® Tribeca Collection Towel Warmers Installation, Operation & Maintenance Instructions HOMEOWNER: INSTALLER: THANK YOU for selecting MrSteam Towel Warmer, the READ THIS ENTIRE INSTRUCTION MANUAL THOROUGHLY BEFORE perfect addition to bathrooms, family spas, and exercise BEGINNING INSTALLATION. LEAVE THESE INSTRUCTIONS WITH rooms within your home.
® Tribeca Collection Towel Warmers Installation, Operation & Maintenance Instructions WALL PREPARATION Finished Wall Surface • DO NOT mount the Towel Warmer without providing structurally Upper Header (Z) secure upper and lower headers as shown. • DO NOT mount the Towel Warmer directly to sheet rock or any other non-structural surface.
® Tribeca Collection Towel Warmers Installation, Operation & Maintenance Instructions ELECTRICAL CONNECTIONS 1. Assemble the BX cable connector to the BX Cable* wiring box escutcheon as shown. (or greenfield) Wiring Box TO PREVENT SHOCK HAZARD, THE Escutcheon NOTE: NM (non-metallic) cable, if ELECTRICITY MUST BE TURNED OFF AT THE MAIN PANEL permitted by National and Local BX Connector...
® Tribeca Collection Towel Warmers Installation, Operation & Maintenance Instructions ELECTRICAL CONNECTIONS Optional Digital Programmable Timer General: 1. Read the operating instructions provided with the timer. The Towel Warmer requires 120 VAC, 50/60 Hz power. Specific amperage 2. Disconnect power supply prior to installation to prevent electrical shock. needed is listed in the Towel Warmer Specifications Chart on page 1 of this 3.