ORIGINAL INSTRUCTIONS AIR CONDITIONER INSTRUCTION MANUAL FCW2600PAP FCW3500PAP SODILOG SAS, 4 RUE CURIE, CS 91617 68016 COLMAR CEDEX FRANCE Made in PRC This instruction manual contains important information and recommendations that we ask you to follow in order to get the best...
1. SAFETY PRECAUTIONS ever use broken or unspecified power cable, power plug and socket. Otherwise it will cause accidents such as electric shock, short circuit. ever use the same power socket with other electrical appliances or use too long power cables. Otherwise it will cause fire disaster, electric shock, short circuit, etc ever use fuse with improper capacity or other metal fuses.
Page 4
o not maintain or repair the air conditioner. Otherwise it will cause electric shock and fire disaster. Please contact our authorized service center to send professional maintenance personnel to repair. he place for installation should be capable of load-bearing. If the installation bracket for outdoor unit is broken, do not place air conditioner on it.
Page 5
o not touch the aluminum parts of indoor unit or outdoor unit of air conditioner. Sharp aluminum sheet may cause personnel injury. ubing for the drain hose should ensure the good drainage. In case of bad tubing, the water will penetrate into the room and moisten the items in the room. requently ventilate.
2. NAMES AND FUNCTIONS OF EACH PARTS Because there are many models, features and appearance will vary, we only introduce the following. NOTE: The picture shows the structure diagram, rather than the product.
3. DISPLAY ICON Running indicator Timer indicator Sleeping indicator Cooling indicator Heating indicator Dehumidifying indicator Ventilation run icon Auto indication icon Low wind run icon Stroke run icon The high wind run icon Strong run icon Digital display tube icon Electric heating run icon Above figure shows all indications for the purpose of the explanation but practically only the partinent parts are indicated.
4. TECHNICAL SPECIFICATIONS Refer to the technical label located on the outdoor unit. 5. INSTRUCTIONS FOR SERVICING 1. Qualification requirement for installation and maintenance man All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry.
Page 9
- Be aware that refrigerants might not contain an odour. - The installation of pipe-work shall be kept to a minimum. - The pipe-work shall be protected from physical damage and shall not be installed in an unventilated space. - The compliance with national gas regulations shall be observed; - The mechanical connections made shall be accessible for maintenance purposes;...
Page 10
If in doubt consult the manufacturer's technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: - The charge size is in accordance with the room size within which the refrigerant containing parts are installed; - The ventilation machinery and outlets are operating adequately and are not obstructed;...
Page 11
edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans. 6. Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks.
Page 12
Prior to recharging the system, it shall be pressure-tested with the appropriate purging gas. The system shall be leak-tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site. 10.
cylinder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers.
Please check if the power supply for air conditioner conforms to the requirements of national standards: AC 50Hz 220V-240±10%, lt is the basic requirement for the safe and long-term use of your air conditioner. When installing or handling the air conditioner, no other gases except for specified refrigerant is allowed to mix in the refrigerant pipeline system.
Page 15
Piping Length Cooling Maximum Height Maximum Height Additional for Adding of Capacity Piping Length(m) Difference(m) Refrigerant (g/m) Refrigerant(m) 1P/1.5P 2P/3P Recommended cable specification...
Page 16
Cooling Capacity Suggested that type 1.5P/2P ≥1.5mm² ≥2.5mm² Indoor power cord H05VV-F ≥1.0mm² Indoor and outdoor ≥1.0mm² ≥1.5mm² ≥2.5mm² H07RN power cord Indoor and outdoor H05RN ≥0.75mm² ≥0.75mm² ≥0.75mm² signal line NOTE: This is the schematic diagram and not the product appearance drawing. ...
Page 17
NOTE: Drain hose of indoor unit can only be drawn out from its own side. 2. Fix the indoor unit on the wall-hung board. Installation of outdoor unit Installation and fixation Fix the mounting bracket (to be purchased additionally) on the wall and fix the outdoor unit firmly on the mounting bracket and remain level.
Page 18
Warning! The complete measures must be taken for grounding connection. When the electric wire is suffering the external force, it should ensure the core wires (yellow/green lines) of grounding wire to be stretched after other current-conductor core wires. Piping Connection ...
Page 19
4. During exhausting air, press the pin on the service port of three-way valve with hex wrench for 3 seconds and then release for 1 minute. Open the two-way valve and then close. Repeat the above procedure for 3 times to exhaust air. 5.
Inspection after installation Inspection Items Problems caused by improper installation Check if installation is firm Machine may be fell down, vibrated or made noise Check if there is any leakage It may cause insufficiency of cooling (heating) capacity Check if the heat insulation of machine is Condensation or water drop may appear sufficient Check if the drainage is smooth...
Page 21
Combination key: Quiet+Timer=Child lock Sleep+Display= Sleep+Turbo=TA/TS Quiet+ECO=Electric heating ECO+Timer=Health Please refer to the detailed instructions. The picture of the remote control is for reference only, please refer to the actual product.
Page 22
Button Function On/Off control, for the air conditioning turned on or off. Pressing ECO to switch cyclically according to“ECO--STOP ECO--ECO" Cycle mode when this button is pressed as follows: AUTO--COOL--DRY--HEAT- -FAN--AUTO (Temperature/Time) △/▽ Press "△" once to set the temperature to rise by 1℃, press "▽"once to decrease the temperature by 1℃.
Page 23
Cleaning Only under remoter controller condition of power off, can it transmit “ auto clean" signal when this button is pressed to power on. The remote control and indoor unit will display CL. Press CLEAN or ON/OFF again to exit the automatic cleaning function. In automatic cleaning mode, the air conditioner will run for 10 to 15 minutes and then shut down automatically.
For some model, each time when insert the batteries in the remote controller for the first time, you can set the Cooling only or Heating pump control type. As soon as you insert the batteries, turn off the remote controller, and operate as below. 1.
Page 25
Before the using season Check if the air inlet and air outlet of indoor unit and outdoor unit are blocked. The protective cover of outdoor unit must be removed. Check if the installation base is corrosive or rusted. Check if the power cable and grounding wire are in normal condition. Check if the drain hose is bent, end is lifted, or is blocked.
10. FAULT ANALYSIS FAULT ANALYSIS After shutting down, the air conditioner If the user restarts the air conditioner when it cannot restart immediately. is just stopped, the 3-minute protective timer of air conditioner will be automatically activated and the air conditioner will be restarted 3 minutes later.
In case of following situations, please stop operation immediately, shut off power, and contact our dealers or authorized service center. The fuse always bum out and electric switch is always disconnected. Electric wire is abnormally heated or the wire insulation is broken. Other abnormal status.
SODILOG SAS 4 RUE CURIE, CS 91617 68016 COLMAR CEDEX FRANCE Declares that the machines: AIR CONDITIONER Model: FCW2600PAP-A, FCW3500PAP-A Serial No.: 20250115866-20250116465 /20250118704- 20250118970 20250116466-20250117465 / 20250118971- 20250119306 Complies with the provisions of the Directive: COMMISSION REGULATION (EU) No 206/2012...
13 . WARRANTY The manufacturer guarantees the product against defects in material and workmanship for a period of 5 years from the date of the original purchase. It can be extended by one year if the user subscribes to website of myswap. The warranty only applies if the product is for household use. The warranty does not cover breakdowns due to normal wear and tear.
1 4 . PRODUCT FAILURE WHAT TO DO IF MY MACHINE BREAKS DOWN? If you bought your product in a store: • Make sure that your machine is complete with all accessories supplied, and clean! If this is not the case, the repairer will refuse the machine. •...
1 5 . WARRANTY EXCLUSIONS THE WARRANTY DOES NOT COVER: • Start-up and setting up of the product. • Damage resulting from normal wear and tear of the product. • Damage resulting from improper use of the product. • Damage resulting from assembly or start-up not in accordance with the user manual. •...
Page 32
SODILOG SAS 4 RUE CURIE, CS 91617 68016 COLMAR CEDEX FRANCE Made in PRC...