Summary of Contents for Dantherm Cooling ThermoFlow Series
Page 1
ThermoFlow Series ® Product User Manual DANTHERMCOOLING.COM TECHSUPPORT@DANTHERMCOOLING.COM 864-595-9800671 SPRINGFIELD ROAD SPARTANBURG, SOUTH CAROLINA 29303...
The target group for this service manual are and improvements to the product and the the technicians who install and maintain the service manual at any time without prior notice ThermoFlow Series units, as well as users of the or obligation. unit. TABLE OF CONTENTS UNPACKING SAFETY | WARNING .
Hard hat | Safety shoe | Hearing protection | hardware are firmly secured before leaving Cut resistant gloves | Face shield | Proper work installation. attire (long sleeve shirt and long pants) • All cable and connectors must conform to UL standards THERMOFLOW SERIES PRODUCT MANUAL...
The control is handled by the supplied power. energy consumption. It will also supply either a normally closed (NC) or normally open (NO) alarm signal for fan fault, or high temperature THERMOFLOW SERIES PRODUCT MANUAL...
PRODUCT DESCRIPTION PROUCT DESCRIPTION The Thermoflow series is designed to control the internal temperature of an enclosure. By removing dissipated heat from inside the structure and is designed to maintain accurate Warm Air temperatures for electronic equipment. Exhaust IMPORTANT Indoor Dantherm Cooling Inc.
• Utilize an appropriate and safe lifting device. • Mount the Thermoflow to the cabinet by using the mounting hook, which supports the weight of the unit. The hook grabs the cutout opening on the cabinet panel. THERMOFLOW SERIES PRODUCT MANUAL...
2. Connect the ThermoFlow units ground this purpose. terminal to enclosure grounding. 3. All power supply connections are to be secured with an external disconnection device, as well as over current protected. 4. Connect any needed accessories. THERMOFLOW SERIES PRODUCT MANUAL...
STEP INT. FAN EXT. FAN ALARM DURATION Activated Solid 30 sec. Activated Flashing 30 sec. Activated Flashing 30 sec. 100% Activated Flashing 30 sec. 100% 100% Activated Flashing 30 sec. Normal Flashing 15 sec. THERMOFLOW SERIES PRODUCT MANUAL...
A sensor fault has occured. The fans should operate at full speed until this is corrected. THE RED LED IS FLASHING Check the sensor or cabinet temperature. THE RED LED IS SOLID A fan fault has occured. Check the fan wiring or the fan. THERMOFLOW SERIES PRODUCT MANUAL...
°F [°C] RANGE [-40 to 65] MAXIMUM AIRFLOW CFM [m3/hr] [1203] NOISE 1.5M DISTANCE INPUT VOLTAGE Volts 48 VDC CURRENT Amps APPROVALS SA12349 (UL) NEMA Aluzink Steel, Stainless Optional CONSTRUCTION Textured Powder Coat, Color Options Available THERMOFLOW SERIES PRODUCT MANUAL...
Page 14
UNIT OVERVIEW ThermoFlow® 175 19.5 1056 5° 41.6 1043 41.1 17.1 37.6 16.7 28.2 24.4 1235 18.8 48.6 16.5 19.7 15.7 14.5 NOTES: 1) UNITS = MM [IN] 2) STEP FILES AVAILABLE UPON REQUEST THERMOFLOW SERIES PRODUCT MANUAL...
Page 15
[°C] RANGE [-40 to 65] 1150 MAXIMUM AIRFLOW CFM [m3/hr] [1950] NOISE 1.5M DISTANCE INPUT VOLTAGE Volts 48 VDC CURRENT Amps APPROVALS SA12349 (UL) NEMA Aluzink Steel, Stainless Optional CONSTRUCTION Textured Powder Coat, Color Options Available THERMOFLOW SERIES PRODUCT MANUAL...
Page 16
UNIT OVERVIEW ThermoFlow® 230 19.5 1056 5° 41.6 1043 41.1 17.1 37.6 16.7 28.2 24.4 1235 18.8 48.6 16.5 19.7 15.7 14.5 NOTES: 1) UNITS = MM [IN] 2) STEP FILES AVAILABLE UPON REQUEST THERMOFLOW SERIES PRODUCT MANUAL...
Page 17
MAXIMUM AIRFLOW CFM [m3/hr] [2350] NOISE 1.5M DISTANCE INPUT VOLTAGE Volts 48 VDC 480 VAC 3 Ø CURRENT Amps APPROVALS SA12349 (UL) In Process NEMA Aluzink Steel, Stainless Optional CONSTRUCTION Textured Powder Coat, Color Options Available THERMOFLOW SERIES PRODUCT MANUAL...
Water is NOT recommended. Reconnect power after service. SPARE PARTS A number of spare and replacement parts are available from Dantherm Cooling. Please contact technical support for more information at: technicalsupport@danthermcooling.com. THERMOFLOW SERIES PRODUCT MANUAL...
RIGHTS WHICH VARY FROM STATE TO STATE. damage in transportation, lack of normal SOME STATES DO NOT ALLOW LIMITATIONS preventive maintenance, or other events beyond OR EXCLUSIONS, SO THE ABOVE LIMITATIONS DANTHERM’s control. AND EXCLUSIONS MAY NOT APPLY TO YOU. THERMOFLOW SERIES PRODUCT MANUAL...
Recycling: The unit should be recycled prior to a RMA number being issued: according to national rules and procedures to • Dantherm Cooling, Inc. part number(s) of protect the environment. Please consult your product to be returned local authorities for further information.
Page 21
DANTHERMCOOLING.COM TECHSUPPORT@DANTHERMCOOLING.COM 864-595-9800 671 SPRINGFIELD ROAD SPARTANBURG, SOUTH CAROLINA 29303...
Need help?
Do you have a question about the ThermoFlow Series and is the answer not in the manual?
Questions and answers