Advertisement

Quick Links

CC-600
COILPRO™ COIL CLEANER
Operating & Maintenance Manual
Goodway Technologies Corporation
420 West Avenue
Stamford, CT 06902-6384
(203)359-4708
Sales: 1-800-333-7467
Customer Service: 1-800-370-2855
Fax: 1-800-359-9625
E-mail:
goodway@goodway.com
Internet:
www.goodway.com
Copyright 2014 Goodway Technologies Corp., Stamford, CT, U.S.A.
Effective Date: March 23, 2015
Goodway® is a registered trademark of Crossford International
Goodway reserves the right to improve products - contact the factory for the latest configuration and uses

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COILPRO CC-600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Goodway COILPRO CC-600

  • Page 1 Internet: www.goodway.com Copyright 2014 Goodway Technologies Corp., Stamford, CT, U.S.A. Effective Date: March 23, 2015 Goodway® is a registered trademark of Crossford International Goodway reserves the right to improve products - contact the factory for the latest configuration and uses...
  • Page 2: Table Of Contents

    Thank you for purchasing this Goodway CoilPro Coil Cleaner. We appreciate your business and look forward to serving you in the future. As with all Goodway products, you can be assured that the finest quality components and workmanship have gone into this machine.
  • Page 3: Work Area

    IMPORTANT SAFTEY INSTRUCTION Warning! Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fire and/or serious personal injury. SAVE THESE INSTRUCTIONS 1. Work Area:  Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents.
  • Page 4: Specific Safety Rules

     Disconnect the plug from the power source before making any adjustments, changing accessories, or storing the tool. Such preventative safety measures reduce the risk of starting the tool accidentally.  Store idle tools out of reach of children and other untrained persons. Tools are dangerous in the hands of untrained users.
  • Page 5: Safety Checklist

    CAUTION! IF YOU ARE UNSURE ABOUT CHEMICAL COMPATABILITY CALL ™ GOODWAY AT ONCE BEFORE PUTTING CHEMICAL INTO THE COILPRO  Don’t point spray lance at people or animals as this unit discharges a high-pressure stream that may contain chemicals.
  • Page 6: Operating Instructions

    Operating Instructions Assembly The unit may be used with or without the dolly. To attach the dolly, place the dolly against the rear of the unit. Screw attachment bolts on the dolly into the matching holes on the unit. Connect the cord hooks to the dolly crossbar using the hardware provided. For normal use, insert the male quick connect of the pressure hose into the female quick connect on the unit.
  • Page 7: Operational Matrix

    Operational Matrix Coil Pro Settings for the various operational modes: ™ CoilPro Settings Tank 1 Tank 2 Garden Water Chem Liquid Hose Valve Valve Liquid Tank 1 On-Board Water Water Water Only Tank 2 On-Board Water with Water Chemical Tank 1 Chemical Mix Garden Hose Garden...
  • Page 8: Filling The Tanks

    Non-approved chemicals may damage ™ the internal components of the CoilPro and void the warranty. Call Goodway, If unsure 1-800-370-2855. 6. The tanks can be filled to the bottom of the fill spout. Avoid over-filling and spillage, wipe any spills up immediately.
  • Page 9: Normal Coil Cleaning Operation

    Normal Coil Cleaning Operation 1. Make sure the Power Switch is in the “Off” position. 2. See “Operational Matrix” and fill the on-board tanks with appropriate liquids and/or connect a garden hose to the unit. 3. For best results and maximum self-contained operation time, it is advisable to fully prime the pump before normal operation.
  • Page 10: Long Term Storage Preparation

    3. Purge the injector – (NOTE: The pump should be fully primed with water before purging can occur. See Priming the Pump.) Pour 1 gallon 3.785 Liters of clean water in Tank 2, pour 5 gallon 18.9 Liters of clean water into Tank 1 or connect to garden hose.
  • Page 11: Troubleshooting

     Chemical Valve is not  Turn Chemical Valve to ON chemical is sprayed position  Problem with GFCI  Contact Goodway Customer  Electrical short in the GFCI fails to reset Service at (800) 370-2855 unit CC-600 3/1/2014...
  • Page 12: Coilpro™ Faq

    CoilPro™ FAQ ™ 1. How far or high can I clean coils away from the CoilPro unit? ™ The CoilPro comes with a 30’ spray hose. Horizontally, there is really no limit to the distance away from the unit that you can spray. Vertically, for every foot above the ™...
  • Page 13: Specifications

    Specifications Motor Power: 1.3 HP Input Power: Standard: 13 amps, 115 V, 60 Hz AC Optional: 6.5 amps, 230 V, 50 Hz Water Requirements: Maximum 120 PSI Output Water Pressure: 600 PSI Output Water Flow: 1.6 GPM Pump: Positive displacement diaphragm Water Tank: 5 gallons Soap Tank:...
  • Page 14 9651 9651 Top View Chemical Tank Water Tank QDN-0004R 9647 Cap QDN-1504Y 9619 Foaming Nozzle 2509 Grommets 9672 Cord Hook Back Side On/Off Switch Front Side 9605 Water Control 9625 Chemical QDN-FA2 Water 953 Garden Hose Inlet 803 Screen Washer CC-600 3/1/2014...
  • Page 15 (2) 9621 Strainer 9605 (2) 1012 Water Control Hose Clamp (15) 9645 Hose Clamps 9625 Hose to Water Chemical Tank (2) 9608 Bulk Head Fitting 1011 By Pass Hose 802 Water Right Side of Motor Connector 6025 Chemical (2) 9648 Injector Hose Clamp 9604...
  • Page 16 We Are Here to Serve You! For Sales Call: 1-800-333-7467 For Service Call: 1-800-370-2855 Goodway Technologies Corporation manufactures and distributes a complete line of Tube/Pipe Cleaning Systems, Duct Cleaning Systems, Vacuums, Floor Machines, Hi-Pressure Washers and other maintenance related equipment.