Boiler dhw recirculation kit zeus mini - victrix zeus 26 kw (2 pages)
Summary of Contents for Immergas UI DUCT
Page 1
SMART KIT WI-FI UI DUCT UI SP User Manual Instructions and warnings...
Page 2
Thank you for purchasing this product. Before using the unit, carefully read this manual and keep it for future reference. - This manual provides a detailed description of the precautions that you must pay attention to during use. - Read this manual carefully before using the Wireless Kit to guarantee its proper operation.
10. How to use the app..........21 11. Special functions..........23 12. Remote control features........26 13. Main keys and functions (UI DUCT remote control)........28 14. Remote control screen icons.......29 15. Timer Setting............30 15.1 TIMER ON setting..........30 15.2 TIMER OFF setting.
1. SAFETY PRECAUTIONS. WARNING: • Read the safety precautions carefully before installing the unit. • Below are important safety guidelines to be complied with: - Applicable operating system: IOS, Android (IOS 12, Android 11.0 or higher). NOTE: • Due to the variety of operating systems and their versions and the possibility of particular and unpredictable circumstances occurring, compatibility with all devices cannot be guaranteed.
Page 5
App screen might not be the same: be careful therefore not to get confused. NOTE: • Immergas will not be responsible for any problems and/or criticality caused by the Internet or Wi-fi router.
2. DOWNLOAD AND INSTALLATION OF THE APP. WARNING: • The following QR codes have been provided to be able to download our APP called “CLIMAsmart” Android users. Scan the dedicated QR code or go to Google Play, search for the “CLIMAsmart” app and download it. IOS users.
3. INSTALLATION ACCESSORIES. Select the installation point. Do not install this kit in the presence of combustible oil, sulphurous vapour or gases, as otherwise the product could deform and cause the system to malfunction. Options prior to installation. Check that the following components are included in the package. Description Q.ty Notes...
4. INSTALLATION PROCEDURE. 4.1 Smart port structure dimension. 4.2 Wiring diagram. Insertion of main board CN 40 or CN49 or other ports Only applicable to WF-60A1 black black yellow yellow brown brown 4-pole shielded cable, length Indoor unit main board Smart port depending on installation...
4.3 Wiring connection diagram. Indoor unit Extension main board 4-pole shielded cable Ferrite Ferrite already present in smart port Connection cables unit - Connect the male connector of the connection cables unit to the dedicated connection on the main board of the machine (Indoor unit), then connect the other side to the 4-pole shielded cable coming from the Small port.
4.5 Wall fixing diagram (with hidden cables). For wall mounting, fix the lower part to the wall by means of the 3 screws and plugs (M4x20). Lower plate Screws (M4x20) 4.6 Insert the USB stick. Insert the USB Wi-fi stick into the USB port of the Small port, exerting slight pressure.
4.7 Electrical connection. A. For installation with cables visible, there can be two outlet positions, upper and lower. Cable outlet upper side Cable outlet lower side B. For installation with cables recessed in the wall, remove the pre-ducted area in the lower part and connect to the cables coming out of the wall.
4.8 Smart port connection. Sealant Sealant Bend the cable Bend the cable WARNING: • Do not allow the ingress of water into the Smart port. • Use the sealant to seal the connectors of the cables during installa- tion. During installation, leave the connection cable long enough for easy removal of the Small part during maintenance.
5. TECHNICAL SPECIFICATIONS. Model WI-FI KIT UI DUCT UI SP (EU-OSK105) Standard Wi-fi IEEE 802.11 b/g/n Software Version V 11.34.7 Type of antenna External omni-directional antenna Wi-fi frequency 2.4 G Maximum power transmitted <20 dBM Operating temperature 0°C ~ 45°C...
6. USER REGISTRATION. • Make sure that the mobile device is connected to the wireless router and that the router is already connected to the Internet before performing user registration. • If you’ve forgotten the password, press “Password forgotten?” and follow the procedure indicated on the App.
7. PREPARATION FOR NETWORK CONFIGURATION. • You must disconnect from any other network in the vicinity and make sure that the Android or IOS device connects to the Wi-Fi network you want to configure. • Make sure that the Wi-fi function of the Android or IOS device works properly and can automatically reconnect to the original Wi-Fi network.
Page 16
Make sure that your mobile device is already connected to the Wi-Fi network you want to use. Make sure that the air conditioner is properly powered. Model AP mode Instructions UI DUCT Remote control Press the ‘LED’ key on the remote control 7 straight times, within 10 seconds, until you see the LED in UI SP Remote control the Small Port flashing.
8. NETWORK CONFIGURATION (AUTOMATIC METHOD). Make sure that the air conditioner is in AP mode, as shown on the previous page. 2. Wait for the device search, 3. Select the name of the 1. Press “ ” then click to add it home network you want to connect the air conditioner to and enter the password...
Page 18
4. Wait for it to connect 5. Configuration 6. The device has been to the network successful. configured successfully. You may now modify the You can now see the default name of the air device on the main screen. conditioner.
9. NETWORK CONFIGURATION (MANUAL METHOD). If automatic configuration, shown on the previous page, fails, perform manual configuration. 2. Select the name of 3. Press the ‘LED’ key 1. Manually select the the home network on the remote control type of product you want to connect 7 straight times, the air conditioner...
Page 20
4. The air conditioner displays 5. The device has been a temporary Wi-Fi network, configured successfully, you called ‘net_ac_xxxx’ , which may now modify the name of you may connect to with your the air conditioner. mobile phone, by entering the password ‘12345678’...
10. HOW TO USE THE APP. Make sure that the air conditioner is connected to the home Wi-Fi network (see previous paragraph). 3. The available functions 2. Choose the air are displayed on the air conditioner to be 1. Login conditioner screen controlled...
Page 22
Operating mode. The available modes are: Cooling Dehumidification Ventilation Automatic Central heating 1. Cooling 2. Dehumidification 3. Ventilation 4. Automatic 5. Central heating...
11. SPECIAL FUNCTIONS. Weekly schedule. You may set the weekly schedule of the air conditioner so that it switches on and off automatically. 1. Press ‘ ’ to 2. List of schedules 3. Setting a single schedule modify them...
Page 24
Sleep curve. It is possible to set a sleep curve that takes into account the temperature and speed of the fan during the night, limiting noise and increasing air-conditioning comfort. The sleep curve can only be activated in central heating and cooling mode. 1.
Page 25
(UI SP). If a command/modification is entered by (UI DUCT) or (UI SP) remote control, it will be received by the air conditioner and then by the App; on the contrary, if the command/modification is sent by the App,...
12. REMOTE CONTROL FEATURES. The remote control in this kit allows you to access the configuration mode of the Wi-fi (AP mode), the relative Wi-fi reset, and the configuration of the air conditioner on/off timer. All other functions are already included in the App. Model RG51B/E Rated Voltage...
Page 27
NOTE: To achieve best performance of the product: • Do not mix old and new batteries or batteries of different types. • If the device is not used for over 2 months, remove the batteries from the remote control. TIPS ON USING THE REMOTE CONTROL. The remote control works properly when activated within 8 m from the air conditioner.
13. MAIN KEYS AND FUNCTIONS (UI DUCT REMOTE CONTROL). TEMP. TEMP. Decreases the temperature Dimunisce la temperatura di Increases the temperature by Incrementa la temperatura by 1°C. 1°C. 1°C. di 1°C. The minimum temperature La temperatura minima è di...
14. REMOTE CONTROL SCREEN ICONS. The following information is displayed when the remote control is on. COOL AUTO AUTO HEAT Display of transmitted data. Visualizzazione dei dati trasmessi. COOL HIGH Displays when the remote control is on. Visualizza quando il telecomando è acceso. HEAT Displays when TIMER ON is set.
15. TIMER SETTING. TIMER ON/OFF: Sets the time after which the air conditioner switches on/off automatically. 15.1 TIMER ON setting. Premere il tasto TIMER ON Press TIMER ON key to start the Press the Time up or down key several Premere il tasto Temp.
15.3 Examples of TIMER ON and TIMER OFF settings. Remember that the time periods set for both functions refer to hours after the current time. xn xn TIMER OFF TIMER ON Unit turns Unit turns Timer starts For example, if the current timer reads 1PM Ad esempio, se il timer corrente segna with the above settings, the unit will switch le 13:00 con le impostazioni sopra...
Page 32
Models of wireless modules: EU-OSK105 IC: 24951-MZNA21 The manufacturer Immergas declares that the device complies with Directive 2014/53/EU. Only use the device according to the instructions provided. The manufacturer shall not be held liable in case of modifications or interventions not authorised by the manufacturer himself.
Need help?
Do you have a question about the UI DUCT and is the answer not in the manual?
Questions and answers