Fluke 80J-10 Instruction Sheet
Fluke 80J-10 Instruction Sheet

Fluke 80J-10 Instruction Sheet

Ac/dc current shunt

Advertisement

Quick Links

= LUKE
Instruction Sheet
80J-10
AC/DC Current Shunt
INTRODUCTION
The Model 80J-10 Current Shunt allows any voltmeter
with % inch center banana jacks and 0.1 mV resolution
to be used to measure up to 10 amps continuous (20
amps for periods not exceeding one minute) DC to 10
kHz
at an accuracy
of +0.25%
in excess
of the
voltmeter accuracy.
SPECIFICATIONS
Shunt: 10 amps at 100 mV
Accuracy (18°C to 28°C):
DC to 10 kHz: +0.25%
10 kHz- 1000 kHz: Rising to 1 dB at 100 kHz typical
Temperature Coefficient: 0.005%/°C
Inductance: 8.3 nh in series w/0.010 shunt
Overload: Up to one minute at 20A with a 1⁄4 duty
cycle for recovery after currents between 10 and 20A.