 460 Tape Library Drive Module:
Table of Contents

Advertisement

LED
Sequence
or
44
Cause
Ready is FLASHING fast.
The drive is
downloading firmware.
Ready is OFF, others are
ON.
Firmware is being
reprogrammed.
Clean is FLASHING.
The drive requires
cleaning.
Ready is FLASHING and
Clean is ON.
Cleaning is in progress.
Tape Error is FLASHING.
The drive believes the
current tape or the tape
just ejected is faulty.
The tape is ejected
immediately and Tape
Error is FLASHING, or
Drive Error FLASHES on
unloading tape.
The tape cartridge
memory (CM) may be
faulty.
Drive Error FLASHING.
The drive mechanism
has detected an error.
Action required
None.
Do not reset or power cycle the drive.
None.
Do not reset or power cycle the drive.
Load the Ultrium cleaning cartridge. See page 28 for
supported cartridges and instructions.
If the Clean LED is still flashing when you load a new
or known data cartridge after cleaning, call for
service.
None. The cleaning cartridge will eject on
completion.
The cleaning cycle can take up to 5 minutes to
complete.
Unload the tape cartridge. Make sure that you are
using the correct format cartridge; an Ultrium data
cartridge or Ultrium Universal cleaning cartridge.
(See page 28.)
Reload the cartridge. If the Tape Error LED still flashes
or starts flashing during the next backup, load a new
or known, good cartridge.
If the Tape Error LED is now off, discard the 'suspect'
tape cartridge. If it is still on, call for service.
Write-protect the cartridge by sliding the red switch
on the tape cartridge. The tape can be loaded and
the data read. Once the data is recovered, the
cartridge must be discarded.
Load a new cartridge. If the error persists, power
cycle or reset the drive.
If the Drive Error LED remains on, call for service.