User Manual MS Series moisture analyzer Preface Users should read this Manual carefully, follow the instructions and procedures, and beware of all the cautions when using this instrument. Service In order to guarantee this equipment works safely and efficiently, it must receive regular maintenance. In case of any faults, do not try to repair it yourself.
Page 3
1. OVERVIEW Safety precautions To ensure the safe and reliable use of the moisture analyzer, please observe the following precautions: This instrument is suitable for the determination of the moisture content of the sample. When using a moisture analyzer, any improper operation can result in personal injury and damage to the instrument.
Use disclaimer The settings of the MMB series moisture meter must be carefully selected according to the user's needs and the characteristics of the sample to be analyzed. This device operates at high temperatures and, in some cases, with samples that may be hazardous, so its use requires adequate knowledge of the technique and its associated risks.
Page 5
Component installation ( 1 ) Place the windshield. ( 2 ) Place the sample tray (3)Place the sample tray flat on holder. the sample tray holder. Connect the power supply Plug the correct end of the supplied power cord into the power input slot on the back of the moisture analyzer and connect the other end to the power outlet.
Page 6
3.2 Display Logos descriptions: Weight(grams) High precision Moisture content % Medium precision Automatic mode test g weightlessness Low accuracy accuracy 100 ºC Temperature (in Hand Manual customization Celsius) 10:00 Time setting: minutes fast and seconds Operation mode Auto standard Heating method Time slow...
Page 7
Start/stop Press Return function after testing Test start/stop On/Off Press On/off 4. Parameter settings Standby mode: When the moisture analyzer is connected to the AC power supply, it is in the standby state. 4.1 Moisture meter use Select the appropriate working mode test (set or select according to 4.2) ...
Page 8
Parameter setting example: Storage group: Group 8; test temperature: 120 ° C; control mode: Automatic; Automatic mode accuracy: high precision; temperature control speed: standard Button (command) Step description Display Long press [Set] Enter parameter setting item Weighing area, showing the number and parameters of the currently used group 〖1 〗...
Page 9
Time and manual settings: Time Mode, Set the desired time after selection 〖05:00〗 Short press [Set] Second zone flashing Short press [Print] / [Zero] 〖05:35〗 Set the number of seconds, step value 5 second Short press [Set] Save and enter the sub-settings, the partition flashes Short press [Print] / [Zero] Set the number of seconds, step value 1 minute 〖12:35〗...
Page 10
Button (command) Step description Display Long press [Zero] Display ------” ,Release button 〖100.000g〗 Place a 100g standard weight on the measurement sample tray Short press [Zero] Display 100.000” flicker Then shows 〖100.000g〗 Remove the weight and the calibration is over. 5.
Page 11
6. Test optimization During the heat drying process, the moisture is determined by the weight loss of the sample. The speed and quality during the measurement can be referred to the following parameters. The following parameters can also be determined by several trial experiments to determine the best settings.
Page 12
Another way to determine the weight of a sample is to take advantage of the relationship between sample weight and repeatability result should be ±0.3%, and the table indicates that the sample weight should be at least 2 g. (The following test data is for reference only). 6.4 Sample preparation Samples need to be representative of the test to obtain accurate and reproducible measurements.
Page 13
Toxic Chemicals Substances containing toxic or corrosive ingredients can only be dried in a fume hood. Corrosive substance Substances that generate corrosive gases (such as acidic substances) should be tested with a small amount of material because the vapor they generate can condense on the moisture analyzer components and cause corrosion.
Page 14
7.4 Technical data 8. Use environmental technical parameters Ambient conditions Technical parameters are valid in the following environments: Ambient temperature: 10°C - 30°C; operation is guaranteed in the environment of 5°C to 40°C, and the measurement accuracy of the moisture analyzer is not guaranteed under extreme temperature.