fluidra ZODIAC Ei2 iQ Series User Manual

Salt chlorinator for swimming pools
Hide thumbs Also See for ZODIAC Ei2 iQ Series:
Table of Contents

Advertisement

Quick Links

m
3
8.000h
Ei
iQ
2
40-110
pH
ORP
g/L
ºC
USER MANUAL
E N
Models
Salt chlorinator for swimming pools
Ei2 12 / Ei2 pH EVO 12
Ei2 20 / Ei2 pH EVO 20
Ei2 25 / Ei2 pH EVO 25
Ver.20250409

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZODIAC Ei2 iQ Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for fluidra ZODIAC Ei2 iQ Series

  • Page 1 8.000h 40-110 ºC USER MANUAL Models Salt chlorinator for swimming pools Ei2 12 / Ei2 pH EVO 12 Ei2 20 / Ei2 pH EVO 20 Ei2 25 / Ei2 pH EVO 25 Ver.20250409...
  • Page 4: Table Of Contents

    CONTENTS ① General Informati on 1.1 | General Characteristics 1.2 | Safety Warnings and Recommendations 1.3 | Contents 1.4 | Dimensions 1.5 | Technical Description ② Installati on of the Equipment 2.1 I Wall-Mounted Equipment 2.2 | Information on Connections 2.3 | Installation Diagram 2.4 | Electrolysis Cell Installation 2.5 | Connecting the Electrolysis Cell...
  • Page 5 5.15 | Info Mode 5.16 | Biopool ⑥ Info Menu, Calibrati on and Alarms 6.1 | Calibrating the pH Sensor 6.2 | Calibrating the mV (ORP) Sensor 6.3 | Calibrating the Salinity (g/L) 6.4 | Calibrating the Temperature 6.5 | Alarm Information ⑦...
  • Page 6: ① General Informati On

    PLEASE NOTE: This instruction manual contains essential information about the safety measures to adopt during the installation and commissioning. Hence, it is essential, that both the installer and the user read these instructions before installing and using the equipment. Keep this manual for future reference about operating this device. Treatment of electrical and electronic devices at the end of their useful life (applicable in the EU only).
  • Page 7: Safety Warnings And Recommendations

    1.2 | Safety Warnings and Recommendations Installation and manipulation should only be performed by suitably qualified technicians. Applicable standards for prevention of accidents and for electrical installations must be respected. During installation, bear in mind that electrically disconnecting the equipment requires a switch or circuit breaker according to standards IEC 60947-1 and IEC 60947-3 which ensures an omnipolar cut-off, directly connected to the power supply terminals and with a contact separation in all poles, providing total disconnection under overvoltage category III conditions, in an area that fulfils the safety requirements of the site.
  • Page 8: Contents

    1.3 | Contents Quick Start Equipment Cell Guide Temperature Installation Flow switch Wall mount Ei2 iQ 12 Ei2 iQ 20 Ei2 iQ 25 Equipment Cell Quick Start Guide pH kit Temperature Injector sensor ORP kit Flow switch Installation (optional) Wall mount sensor Ei2 iQ 12 pH evo Ei2 iQ 20 pH evo...
  • Page 9: Technical Description

    1.5 | Technical Description Control unit MODEL Description Operating voltage 230 Vac 50/60 Hz. Consumption (A AC) 0.45 A 0.65 A 0.85 A Fuse (5x20 mm) 3.15 A 3.15 A Output (A DC) 2.5 A 4.0 A 5.0 A Production (g Cl2/h) 10–12 16–20 20–25...
  • Page 10: ② Installati On Of The Equipment

    ② Installati on of the Equipment 2.1 I Wall-Mounted Equipment 5 x 35 mm 7 x 35 mm The control unit must always be installed in a VERTICAL position on a smooth wall surface. It should also be far enough away from the cell to prevent it from being accidentally splashed with water. The cell must always be installed in a VERTICAL position above the ground, as shown on the recommended installation diagram.
  • Page 11: Installation Diagram

    2.3 | Installation Diagram Equipment Electrical control panel pH pump Cell + Temperature pH injector Flow switch ON/OFF ORP sensor switch Flow switch pH sensor Cell + 230 Vac supply Temperature Filter Other equipment pump Injector Outlet Inlet minus N.B.: This layout shows an installation for an Ei2 evo model including all the options. The layout may vary according to the particular model.
  • Page 12: Connecting The Electrolysis Cell

    2.5 | Connecting the Electrolysis Cell Interconnect the electrolysis cell and the control unit according to the following diagrams. Due to the relatively high current flowing through the electrolysis cell wires, under no circumstances should the length or cross-section of the wires be changed without first consulting your authorised distributor. MOD.
  • Page 13 - Installing the NTC temperature probe ① Ⓐ Ⓑ Ⓒ ② ③ ④ Ⓒ Ⓐ Ⓐ Ⓑ Ⓑ ⑤ ⑥ ⑦ Ⓐ Ⓐ Ⓒ Ⓒ Ⓑ Temperature sensor Installed Ⓐ + Ⓑ + Ⓒ =...
  • Page 14: Initial Start-Up

    ③ User Interface 3.1 | Description of the Cover Information on active functions of the equipment: pH, % production, ORP, salinity (g/L) and temperature 2) Bluetooth indicator (pairing with Fluidra Pool) 3) Wi-Fi status indicator 4) Alarm indicator...
  • Page 15: Starting Sequence, Turning Wi-Fi/Bt And The Ph/Orp Drivers On/Off

    3.2 | Starting Sequence, Turning Wi-Fi/BT and the pH/ORP Drivers On/Off Wi-Fi/BT ON pH & ORP OFF Power On Information on model and active functions Wi-Fi/BT ON pH OFF ORP OFF Firmware (FW) IOT settings (Wi-Fi ON by default OFF by default OFF by default version &...
  • Page 16: Home Screen Information

    3.4 | Home Screen Information By default, the Home screen cycles through the pool water’s main values (%, pH, mV), allowing its condition to be checked at a glance. Temperature and salinity g/L are shown by default on a second plane (factory setting: INF OFF). The user may choose to view these on the Home screen by activating INF ON in the Confi guration menu.
  • Page 17: ④ Navigati Ng And Changing Producti On (%), Ph And Mv (Orp) Set Points

    ④ Navigati ng and Changing Producti on (%), pH and mV (ORP) Set Points 4.1 | Changing Production (%) Set Point Ei2 iQ evo pH Home (production % + pH + mV) To change the production set point, follow the steps below. •...
  • Page 18: Changing Ph & Mv (Orp) Set Points

    4.2 | Changing pH & mV (ORP) Set Points Ei2 iQ evo pH Home (production % + pH + mV) To change the pH/ORP set point, follow the steps below. Changing the pH set point • Access change mode: press the key;...
  • Page 19: ⑤ Confi Gurati On Menu

    ⑤ Confi gurati on Menu All equipment settings can be reviewed and changed in the confi guration menu. To access the confi guration menu, press the “Info” key on the equipment’s home screen for 5 seconds until “CFG” is shown on the screen, and release the key. Ei2 iQ pH EVO Home (production % + pH + mV) Confi guration Alarms...
  • Page 20: Fw Version And Confi Guration Reset

    5.1 | FW Version and Confi guration Reset Home SOF: shows the equipment’s fi rmware version. Confi guration reset: The equipment allows all settings to be reset to their default value. To do so, while the fi rmware version information is being shown press the “INFO” key followed by the “+”...
  • Page 21: Polarity Inversion

    5.3 | Polarity Inversion 5 seconds POL: polarity inversion time. Default setting 2h/2h. Polarity inversion enables the removal of lime accumulated on the electrodes. The default inversion time is 2h/2h but is confi gurable (2h/2h, 3h/3h, 4h/4h, 7h/7h and test mode 2min/2min). Set polarity inversion time Change setting 2h - 3h - 4h - 7h - tst...
  • Page 22: Flow Switch Control

    5.5 | Flow Switch Control FS: fl ow switch control. Default setting: ON. 5 seconds When this function is enabled, the equipment will stop chlorine production when the sensor does not detect any fl ow. Current setting If FS is ON and the system does not detect any water fl ow, the equipment displays the FS alarm and electrolysis Change setting ON | OFF...
  • Page 23: Cover

    5.7 | Cover COV: Cover. Default setting: OFF 5 seconds The cover function allows confi guration of a production set point so that this is automatically activated when the pool cover is closed for the winter. This percentage is confi gurable (10–90%). % set Cover set % Current setting...
  • Page 24: Initial Ph Stabilisation

    5.9 | Initial pH Stabilisation INI: initial pH stabilisation. Default setting: 2min. 5 seconds This is the pH reading stabilisation time. After switching on the equipment, a time of 1min/2min/4min can be set to obtain a stable pH reading. N.B.: The pH pump will not dose during the stabilisation period. Current setting Change setting OFF | 1 - 2 - 4 min...
  • Page 25: Internal Chlorine Control

    5.11 | Internal Chlorine Control CLI: internal chlorine control. Default setting: ON (version Ei2 EVO with ORP kit) 5 seconds Depending on the equipment’s ORP reading function, the equipment will activate or deactivate electrolysis to adjust it to the previously confi gured ORP set point. Current setting Change setting ON | OFF 5.12 External chlorine control...
  • Page 26: Temperature Alarm

    5.13 | Temperature Alarm TEM: temperature alarm. Default setting: OFF 5 seconds The equipment allows for the operating temperature range to be confi gured, setting a high and a low temperature value. When the temperature is out of range, the equipment will display an alarm. Current setting Change setting OFF | ON (0–40 ºC)
  • Page 27: Info Mode

    5.15 | Info Mode InF: Info mode. Default setting: OFF 5 seconds With INFO mode OFF, the equipment’s Home screen will only display major values according to the equipment version installed (%, pH and ORP). With INFO mode ON, the equipment will always show 3 variables on the Home screen.
  • Page 28: ⑥ Info Menu, Calibrati On And Alarms

    ⑥ Info Menu, Calibrati on and Alarms Ei2 iQ evo pH Home (production % + pH + mV) Current production % Current pH Current mV (OPR) Current g/L Current temperature Active alarms (PS/pH/ORP/Flow/Salt/ Temp./CLI/CLE) Variables Alarms The “INFO” key is used to navigate between current values. The “CAL”...
  • Page 29: Calibrating The Ph Sensor

    6.1 | Calibrating the pH Sensor Current pH HOME Standard pH calibration Fast pH calibration Reset to factory calibration From the pH calibration menu, the equipment allows standard calibration, fast calibration or resetting the current calibration to factory settings: Standard pH calibration Standard calibration mode allows precise calibration of the sensor using two calibration solutions with pH 7.0 and pH 4.0.
  • Page 30: Calibrating The Mv (Orp) Sensor

    Reset to default calibration values Resetting calibration values to default values deletes any previous calibration (STD or FST) from the equipment. 6.2 | Calibrating the mV (ORP) Sensor HOME Current mV(ORP) Standard mV(ORP) Reset to factory calibration calibration From the mV(ORP) calibration menu, the equipment allows standard calibration or resetting the current calibration to factory settings: Standard mV(ORP) calibration Standard calibration mode allows precise calibration of the sensor using a 470 mV calibration solution.
  • Page 31: Calibrating The Salinity (G/L)

    6.3 | Calibrating the Salinity (g/L) HOME Current salinity (g/L) Standard g/L calibration Reset to factory calibration From the salinity calibration menu, the equipment allows standard calibration or resetting the current calibration to factory settings: Standard salinity (g/L) calibration Salinity (g/L) calibration mode allows routine recalibration to correct small errors in readings. For this you need to know the current salinity of the pool water, which can be read using an external sensor.
  • Page 32: Calibrating The Temperature

    6.4 | Calibrating the Temperature HOME Current temperature Allows units to be changed between ºC and ºF Standard g/L calibration Reset to factory calibration From the temperature calibration menu, the equipment allows standard calibration or resetting the current calibration to factory settings: Standard temperature calibration Temperature calibration mode allows routine recalibration to correct small errors in readings.
  • Page 33: Alarm Information

    6.5 | Alarm Information When the equipment has an active alarm, an alarm signal appears on the Home screen. In addition to this signal, if it is a fl ow alarm (FS or FE) the circle on the Home screen will fl ash. To check the remaining alarms, access the alarm menu.
  • Page 34 - pH high/low alarm Low or high alarms appear if the pH reading is outside the set values. These values cannot be modified. If the high pH alarm appears, the pH pump will be switched off according to the safety values set. Standard mode pH >...
  • Page 35 - Temperature high/low alarm The temperature alarm will appear when temperature values are outside the range set by the user. When the water temperature is very low, the equipment might not reach 100% production due to low conductivity. - Salinity high/low alarm The salinity alarm will appear when salt g/L values are out of range.
  • Page 36: ⑦ Total/Parti Al Resets

    ⑦ Total/Parti al Resets As we have seen in chapters 3.2 and 5.1, the equipment has two types of reset, total and partial. Total reset (3.2): All general parameters plus all Confi g menu settings are reset. Parameter Value pH set 7.20 mV (ORP) set % set...
  • Page 37: ⑧ Pairing With Fluidrapool

    ⑧ Pairing with FluidraPool 1) Download and install 2) Create a user account and set up a new installation. the FLUIDRA POOL app. Home INFO INFO 3) Enter the pairing mode from the Home screen 4) Press “Add equipment” and follow the (press "+”...
  • Page 38: ⑨ Maintenance

    ⑨ Maintenance 9.1 | Electrolysis Cell Maintenance The cell should be maintained in suitable condition to ensure long-lasting operation. The saline electrolysis system has an automatic electrode cleaning system to avoid the build up of limescale on the electrodes; therefore, it should not be neces- sary to clean them.
  • Page 39: Ph Pump Maintenance (2-6-Month Maintenance)

    9.3 | pH Pump Maintenance (2–6-Month Maintenance) CHECK TUBING AND ROTOR pHminus (ACID): 2–12 MONTHS EXTREMELY RECOMMENDED CORROSIVE ATMOSPHERE CORROSIVE CORROSIVE ATMOSPHERE ATMOSPHERE 0–1 m SULPHURIC pHminus pHminus pHminus Check Check Check 2–3 3–6 6–12 months months months...
  • Page 40: ⑩ Troubleshooti Ng

    ⑩ Troubleshooti ng Message Solution Flow alarm The fl ow alarm will appear if the cell is not completely fl ooded (electrode gas sensor), or if there is no water fl ow (fl ow switch sensor). - Gas sensor (FE) •...
  • Page 41: ⑪ Technical Specifi Cati Ons And Features

    ⑪ Technical Specifi cati ons and Features Standard operating voltage Control system 230V AC, 50/60 Hz. - Microprocessor Cable: 3 x 1.0 mm2, length 2 m. - Touch control buttons and operational indicator LEDs MOD. 12 0,45 A - I/O control: 3 voltage-free contact inputs for automatic cover status, MOD.
  • Page 42: ⑫ Warranti Es

    ⑫ Warranti es GENERAL CONSIDERATIONS In accordance with these conditions, the seller guarantees that the product covered by this guarantee conforms to its specifi cations at the moment of its delivery. The warranty period of the product is that which is determined by the legal requirements of the country in which the pro- duct was acquired by the consumer.
  • Page 44 Ei2 iQ Made in Spain by I.D. Electroquímica, S.L. AstralPool A Fluidra Brand | www.astralpool.com FLUIDRA S.A. AVDA. ALCALDE BARNILS, 69 08174 SANT CUGAT DEL VALLÈS (BARCELONA)