Feel Good mr steam Fifth Avenue W500 Installation, Operation And Maintenance Manual

Electric & hydronic towel warmers

Advertisement

Quick Links

.
mr
steam
®
________________________________________________________________
Installation, Operation and Maintenance Manual
Fifth Avenue Collection
Electric & Hydronic Towel Warmers
.
mr
_______________________________________________
Model
_______________________________________________
Serial No.
Models W500, W542 H542, W634
W500
W542
IMPORTANT NOTE: As you follow these instructions, you will notice warning and caution symbols.
This blocked information is important for the safe and efficient installation and operation of this Towel Warmer.
These are types of potential hazards that may occur during this installation and operation:
!
WARNING
states a hazard
may cause serious injury or death if
precautions are not followed.
Electric Towel Warmers
Models: W500, W542, H542, W634
steam
®
H542
W634
!
CAUTION
signals a situation
where minor injury or product damage
may occur if you do not follow instructions.
Installation and Operating Instructions
Feel Good Inc.

Table of Contents

_____________________
Electric Models
Wall Preparation ....................................3
Mounting ...............................................4
Models 542, 634 .................................5
Model 500 ..........................................6
Electrical Connections ....................... 7-8
Digital Programmable Timer .................8
___________________________________
General Information ..............................9
Pre-Installation & Wall Prep ................10
Plumbing Preparation ..........................11
Hook-up and Installation ............... 11-12
Operation & Maintenance ...................12
IMPORTANT NOTE: This highlights
information that is especially relevant
to a problem-free installation.
103852
1.15
pur
rev

Advertisement

Table of Contents
loading

Summary of Contents for Feel Good mr steam Fifth Avenue W500

  • Page 1: Table Of Contents

    Installation and Operating Instructions ________________________________________________________________ Installation, Operation and Maintenance Manual Fifth Avenue Collection Electric & Hydronic Towel Warmers Models: W500, W542, H542, W634 steam Feel Good Inc. ® Table of Contents _____________________ _______________________________________________ Electric Models Model General Information & Specifications ...2 _______________________________________________ Wall Preparation ........3...
  • Page 2: General Information & Specifications

    steam ® Electric Towel Warmers Installation and Operating Instructions ________________________________________________________________ HOMEOWNER: INSTALLER: __________________________________________ ______________________________________________________ THANK YOU for selecting Mr.Steam Towel Warmer, the READ THIS ENTIRE INSTRUCTION MANUAL THOROUGHLY perfect addition to bathrooms, family spas, and exercise BEFORE BEGINNING INSTALLATION. LEAVE THESE rooms within your home.
  • Page 3: Wall Preparation

    steam ® Electric Towel Warmers Installation and Operating Instructions ________________________________________________________________ WALL PREPARATION CAUTION • DO NOT mount the Towel Warmer without providing structurally secure headers as shown. Finished wall surface • DO NOT mount the Towel Warmer directly to sheet rock or any other non-structural surface.
  • Page 4: Mounting

    steam ® Electric Towel Warmers Installation and Operating Instructions ________________________________________________________________ MOUNTING MOUNTING DIMENSIONS (inches) MODEL This W 500 ⁄ W 542 ⁄ ⁄ ⁄ ⁄ W 634 ⁄ ⁄ ⁄ ⁄ WARNING Install Towel Warmers in upright position only. Locate with indicator light on bottom as shown.
  • Page 5: Installation Models 542, 634

    steam ® Electric Towel Warmers Installation and Operating Instructions ________________________________________________________________ IMPORTANT: DO NOT LOOSEN SCREWS MODELS W542 & W634 ON TOP OR BOTTOM BRACKETS. LOOSENING SCREWS WILL CAUSE INTERNAL LIQUID TO ESCAPE AND CAUSE PRODUCT DAMAGE. Box Contents • Towel Warmer •...
  • Page 6: Model 500

    steam ® Electric Towel Warmers Installation and Operating Instructions ________________________________________________________________ MODELS W500 TO PREVENT SHOCK HAZARD, BE CERTAIN WARNING THAT ELECTRICITY IS TURNED OFF AT THE MAIN PANEL BEFORE Upper Threaded Flange ANY WIRING IS DONE. Upper Support Bracket Box Contents This •...
  • Page 7: Electrical Connections

    steam ® Electric Towel Warmers Installation and Operating Instructions ________________________________________________________________ ELECTRICAL CONNECTIONS Models W500, W542, W634 TO PREVENT SHOCK HAZARD, BE CERTAIN THAT ELECTRICITY IS TURNED OFF AT THE MAIN PANEL BEFORE ANY WIRING IS DONE. WARNING The towel warmer is an electronically operated device. It must be installed by a licensed electrician in accordance with local code and the National Electric Code (NEC).
  • Page 8: Digital Programmable Timer

    steam ® Electric Towel Warmers Installation and Operating Instructions ________________________________________________________________ ELECTRICAL SPECIFICATIONS Field Wired Models: W500, W542, W634 Electrical Connections WARNING TO PREVENT SHOCK HAZARD, BE CERTAIN THAT ELECTRICITY IS TURNED OFF AT THE MAIN PANEL BEFORE ANY WIRING IS DONE. All wiring must conform to National Electrical and Local Codes.
  • Page 9: Hydronic Model

    steam ® Hydronic Towel Warmers Installation and Operating Instructions ________________________________________________________________ HYDRONIC MODEL H542 WARNING Suitable only for closed loop non-potable hot water systems. Tighten Towel Warmer unions only. Do not turn valves as leaking may result WARNING Do not use with water over 158 degrees F. (7o˚...
  • Page 10: Pre-Installation & Wall Prep

    steam ® Hydronic Towel Warmers Installation and Operating Instructions ________________________________________________________________ STEP 1: PRE-INSTALLATION WALL PREPARATION A. Select Installation Site: Make certain there is ample clear- CAUTION ance on both sides and back of the Towel Warmer. • DO NOT mount the Towel Warmer without providing NOTE: This unit is supplied with the proper hardware for structurally secure headers as shown.
  • Page 11: Plumbing Preparation

    steam ® Hydronic Towel Warmers Installation and Operating Instructions ________________________________________________________________ PLUMBING PREPARATION • If the eccentric coupling is used, a female 1/2 1/2 inch NPT coupling or thread-to-sweat adapter should be flush with the finished face of the wall. • If the eccentric coupling is not used a male 3/4 F lush NPT pipe, coupling or thread to sweat adapter shall be 1/2 an inch beyond the finished face of...
  • Page 12: Operation & Maintenance

    steam ® Hydronic Towel Warmers Installation and Operating Instructions ________________________________________________________________ VALVE INSTALLATION STEP 3: INSTALLATION (cont.) B. Valve Installation: 1. Place a washer between the threaded portion of the valve and the Towel Warmer union. carefully tighten Finished Upright tube face of wall the union to secure the valve to the Towel Warmer.

Table of Contents