Copying of this service manual, or part of it, is HexFlow heat exchanger units. Please see the forbidden without prior written permission from table of contents below for further information Dantherm Cooling Inc. about the sections of this manual. RESERVATIONS TARGET GROUP...
UNPACKING SAFETY UNPACKING, HANDLING, AND • The heat exchanger is UL recognized INSPECTION and tested to UL1995. It will comply where necessary with the safety requirements as Thank you for purchasing a Dantherm HexFlow defined in UL1995. heat exchanger. Please carefully review all handling and installation instructions.
MODEL IDENTIFICATION MODEL IDENTIFICATION HF-45-230-T1 CAPACITY OPTIONS 17 - 17 W/°F L - EXTERNAL PLUG 22 - 22 W/°F0 M - STAINLESS STEEL COVER VOLTAGE 26 - 26 W/°F PXX - NON STANDARD PAINT COLOR 115 - 115 volt / single phase 35 - 35 W/°F S - SPEED CONTROLLER 230 - 230 volt / single phase...
PRODUCT DRAWINGS VIEW 1 PART DESCRIPTION Cabinet Air IN Cabinet Air Out Ambient Air IN Ambient Air Out Mounting Hook Installation Gasket VIEW 2 PART DESCRIPTION Cabinet Air IN Cabinet Air OUT Installation Gasket Mounting Face Mounting Flange HEXFLOW PRODUCT USER MANUAL...
MOUNTING AND OPERATION MOUNTING & OPERATION • The electrical circuit should be protected by a slow blow breaker or fuse. Refer to section 5 in • The enclosure shall be checked for correctness this manual for fuse/breaker rating. of cutouts, mounting holes and electrical supply. •...
WIRING DIAGRAMS The following schematics are of standard products only. Wiring schematics for options or custom products are available directly from Dantherm Cooling. AC Voltage Diagram: All Models DC Voltage Diagram: All Models without speed control HEXFLOW PRODUCT USER MANUAL...
Page 12
WIRING DIAGRAMS DC Voltage Diagram with HX2 Speed Control (up to batch 130601) DC Voltage Diagram with HX2 Speed Control (batch 130601 and newer) HEXFLOW PRODUCT USER MANUAL...
WARRANTY: This warranty does not cover damages or repairs caused by improper installation, misuse of the product, negligent servicing, improper DANTHERM COOLING, INC. (“DANTHERM”) applications, unauthorized modifications, limited warranty extends to the original improper electrical supply, failure to follow purchaser only of any DANTHERM heat manufacturer’s instructions and rating plate...
RMA number. • The following information must be provided prior to a RMA number being issued: • Dantherm Cooling, Inc. part number(s) of product to be returned. • Dantherm Cooling, Inc. serial number(s) of product to be returned.
Page 15
DANTHERMCOOLING.COM TECHSUPPORT@DANTHERMCOOLING.COM 864-595-9800 671 SPRINGFIELD ROAD SPARTANBURG, SOUTH CAROLINA 29303...
Need help?
Do you have a question about the HexFlow HF17115 and is the answer not in the manual?