Summary of Contents for BITMAIN ANTMINER 17 Series
Page 1
Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to Bitmain's terms and conditions of sale supplied at the time of order acknowledgment.
Page 2
Bitmain does not warrant or represent that any license, either express or implied, is granted under any Bitmain patent right, copyright or other Bitmain intellectual property right relating to any combination, machine, or process in which Bitmain products or services are used.
S17, S17 Pro, T17 Server Installation Guide Table of Contents 1. Overview..............................4 1.1 S17, S17 Pro, T17 Server Components....................5 1.2 Specifications............................. 7 2. Setting Up the Server..........................17 3. Configuring the Server..........................19 4. Monitoring Your Server..........................21 5. Administering Your Server........................23 5.1 Checking Your Firmware Version.....................23 5.2 Upgrading Your System........................24 5.3 Modifying Your Password........................
1. Overview The S17, S17 Pro, T17 servers are Bitmain’s newest versions in the 17 server series. Power supply APW9 is part of S17, S17 Pro, T17 servers. All S17, S17 Pro, T17 servers are tested and configured prior to shipping to ensure easy set up. Here takes...
S17, S17 Pro, T17 Server Installation Guide 1.Overview S17, S17 Pro, T17 Server Components The main components and controller front panel of S17, S17 Pro, T17 servers are shown in the following figure (here takes pictures of S17 server as examples): ‐...
Page 6
S17, S17 Pro, T17 Server Installation Guide 1.Overview APW9 Power Supply: Note: 1.Power supply APW9 is part of S17, S17 Pro, T17 servers. For detailed parameters, please refer to the specifications below. 2.Additional two power cords are needed. ‐ 6 ‐...
S17, S17 Pro, T17 Server Installation Guide 1.Overview 1.2 Specifications Model No.: 240‐Aa Version: S17‐53T Value Product Glance Low Power Normal Crypto Algorithm/Coins SHA256/BTC/BCH Hashrate, TH/s 35~50.00 53.00 , Watt Reference power on wall 1470~2100 2385 Reference power efficiency on wall @25°C, J/TH 42.00 45.00 Value...
Page 8
S17, S17 Pro, T17 Server Installation Guide 1.Overview Server Size (Length*Width*Height, w/o 298.2*178.0*296.6 (2‐1) package),mm (2‐2) Net weight, kg 9.50 (2‐3) Noise, dBA @25°C Environmental Requirements Operation temperature,°C Storage temperature,°C ‐20 Operation humidity, RH(no condensation) Notes: (1‐1) In Low Power Mode, Max Hashrate is about Typ Hashrate *103% (1‐2) Min condition: 25°C, min J/TH, typical Hashrate Max condition: 40°C, max J/TH, max Hashrate...
Page 9
S17, S17 Pro, T17 Server Installation Guide 1.Overview Model No.: 240‐Aa Version: S17‐56T Value Product Glance Low Power Normal Crypto Algorithm/Coins SHA256/BTC/BCH Hashrate, TH/s 35.00~50.00 56.00 , Watt Reference power on wall 1470~2100 2520 Reference power efficiency on wall @25°C, J/TH 45.00 42.00.
Page 10
S17, S17 Pro, T17 Server Installation Guide 1.Overview (2‐3) Noise, dBA @25°C Environmental Requirements Operation temperature,°C Storage temperature,°C ‐20 Operation humidity, RH(no condensation) Notes: (1‐1) In Low Power Mode, Max Hashrate is about Typ Hashrate *103% (1‐2) Min condition: 25°C, min J/TH, typical Hashrate Max condition: 40°C, max J/TH, max Hashrate (1‐3) Caution: Wrong input voltage may probably cause server damaged...
Page 11
S17, S17 Pro, T17 Server Installation Guide 1.Overview Model No.: 240‐Aa Version: S17 Pro‐50T Value Product Glance Normal Low Power Turbo Crypto Algorithm/Coins SHA256/BTC/BCH Hashrate, TH/s 36~48.00 50.00 50~62.00 , Watt Reference power on wall 2250~2790 1296~1728 1975 Reference power efficiency on wall @25°C, J/TH 39.50 36.00.
Page 12
S17, S17 Pro, T17 Server Installation Guide 1.Overview Quantity of hash chips Quantity of hash boards Networking connection mode RJ45 Ethernet 10/100M Server Size (Length*Width*Height, w/o 298.2*178.0*296.6 (2‐1) package),mm (2‐2) Net weight, kg 9.50 (2‐3) Noise, dBA @25°C Environmental Requirements Operation temperature,°C Storage temperature,°C ‐20...
Page 13
S17, S17 Pro, T17 Server Installation Guide 1.Overview Model No.: 240‐Aa Version: S17 Pro‐53T Value Product Glance Low Power Normal Turbo Crypto Algorithm/Coins SHA256/BTC/BCH Hashrate, TH/s 36~48.00 53~62.00 53.00 , Watt Reference power on wall 1296~1728 2094 2385~2790 Reference power efficiency on wall @25°C, J/TH 36.00.
Page 14
S17, S17 Pro, T17 Server Installation Guide 1.Overview Hardware Configuration Quantity of hash chips Quantity of hash boards Networking connection mode RJ45 Ethernet 10/100M Server Size (Length*Width*Height, w/o 298.2*178.0*296.6 (2‐1) package),mm (2‐2) Net weight, kg 9.50 (2‐3) Noise, dBA @25°C Environmental Requirements Operation temperature,°C Storage temperature,°C...
Page 15
S17, S17 Pro, T17 Server Installation Guide 1.Overview Model No.: 240‐Aa Version: T17‐40T Value Product Glance Crypto Algorithm/Coins SHA256/BTC/BCH Hashrate, TH/s 40.00 , Watt Reference power on wall 2200 Reference power efficiency on wall @25°C, J/TH 55.00 Value Detailed Characteristics Hashrate &...
Page 16
S17, S17 Pro, T17 Server Installation Guide 1.Overview Notes: (1‐1) Min condition: 25°C, min J/TH, typical Hashrate Max condition: 40°C, max J/TH, max Hashrate (1‐2) Caution: Wrong input voltage may probably cause server damaged (1‐3) Typ condition: min reference power, typical AC input voltage Max condition: max reference power, min AC input voltage (2‐1) Including PSU size...
Setting Up the Server To set up the server: The file IPReporter.zip is supported by Microsoft Windows only. Go to the following site: https://shop.bitmain.com/support.htm?pid=00720160906053730999PVD2K0vz0693 2. Download the following file: IPReporter.zip. 3. Extract the file. The default DHCP network protocol distributes IP addresses automatically.
Page 18
S17, S17 Pro, T17 Server Installation Guide 2.Setting Up the server 7. On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds). The IP address will be displayed in a window on your computer screen. 8.
S17, S17 Pro, T17 Server Installation Guide 3.Configuring the Server Configuring the Server Setting Up the Pool To configure the server: 1. click General Settings. S17 Server: S17 Pro Server: ‐ 19 ‐...
Page 20
S17, S17 Pro, T17 Server Installation Guide 3. Configuring the Server T17 Server: Note: There are three modes of Hashrate which u may adjust for S17 Pro server: Low Power mode, Normal Mode and Turbo mode (High Performance Mode); two modes for S17 server: Low Power mode and Normal mode.
S17, S17 Pro, T17 Server Installation Guide 4. Monitoring Your Server Monitoring Your server To check the operating status of your server: 1. Click the status marked below. Here is an example of S17‐53T server running under Normal mode: Here is an example of S17 Pro‐ 53T server running under Turbo mode: ‐...
Page 22
S17, S17 Pro, T17 Server Installation Guide 4. Monitoring Your Server Here is an example of T17‐40T server: Note: The S17, S17 Pro, T17 servers are with automatic frequency. Firmware will stop running when the Temp (PCB) reaches to 75℃ or Temp(chips) reaches to 100℃,there will be an error message “Fatal Error: Temperature is too high!”...
S17, S17 Pro, T17 Server Installation Guide 5. Administering Your Server 5. Administering Your Server 5.1 Checking Your Firmware Version To check your firmware version: 1. In System, click the Overview tab. 2. File System Version displays the date of the firmware your server uses. In the examples below, the servers are respectively version 20190408 and 20190426.
5.2 Upgrading Your System Make sure that the S17, S17 Pro, T17 servers remain powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair. To upgrade the server’s firmware: 1.
S17, S17 Pro, T17 Server Installation Guide 5. Administering Your Server 4. When the upgrade is completed, the following message appears: 5. Click one of the following options: Reboot ‐ to restart the server with the new firmware. ■ Go Back ‐ to continue mining with the current firmware. The server will load the new firmware next time when it is ■...
S17, S17 Pro, T17 Server Installation Guide Environmental Requirements Please run your server in accordance with the following requirements 1. Basic Environmental Requirements: 1.1. Climatic Conditions: Description Requirement Operating Temperature 0‐40℃ Operating Humidity 10‐90%RH (non‐condensing) Storage Temperature ‐20‐70℃ Storage Humidity 5‐95%RH(non‐condensing)...
Page 27
S17, S17 Pro, T17 Server Installation Guide 2.2 Requirements of Corrosive Gas Corrosive Gas Unit Concentration < 3 < 10 < 1 < 50 < 1 < 500 < 2 Note: ppb (part per billion) refers to the unit of concentration,1ppb stands for the volume ratio of part per billion.
S17, S17 Pro, T17 Server Installation Guide Regulations: FCC Notice (FOR FCC CERTIFIED MODELS): This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Need help?
Do you have a question about the ANTMINER 17 Series and is the answer not in the manual?
Questions and answers